12 resultados para Recycled aggregates of concrete
em Universidad de Alicante
Resumo:
It has been analyzed samples of portland cement (PC) with and without admixtures, samples of calcium aluminate cement (CAC) with different content of Al2O3 and specimens of concrete made with PC and CAC using High Resolution Gamma Spectrometry. The activity concentration index (I) is much less than 0.5 mSv y-1 for all the concrete specimens according to the Radiation protection document 112 of the European Commission. The PC without admixtures (CEM I 52,5 R) and the PC with addition of limestone (CEM II/BL 32,5 N) also have an I value much lower than 0.5 and the PC with the addition of fly ash and blast furnace slag (CEM IV/B (V) 32,5 N and III/A 42.5 N/SR) have an I value close to 0.6. The I value of the CAC used in the manufacture of structural precast concrete is of the order of 1 mSv y-1. Some of the CAC used in refractory concrete reaches a value close to 2 mSv y-1.
Resumo:
Conformational changes of a humic acid (HA) and a fulvic acid (FA) induced by iron complexation were followed by high-performance size exclusion chromatography (HPSEC) with both UV–vis and refractive index (RI) detectors. Molecular size distribution was reduced for HA and increased for FA with progressive iron complexation. Since interactions of Fe with humic components are electrostatic, it is likely that the triple-charged Fe ions formed stronger complexes with the more acidic hydrophilic and hydrated FA than with the less acidic and more hydrophobic HA. The large content of ionized carboxyl groups in FA, thus favored the formation of intra- or intermolecular bridges between the negatively charged fulvic acid molecules, and led to more compact and larger size network than for HA. Conversely, iron complexation with HA disrupted the humic conformational arrangements stabilized by only weak hydrophobic bonds into smaller-size aggregates of greater conformational stability due to formation of strong metal complexes. These results confirmed that humic molecules in solution were organized in supramolecular associations of relatively small molecules loosely bound together by dispersive interactions and hydrogen bonds, and they specifically responded to chemical changes brought about by metal additions. The present study revealed the molecular changes occurring in superstructures of natural organic matter when in metal complexes and contributed to understand and predict the environmental behavior in waters and soil of metal complexes with natural organic matter.
Resumo:
The moisture content and its spatial distribution has a great influence on the durability properties of concrete structures. Several non-destructive techniques have been used for the determination of the total water content, but moisture distribution is difficult to determine. In this paper impedance spectroscopy is used to study the water distribution in concrete samples with controlled and homogeneously distributed moisture contents. The technique is suitable for the determination of water distribution inside the sample, using the appropriate equivalent circuits. It is shown that using the selected drying procedures there is no change in the solid phase of the samples, although the technique can only be used for the qualitative study of variations in the solid phase when samples are too thick. The results of this work show that for a wide range of concrete percentages of saturation, from full to 18 % saturation, practically all the pores keep at least a thin layer of electrolyte covering their walls, since the capacitance measurement results are practically independent of the saturation degree.
Resumo:
La détermination directe des caractéristiques de cisaillement des bétons par des essais universels est un problème qui reste encore une préoccupation majeure des chercheurs. La plupart des études disponibles consistent à appliquer un couple de torsion à un cylindre creux ayant un rapport épaisseur/rayon le plus faible possible. Ceci pour pouvoir élaborer un critère lié au comportement du matériau et non de la structure (Fourd et al. 1982). Cependant, ces essais peuvent présenter des dispersions liées aux problèmes de fragilité à la rupture ou de non homogénéité du matériau au sein de la paroi (Gotuwka et al. 1999). Pour cela, un dispositif expérimental original a été utilisé et qui consiste en la création de deux zones de contrainte nulle par l’emplacement de corps déformables au moment du coulage de l’éprouvette. De nouvelles conditions aux frontières sont créées permettant de transformer la sollicitation de compression en cisaillement plan sur une zone bien déterminée. L’utilisation de cette technique permet la détermination de l’influence de l’inclinaison du plan de rupture sur le comportement du béton en cisaillement. Le dispositif permet d’assurer la perpendicularité NOvEMBRE 2012 5 des génératrices du cylindre ainsi que la répartition et l’homogénéité des contraintes.
Resumo:
This paper describes the so-called Kiss Bridge. This structure resembles a kiss, a subtle touch of structures. The beams have been structurally designed to adapt the Japanese art of paper folding called "origami." The material used for constructing the floating beams is white reinforced concrete in the form of folded shells. The two geometrically different parts have distinct structural behaviors. The length of the main pathway of both structures is over 60 m. The pedestrian bridge crosses an artificial rainwater channel with a skew of 45° with respect to the referred channel. The joint between the cantilever structure and the Y-shaped one is located over the middle of the channel. Each stretch has different transversal sections. The pedestrian bridge is made with prestressed self-compacting reinforced concrete of 60 MPa. The foundation is shallow, comprising footings and footing beams made of 25 MPa conventional concrete. The cantilever structure with its foundations is designed as a semi-integral bridge whereas the Y-shaped one is an integral structure. The dynamic behavior of the structure was carefully studied to ensure that the dynamic loads generated by pedestrians do not cause excessive vibrations, especially to the cantilever structure, which could present dynamic interactions with the pedestrians walking. The bridge was recognized, in the 2014 edition of the fib Awards for Outstanding Concrete Structures, for having made a valuable contribution to the image and promotion of concrete structures.
Resumo:
Measurement of concrete strain through non-invasive methods is of great importance in civil engineering and structural analysis. Traditional methods use laser speckle and high quality cameras that may result too expensive for many applications. Here we present a method for measuring concrete deformations with a standard reflex camera and image processing for tracking objects in the concretes surface. Two different approaches are presented here. In the first one, on-purpose objects are drawn on the surface, while on the second one we track small defects on the surface due to air bubbles in the hardening process. The method has been tested on a concrete sample under several loading/unloading cycles. A stop-motion sequence of the process has been captured and analyzed. Results have been successfully compared with the values given by a strain gauge. Accuracy of our methods in tracking objects is below 8 μm, in the order of more expensive commercial devices.
Resumo:
Mercury intrusion porosimetry (MIP) has been widely used to evaluate the quality of concrete through the pore size distribution parameters. Two of these parameters are the critical pore diameter (Dcrit) and the percentage of the most interconnected net of pores compared to the total volume of pores. Some researchers consider Dcrit as the diameter obtained from the inflexion point of the cumulative mercury intrusion curve while others consider Dcrit as the diameter obtained from the point of abrupt variation in the same curve. This study aims to analyze two groups of concretes of varying w/c ratios, one cast with pozzolanic cement and another with high initial strength cement, in order to determine which of these diameters feature a better correlation with the quality parameters of the concretes. The concrete quality parameters used for the evaluations were (1) the w/c ratios and (2) chloride diffusion coefficients measured at approximately 90 days. MIP cumulative distributions of the same concretes were also measured at about 90 days, and Dcrit values were determined (1) from the point of abrupt variation and alternatively, (2) from the inflexion point of each of these plots. It was found that Dcrit values measured from the point of abrupt variation were useful indicators of the quality of the concrete, but the Dcrit values based on the inflexion points were not. Hence, it is recommended that Dcrit and the percentage of the most interconnected volume of pores should be obtained considering the point of abrupt variation of the cumulative curve of pore size distribution.
Resumo:
La fluencia de las rocas tiene gran importancia en la evaluación del comportamiento a largo plazo de elementos construidos con estos materiales. En este trabajo, se ha caracterizado física y mecánicamente una calcarenita porosa bien conocida localmente como Piedra de San Julián. Se han realizado ensayos de compresión uniaxial de 96 h. a carga constante. Se ha utilizado un modelo de fluencia bien conocido, el Código-modelo CEB-FIP 2010, usado para modelizar otro material pétreo (hormigón). Además, se ha propuesto un modelo reológico. El objetivo principal de este trabajo es investigar la posibilidad de aprovechar la gran experiencia acumulada en el estudio del hormigón, con el fin de obtener un enfoque para el comportamiento de la roca, para tiempos de prueba muy largos difíciles de implementar en laboratorio. Se propone una función de fluencia adaptada a la roca estudiada dependiente sólo de sus características elásticas y mecánicas.
Resumo:
El presente artículo se centra en la valorización de las cenizas de lodo de depuradora adicionadas en bloques de hormigón prefabricados, por tanto, en una matriz a base de cemento Portland con características particulares (consistencia seca). Se realiza una experiencia piloto mediante la fabricación de bloques en una planta industrial local, utilizando mezclas con porcentajes de sustitución de árido fino del 5, 10 y 15% por cenizas de lodo de depuradora, cuyos resultados se compararán con bloques de referencia (sin adición). Los ensayos aplicados son los preceptivos para su comercialización según normativa europea (marcado CE), lo que permitirá igualmente comprobar las características físicas y mecánicas de los hormigones. Los resultados obtenidos son prometedores: la utilización de este residuo permitiría su comercialización, mejora características de los bloques como la resistencia a compresión, y permitiría reducir un gran volumen de material utilizado habitualmente como materia prima y consumir un residuo destinado a vertedero.
Resumo:
The paper presents an analytical review of the literature, which reflects the results of national and foreign scientific researches aimed to studying the features of the composition and dosage of components of self compacting concrete as one of the most promising aggregate for modern composite structures. In addition, the results of numerical and experimental researches of stress-strain state of composite structures (concrete-filled tubes) under the influence of various power factors, have been considered. The description and features of existing analytical methods for the determination of the bearing capacity of the considered structures under compression and bendings, have been given. The analysis of deformation model of confined concrete in a composition of the composite structure, as well as non-linear models of steel works with their distinctive features, has been carried out. The main approaches to the finite element modeling of composite structures have been determined.
Resumo:
Concern for the environment has lately heightened awareness about the need for recycling in the construction industry. However, some standards, such as the Spanish standard, only accept the recycling of aggregates derived from concrete, which limits the extensive use of construction and demolition waste, which are produced in much bigger volumes. The aim of this work was to explore the possibility of using recycled mixed aggregates (RMA) in the preparation of precast non-structural concretes. To that end different percentages of natural aggregate were replaced by RMA in non-structural elements (25, 50, 75 and 100%). Contents of cement, water, and the dosages commonly used by companies were unchanged by the introduction of RMA. The characterization of the prepared elements has been done using the specific tests for each type of non-structural element (terrazzo for indoor use, hollow tiles, kerbstones and paving blocks): compression and flexural strength, water absorption, dimensional tolerances, abrasion and slipping resistance. The paving blocks, kerbstones, and hollow tiles prepared were tested for 360 days. The stability of the tested properties confirmed the possibility of using these wastes on an industrial scale satisfying the standard requirements. However, the surface of terrazzo with RMA is not as good as that prepared with natural aggregate.
Resumo:
The use of sustainable materials is becoming a common practice for noise abatement in building and civil engineering industries. In this context, many applications have been found for porous concrete made from lightweight aggregates. This work investigates the acoustic properties of porous concrete made from arlite and vermiculite lightweight aggregates. These natural resources can still be regarded as sustainable since they can be recycled and do not generate environmentally hazardous waste. The experimental basis used consists of different type specimens whose acoustic performance is assessed in an impedance tube. Additionally, a simple theoretical model for granular porous media, based on parameters measurable with basic experimental procedures, is adopted to predict the acoustic properties of the prepared mixes. The theoretical predictions compare well with the absorption measurements. Preliminary results show the good absorption capability of these materials, making them a promising alternative to traditional porous concrete solutions.