This study analyzes the repeatability, reproducibility and accuracy of a new hyperspectral system based on a pushbroom sensor as a means of measuring spectral features and color of materials and objects. The hyperspectral system consisted of a CCD camera, a spectrograph and an objective lens. An additional linear moving system allowed the mechanical scanning of the complete scene. A uniform overhead luminaire with daylight configuration was used to irradiate the scene using d:45 geometry. We followed the guidelines of the ASTM E2214-08 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments that define the standards and latest multidimensional procedures. The results obtained are analyzed in-depth and compared to those recently reported by other authors for spectrophotometers and multispectral systems. It can be concluded that hyperspectral systems are reliable and can be used in the industry to perform spectral and color readings with a high spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New color-measuring instruments known as multiangle spectrophotometers have been recently created to measure and characterize the goniochromism of special-effect pigments in many materials with a particular visual appearance (metallic, interference, pearlescent, sparkle, or glitter). These devices measure the gonioapparent color from the spectral relative reflectance factor and the L*a*b* values of the sample with different illumination and observation angles. These angles usually coincide with requirements marked in American Society for Testing and Materials (ASTM) and Deutsches Institut Für Normung standards relating to the gonioapparent color, but the results of comparisons between these instruments are still inconclusive. Therefore, the main purpose of this study is to compare several multiangle spectrophotometers at a reproducibility level according to ASTM E2214-08 guidelines. In particular, we compared two X-Rite multi-gonio spectrophotometers (MA98 and MA68II), a Datacolor multi-gonio spectrophotometer (FX10), and a BYK multi-gonio spectrophotometer (BYK-mac). These instruments share only five common measurement geometries: 45° × −30° (as 15°), 45° × −20° (as 25°), 45° × 0° (as 45°), 45° × 30° (as 75°), 45° × 65° (as 110°). Specific statistical studies were used for the reproducibility comparison, including a Hotelling test and a statistical intercomparison test to determine the confidence interval of the partial color differences ΔL*, Δa*, Δb*, and the total color difference ΔE*ab. This was conducted using a database collection of 88 metallic and pearlescent samples that were measured 20 times without the replacement of all the instruments. The final findings show that in most measurement geometries, the reproducibility differences between pairs of instruments are statistically significant, although in general, there is a better reproducibility level at certain common geometries for newer instruments (MA98 and BYK-mac). This means that these differences are due to systematic or bias errors (angle tolerances for each geometry, photometric scales, white standards, etc.), but not exclusively to random errors. However, neither of the statistical tests used is valid to discriminate and quantify the detected bias errors in this comparison between instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.