15 resultados para Reinforced concrete sandwich panels

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last few decades, the use of cast in situ reinforced concrete sandwich panels for the construction of low- to mid-rise buildings has become more and more widespread due to several interesting properties of this construction technique, such as fast construction and high thermal and acoustic performances. Nonetheless the level of knowledge of the structural behavior of systems made of squat reinforced concrete sandwich panels is still not so consolidated, especially with reference to the seismic response, due to the lack of experimental studies. In recent years, while various experimental tests have been conducted on single panels aimed at assessing their seismic capacity, only few tests have been carried out on more complex structural systems. In this paper, the experimental results of a series of shaking-table tests performed on a full-scale 3-storey building are presented in detail. The main goal is to give to the scientific community the possibility of develop independent interpretation of these experimental results. An in-depth interpretation of the discrepancies between the analytical predictions and the experimental results is beyond the objective of this paper and is still under development. Nonetheless, preliminary interpretations indicate that both the stiffness and the strength of the building under dynamic excitation appear quite superior with respect to those expected from the results of previous pseudo-static cyclic tests conducted on simple specimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research, strain-sensing and damage-sensing functional properties of cement composites have been studied on a conventional reinforced concrete (RC) beam. Carbon nanofiber (CNFCC) and fiber (CFCC) cement composites were used as sensors on a 4 m long RC beam. Different casting conditions (in situ or attached), service location (under tension or compression) and electrical contacts (embedded or superficial) were compared. Both CNFCC and CFCC were suitable as strain sensors in reversible (elastic) sensing condition testing. CNFCC showed higher sensitivities (gage factor up to 191.8), while CFCC only reached gage factors values of 178.9 (tension) or 49.5 (compression). Furthermore, damage-sensing tests were run, increasing the applied load progressively up to the RC beam failure. In these conditions, CNFCC sensors were also strain sensitive, but no damage sensing mechanism was detected for the strain levels achieved during the tests. Hence, these cement composites could act as strain sensors, even for severe damaged structures near to their collapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article summarizes research on the application of a conductive cement paste as an anode in the now classical technique of electrochemical extraction of chlorides applied to a concrete structural element by spraying the paste on the surface of a concrete structural element, a pillar. Sprayed conductive cement paste, by adding graphite powder, is particularly useful to treat sizable vertical surfaces such are structural supports. Outcomes indicate that this kind of anode not only provides electrochemical chloride removal with similar efficiency, but also is able to retain moisture even without the use of a continuous dampening system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the research carried out regarding the application of cathodic protection (CP) and cathodic prevention (CPrev), in some cases with a pre-treatment of electrochemical chloride extraction (ECE), on representative specimens of reinforced concrete structures, using an anodic system consisting of a graphite-cement paste applied as a coating on the surface. The aim of this research is to find out the competence of this anode for the aforementioned electrochemical treatments. The efficiency of this anode has been clearly demonstrated, as well as its capability to apply a combined process of ECE and after CP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article shows the research carried out by the authors focused on how the shape of structural reinforced concrete elements treated with electrochemical chloride extraction can affect the efficiency of this process. Assuming the current use of different anode systems, the present study considers the comparison of results between conventional anodes based on Ti-RuO2 wire mesh and a cement-based anodic system such as a paste of graphite-cement. Reinforced concrete elements of a meter length were molded to serve as laboratory specimens, to closely represent authentic structural supports, with circular and rectangular sections. Results confirm almost equal performances for both types of anode systems when electrochemical chloride extraction is applied to isotropic structural elements. In the case of anisotropic ones, such as rectangular sections with no uniformly distributed rebar, differences in electrical flow density were detected during the treatment. Those differences were more extreme for Ti-RuO2 mesh anode system. This particular shape effect is evidenced by obtaining the efficiencies of electrochemical chloride extraction in different points of specimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to study the feasibility of highly conductive carbon fiber reinforced concrete (CFRC) as a self-heating material for ice formation prevention and curing in pavements. Tests were carried out in lab ambient conditions at different fixed voltages and then introduced in a freezer at −15 °C. The specimens inside the freezer were exposed to different fixed voltages when reaching +5 °C for prevention of icing and when reaching the temperature inside the freezer, i.e., −15 °C, for curing of icing. Results show that this concrete could act as a heating element in pavements with risk of ice formation, consuming a reasonable amount of energy for both anti-icing (prevention) and deicing (curing), which could turn into an environmentally friendly and cost-effective deicing method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the so-called Kiss Bridge. This structure resembles a kiss, a subtle touch of structures. The beams have been structurally designed to adapt the Japanese art of paper folding called "origami." The material used for constructing the floating beams is white reinforced concrete in the form of folded shells. The two geometrically different parts have distinct structural behaviors. The length of the main pathway of both structures is over 60 m. The pedestrian bridge crosses an artificial rainwater channel with a skew of 45° with respect to the referred channel. The joint between the cantilever structure and the Y-shaped one is located over the middle of the channel. Each stretch has different transversal sections. The pedestrian bridge is made with prestressed self-compacting reinforced concrete of 60 MPa. The foundation is shallow, comprising footings and footing beams made of 25 MPa conventional concrete. The cantilever structure with its foundations is designed as a semi-integral bridge whereas the Y-shaped one is an integral structure. The dynamic behavior of the structure was carefully studied to ensure that the dynamic loads generated by pedestrians do not cause excessive vibrations, especially to the cantilever structure, which could present dynamic interactions with the pedestrians walking. The bridge was recognized, in the 2014 edition of the fib Awards for Outstanding Concrete Structures, for having made a valuable contribution to the image and promotion of concrete structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este libro de "Apuntes de Hormigón Armado" desarrolla los contenidos relacionados con el cálculo y comprobación de estructuras de edificación convencionales construidas en hormigón armado. Incluye los Estados Límite Últimos (piezas flectadas y flexo-comprimidas, cortante y punzonamiento, inestabilidad en pilares, redistribución limitada de momentos), Estados Límite de Servicio (fisuración y deformaciones instantáneas y diferidas), disposiciones constructivas de armaduras longitudinales y tangenciales y cálculo de elementos de cimentación y contención. La norma de referencia es la Instrucción Española de Hormigón Estructural, EHE-08, aunque también se reseña puntualmente el Eurocódigo 2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presentaciones de los temas que integran los contenidos de la asignatura "Hormigón Armado y Pretensado", impartida en las titulaciones de Ingeniería Técnica de Obras Públicas, Ingeniería Geológica y Grado en Ing. Civil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supuestos prácticos de autoevaluación de la asignatura "Estructuras de Hormigón Armado y Pretensado".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mechanical behaviour of transventilated façades performed by natural stone is necessarily based on the correct execution of both anchoring elements on the stone cladding as in the ones corresponding to the enclosure support, either with brick masonry walls or reinforced concrete walls. In the case studied in the present work, the origin of the damages suffered on the façade of a building located in Alcoy has been analyzed, where the detachment of part of the outer enclosure occurred. This enclosure is a transventilated façade formed by Bateig Blue stone tiles. To this end, “in situ” tests of the anchoring systems employed have been performed, as well as laboratory tests of mechanical characterization of the material and of different types of anchor, comparing these results with those obtained in both the simplified analytical models of continuum mechanics as developed by the Finite Element Method (FEM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El golpe militar de 1936 conducirá a una dura contienda civil. Durante la misma, la Aviación Legionaria Italiana y, en menor medida, la Legión Cóndor bombardeará duramente numerosas ciudades de la costa mediterránea. Para proteger a la población, las Juntas Locales de Defensa Pasiva llevarán a cabo un programa de construcción de refugios antiaéreos sin precedentes hasta entonces. En Alicante serán numerosos los refugios construidos, entre ellos los situados en las plazas de Séneca y del Dr. Balmis, ambas construcciones salen a la luz, tras años de olvido, a raíz de sendos proyectos de remodelación de las zonas en las que se encuentran enclavados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study is in the frame of the cooperative line that several Spanish Universities and other foreign partners started with the Haitian government in 2010. According to our studies (Benito et al. in An evaluation of seismic hazard in La Hispaniola, after the 2010 Haiti earthquake, 33rd General Assembly of the European Seismological Commission, Moscow, Russia, 2012) and recent scientific literature, the earthquake hazard in Haiti remains high (Calais et al. in Nat Geosci 3:794–799, 2010). In view of this, we wonder whether the country is currently ready to face another earthquake. In this sense, we estimated several damage scenarios in Port-au-Prince and Cap-Haitien associated to realistic possible major earthquakes. Our findings show that almost 50 % of the building stock of both cities would result uninhabitable due to structural damage. Around 80 % of the buildings in both cities have reinforced concrete structure with concrete block infill; however, the presence of masonry buildings becomes significant (between 25 and 45 % of the reinforced concrete buildings) in rural areas and informal settlements on the outskirts, where the estimated damage is higher. The influence of the soil effect on the damage spatial distribution is evident in both cities. We have found that the percentage of uninhabitable buildings in soft soil areas may be double the percentage obtained in nearby districts located in hard soil. These results reveal that a new seismic catastrophe of similar or even greater consequences than the 2010 Haiti earthquake might happen if the earthquake resilience is not improved in the country. Nowadays, the design of prevention actions and mitigation policies is the best instrument the society has to face seismic risk. In this sense, the results of this research might contribute to define measures oriented to earthquake risk reduction in Haiti, which should be a real priority for national and international institutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subject of Construction of Structures I studies, from a constructive point of view and taking into account current legislation, reinforced concrete structures used in buildings, through the acquisition of knowledge and construction criteria required in the profession of a Technical Architect. The contents acquired in this course are essential for further professional development of technicians and are closely related to many of the subjects taught in the same or other courses of the Degree in Technical Architecture at the University of Alicante. The aim of this paper is to present, analyze and discuss the development of a new methodology proposed in the mentioned subject, as it supposed an important change in the traditional way of teaching Construction and Structures I. In order to incorporate new teaching tools in 2013-2014, the course has been implemented by using a Moodle software tool to promote blended learning with online exercises. Our Moodle community allows collaborative work within an open-source platform where teachers and students share a new and personalized learning environment. Students are easily used to the interface and the platform, value the constant connection with teachers or other fellows and completely agree with the possibility of making questions or share documents 24 hours a day. The proposed methodology consists of lectures and practical classes. In the lectures, the basics of each topic are discussed; class attendance, daily study and conducting scheduled exercises are indispensable. Practical classes allow to consolidate the knowledge gained in theory classes by solving professional exercises and actual construction problems related to structures, that shall be compulsorily delivered online. So, after the correction of the teacher and the subsequent feedback of students, practical exercises ensure lifelong learning of the student, who can download any kind of material at any time (constructive details, practical exercises and even corrected exams). Regarding the general evaluation system, goals achievement is assessed on an ongoing basis (65% of the final mark) along the course through written and graphic evidences in person and online, as well as a individual development of a workbook. In all cases, the acquisition of skills, the ability to synthesize, the capacity of logical and critical thinking are assessed. The other 35 % of the mark is evaluated by a complementary graphic exam. Participation in the computing platform is essential and the student is required to do and present, at least 90% of the practices proposed. Those who do not comply with the practices in each specific date could not be assessed continuously and may only choose the final exam. In conclusion, the subject of Construction of Structures I is essential in the development of the regulated profession of Technical Architect as they are considered, among other professional profiles, as specialists in construction of building structures. The use of a new communication platform and online teaching allows the acquisition of knowledge and constructive approaches in a continuous way, with a more direct and personal monitoring by the teacher that has been highly appreciated by almost 100% of the students. Ultimately, it is important to say that the use of Moodle in this subject is a very interesting tool, which was really well welcome by students in one of the densest and important subjects of the Degree of Technical Architecture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En el conjunto de materiales de construcción habituales en la edificación y las obras de ingeniería, el hormigón destaca entre otras razones por su excelente comportamiento frente a las altas temperaturas y la exposición al fuego. El presente estudio se centra en la adherencia residual entre el hormigón y las barras de acero corrugado soldable tras exponer probetas a altas temperaturas y enfriarlas hasta temperatura ambiente por convección natural. El estudio incluye hormigones de resistencia convencional, hormigones de alta resistencia y hormigones reforzados con fibras de polipropileno y fibras de acero. La adherencia hormigón-acero se ha medido mediante el conocido ensayo de pull-out. La campaña experimental también ha incluido la resistencia a compresión y la resistencia a tracción indirecta. Parte de las probetas se han ensayado a 28 días de edad a temperatura ambiente. A 60 días de edad se han repetido los ensayos a temperatura ambiente y se han realizado esos mismos ensayos en probetas calentadas en un horno industrial hasta tres rangos de temperatura: 450°C, 650°C y 825°C. Previo al proceso de calentamiento han sido sometidas durante 3 horas a un escalón de secado a 120°C. Mediante la metodología propuesta ha sido posible caracterizar la evolución de la pérdida de adherencia residual entre el acero y el hormigón conforme se exponen los especímenes a temperaturas más elevadas. La adición de fibras no tiene una influencia clara en la adherencia a temperatura ambiente. Sin embargo, sí se ha conseguido determinar una mejora sustancial de la adherencia residual en los hormigones, reforzados con fibras de acero sometidos a altas temperaturas.