5 resultados para Receiver Operator Characteristic (ROC) curve
em Universidad de Alicante
Resumo:
Purpose. To analyze the diagnostic validity of accommodative and binocular tests in a sample of patients with a large near exophoria with moderate to severe symptoms. Methods. Two groups of patients between 19 and 35 years were recruited from a university clinic: 33 subjects with large exophoria at near vision and moderate or high visual discomfort and 33 patients with normal heterophoria and low visual discomfort. Visual discomfort was defined using the Conlon survey. A refractive exam and an exhaustive evaluation of accommodation and vergence were assessed. Diagnostic validity by means of receiver operator characteristic (ROC) curves, sensitivity (S), specificity (Sp), and positive and negative likelihood ratios (LR+, LR−) were assessed. This analysis was also carried out considering multiple tests as serial testing strategy. Results. ROC analysis showed the best diagnostic accuracy for receded near point of convergence (NPC) recovery (area = 0.929) and binocular accommodative facility (BAF) (area = 0.886). Using the cut-offs obtained with ROC analysis, the best diagnostic validity was obtained for the combination of NPC recovery and BAF (S = 0.77, Sp = 1, LR+ = value tending to infinity, LR− = 0.23) and the combination of NPC break and recovery with BAF (S = 0.73, Sp = 1, LR+ = tending to infinity, LR− = 0.27). Conclusions. NPC and BAF tests were the tests with the best diagnostic accuracy for subjects with large near exophoria and moderate to severe symptoms.
Resumo:
Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Study Design and Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Testeretest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen’s kappa (k). Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good testeretest repeatability both for the scores obtained [ICC 5 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (k 5 0.612; 95% CI: 0.384, 0.839). Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.
Resumo:
Background: The Strengths and Difficulties Questionnaire (SDQ) is a tool to measure the risk for mental disorders in children. The aim of this study is to describe the diagnostic efficiency and internal structure of the SDQ in the sample of children studied in the Spanish National Health Survey 2006. Methods: A representative sample of 6,773 children aged 4 to 15 years was studied. The data were obtained using the Minors Questionnaire in the Spanish National Health Survey 2006. The ROC curve was constructed and calculations made of the area under the curve, sensitivity, specificity and the Youden J indices. The factorial structure was studied using models of exploratory factorial analysis (EFA) and confirmatory factorial analysis (CFA). Results: The prevalence of behavioural disorders varied between 0.47% and 1.18% according to the requisites of the diagnostic definition. The area under the ROC curve varied from 0.84 to 0.91 according to the diagnosis. Factor models were cross-validated by means of two different random subsamples for EFA and CFA. An EFA suggested a three correlated factor model. CFA confirmed this model. A five-factor model according to EFA and the theoretical five-factor model described in the bibliography were also confirmed. The reliabilities of the factors of the different models were acceptable (>0.70, except for one factor with reliability 0.62). Conclusions: The diagnostic behaviour of the SDQ in the Spanish population is within the working limits described in other countries. According to the results obtained in this study, the diagnostic efficiency of the questionnaire is adequate to identify probable cases of psychiatric disorders in low prevalence populations. Regarding the factorial structure we found that both the five and the three factor models fit the data with acceptable goodness of fit indexes, the latter including an externalization and internalization dimension and perhaps a meaningful positive social dimension. Accordingly, we recommend studying whether these differences depend on sociocultural factors or are, in fact, due to methodological questions.
Resumo:
Purpose. To assess in a sample of normal, keratoconic, and keratoconus (KC) suspect eyes the performance of a set of new topographic indices computed directly from the digitized images of the Placido rings. Methods. This comparative study was composed of a total of 124 eyes of 106 patients from the ophthalmic clinics Vissum Alicante and Vissum Almería (Spain) divided into three groups: control group (50 eyes), KC group (50 eyes), and KC suspect group (24 eyes). In all cases, a comprehensive examination was performed, including the corneal topography with a Placidobased CSO topography system. Clinical outcomes were compared among groups, along with the discriminating performance of the proposed irregularity indices. Results. Significant differences at level 0.05 were found on the values of the indices among groups by means of Mann-Whitney-Wilcoxon nonparametric test and Fisher exact test. Additional statistical methods, such as receiver operating characteristic analysis and K-fold cross validation, confirmed the capability of the indices to discriminate between the three groups. Conclusions. Direct analysis of the digitized images of the Placido mires projected on the cornea is a valid and effective tool for detection of corneal irregularities. Although based only on the data from the anterior surface of the cornea, the new indices performed well even when applied to the KC suspect eyes. They have the advantage of simplicity of calculation combined with high sensitivity in corneal irregularity detection and thus can be used as supplementary criteria for diagnosing and grading KC that can be added to the current keratometric classifications.
Resumo:
Introduction. To date, no rating scales for detecting apathy in Parkinson’s disease (PD) patients have been validated in Spanish. For this reason, the aim of this study was to validate a Spanish version of Lille apathy rating scale (LARS) in a cohort of PD patients from Spain. Participants and Methods. 130 PD patients and 70 healthy controls were recruited to participate in the study. Apathy was measured using the Spanish version of LARS and the neuropsychiatric inventory (NPI). Reliability (internal consistency, test-retest, and interrater reliability) and validity (construct, content, and criterion validity) were measured. Results. Interrater reliability was 0.93. Cronbach’s α for LARS was 0.81. The test-retest correlation coefficient was 0.97. The correlation between LARS and NPI scores was 0.61. The optimal cutoff point under the ROC curve was , whereas the value derived from healthy controls was . The prevalence of apathy in our population tested by LARS was 42%. Conclusions. The Spanish version of LARS is a reliable and useful tool for diagnosing apathy in PD patients. Total LARS score is influenced by the presence of depression and cognitive impairment. However, both disorders are independent identities with respect to apathy. The satisfactory reliability and validity of the scale make it an appropriate instrument for screening and diagnosing apathy in clinical practice or for research purposes.