6 resultados para Reinforcement room

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report electrical conductance measurements of Bi nanocontacts created by repeated tip-surface indentation using a scanning tunneling microscope at temperatures of 4 and 300 K. As a function of the elongation of the nanocontact, we measure robust, tens of nanometers long plateaus of conductance G0=2e2/h at room temperature. This observation can be accounted for by the mechanical exfoliation of a Bi(111) bilayer, a predicted quantum spin Hall (QSH) insulator, in the retracing process following a tip-surface contact. The formation of the bilayer is further supported by the additional observation of conductance steps below G0 before breakup at both temperatures. Our finding provides the first experimental evidence of the possibility of mechanical exfoliation of Bi bilayers, the existence of the QSH phase in a two-dimensional crystal, and, most importantly, the observation of the QSH phase at room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work is to study the dynamic behavior of a pedestrian bridge in Alicante, Spain. It is a very slender footbridge with vertical and horizontal vibration problems during the passage of pedestrians. Accelerations have been recorded by accelerometers installed at various locations of the bridge. Two scenarios, in free vibration (after the passage of a certain number of pedestrians on the bridge) and forced vibration produced by a fixed number of pedestrians walking on the bridge at a certain speed and frequency. In each test, the effect on the comfort of the pedestrians, the natural frequencies of vibration, the mode shapes and damping factors have been estimated. It has been found that the acceleration levels are much higher than the allowable by the Spanish standards and this should be considered in the restoration of the footbridge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In relation to the current interest on gas storage demand for environmental applications (e.g., gas transportation, and carbon dioxide capture) and for energy purposes (e.g., methane and hydrogen), high pressure adsorption (physisorption) on highly porous sorbents has become an attractive option. Considering that for high pressure adsorption, the sorbent requires both, high porosity and high density, the present paper investigates gas storage enhancement on selected carbon adsorbents, both on a gravimetric and on a volumetric basis. Results on carbon dioxide, methane, and hydrogen adsorption at room temperature (i.e., supercritical and subcritical gases) are reported. From the obtained results, the importance of both parameters (porosity and density) of the adsorbents is confirmed. Hence, the densest of the different carbon materials used is selected to study a scale-up gas storage system, with a 2.5 l cylinder tank containing 2.64 kg of adsorbent. The scale-up results are in agreement with the laboratory scale ones and highlight the importance of the adsorbent density for volumetric storage performances, reaching, at 20 bar and at RT, 376 g l-1, 104 g l-1, and 2.4 g l-1 for CO2, CH4,and H2, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pd and bimetallic Ni50Pd50 nanoparticles protected by polyvinylpyrrolidone (PVP) have been synthesized by the reduction-by-solvent method and deposited on single wall carbon nanotubes (SWCNTs) to be tested as H2 sensors. The SWCNTs were deposited by drop casting from different suspensions. The Pd nanoparticles-based sensors show a very reproducible performance with good sensitivity and very low response times (few seconds) for different H2 concentrations, ranging from 0.2% to 5% vol. H2 in air at atmospheric pressure. The influence of the metal nanoparticle composition, the quality of SWCNTs suspension and the metal loading have been studied, observing that all these parameters play an important role in the H2 sensor performance. Evidence for water formation during the H2 detection on Pd nanoparticles has been found, and its repercussion on the behaviour of the assembled sensors is discussed. The sensor preparation procedure detailed in this work has proven to be simple and reproducible to prepare cost-effective and highly efficient H2 sensors that perform very well under real application conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel magnetic nanoparticle-supported oxime palladacycle catalyst was successfully prepared and characterized. The magnetically recoverable catalyst was evaluated in the room temperature Suzuki–Miyaura cross-coupling reaction of aryl iodides and bromides in aqueous media. The catalyst was shown to be highly active under phosphine-free and low Pd loading (0.3 mol%) conditions. The catalyst could be easily separated from the reaction mixture using an external magnet and reused for six consecutive runs without significant loss of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe the documentary quality of two records related to patient safety in the operating room and to identify differences between information related to infection and hospitalization. Methods: Comparative study based on two cross sections, conducted with 3,033 patients who had been hospitalized for more than 24 hours in an Orthopedics and Traumatology Center. Sociodemographic and clinical data, as well as information provided in forms were compared. Postoperative infection was identified as an adverse event. Results: There was a significant correlation between hospitalization days and the total number of diagnoses collected (Pearson=0.328; p<0.001). When diagnoses and infections were grouped together, a significant value was found between closed fractures and infection (p=0.001). Conclusion: Differences in the degree of completion were observed between the two records. There were no differences between adverse events.