Resumo:
Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.
Resumo:
Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Resumo:
Background To evaluate the 3-year clinical outcomes after toric implantable collamer lens (ICL) implantation for the management of moderate to high myopic astigmatism. Methods Thirty-four eyes of 20 patients who underwent toric ICL implantation were reviewed. All eyes completed 3-year follow-up. Uncorrected (UDVA) and corrected (CDVA) distance LogMAR visual acuities, refraction, endothelial cell density (ECD), and surgical complications were evaluated. Vectorial analysis of astigmatic correction was also done. Results A significant improvement in UDVA, CDVA, manifest spherical and cylindrical refraction was observed at 1 week and remained stable after 3 years. Twenty-six eyes (76.5 %) gained lines of CDVA, and two eyes (5.9 %) showed a loss of 1 line of CDVA. The spherical equivalent (SE) was within ±0.50 D of emmetropia in 18 eyes (52.9 %) and within ±1.00 D in 28 eyes (82.4 %). Differences between target-induced astigmatism (TIA) and surgically-induced astigmatism (SIA) were statistically significant (p < 0.01), and a trend to undercorrection of the refractive astigmatism was present after 3 years. The magnitude of flattening effect (FE) was found to be significantly lower than the magnitude of TIA (p < 0.01). The magnitude of the torque vector was always positive, with a value below 0.50 D in all cases. No vision-threatening complications were observed during the follow-up. Conclusion Toric ICL implantation is an effective and safe surgical option that provides a relatively predictable and stable refractive correction of myopic astigmatism. Further improvements are needed to minimize the degree of undercorrection.
Resumo:
Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.
Resumo:
Background To analyze and compare the relationship between anterior and posterior corneal shape evaluated by a tomographic system combining the Scheimpflug photography and Placido-disc in keratoconus and normal healthy eyes, as well as to evaluate its potential diagnostic value. Methods Comparative case series including a sample of 161 eyes of 161 subjects with ages ranging from 7 to 66 years and divided into two groups: normal group including 100 healthy eyes of 100 subjects, and keratoconus group including 61 keratoconus eyes of 61 patients. All eyes received a comprehensive ophthalmologic examination including an anterior segment analysis with the Sirius system (CSO). Antero-posterior ratios for corneal curvature (k ratio) and shape factor (p ratio) were calculated. Logistic regression analysis was used to evaluate if some antero–posterior ratios combined with other clinical parameters were predictors of the presence of keratoconus. Results No statistically significant differences between groups were found in the antero–posterior k ratios for 3-, 5- and 7-mm diameter corneal areas (p ≥ 0.09). The antero–posterior p ratio for 4.5- and 8-mm diameter corneal areas was significantly higher in the normal group than in the keratoconus group (p < 0.01). The k ratio for 3, 5, and 7 mm was significantly higher in the keratoconus grade IV subgroup than in the normal group (p < 0.01). Furthermore, significant differences were found in the p ratio between the normal group and the keratoconus grade II subgroup (p ≤ 0.01). Finally, the logistic regression analysis identified as significant independent predictors of the presence of keratoconus (p < 0.01) the 8-mm anterior shape factor, the anterior chamber depth, and the minimal corneal thickness. Conclusions The antero-posterior k and p ratios are parameters with poor prediction ability for keratoconus, in spite of the trend to the presence of more prolate posterior corneal surfaces compared to the anterior in keratoconus eyes.
Resumo:
Background To evaluate and report the visual, refractive, and aberrometric outcomes of LASIK for the correction of low to moderate hyperopia in a pilot group using a commercially available solid-state laser. Methods Prospective pilot study including 11 consecutive eyes with low to moderate hyperopia of six patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd., currently CV Laser). Visual, refractive, and aberrometric changes were evaluated. Potential complications were evaluated as well. Mean follow-up time was 6.6 months (range, 3 to 11 months). Results A significant improvement in LogMAR uncorrected distance visual acuity (UDVA) was observed postoperatively (p = 0.01). No significant change was detected in LogMAR corrected distance visual acuity (CDVA) (p = 0.21). Postoperative LogMAR UDVA was 0.1 (about 20/25) or better in ten eyes (90.9 %). Mean overall efficacy and safety indices were 1.03 and 1.12. Postoperatively, no losses of lines of CDVA were observed. Postoperative spherical equivalent was within ±1.00 D in ten eyes (90.9 %). With regard to aberrations, no statistically significant changes were found in higher order and primary coma RMS postoperatively (p ≥ 0.21), and only minimal but statistically significant negativization of primary spherical aberration (p = 0.02) was observed. No severe complications were observed. Conclusion LASIK surgery using the solid-state laser technology seems to be a useful procedure for the correction of low to moderate hyperopia, with minimal induction of higher order aberrations.
Resumo:
Background: Retinal ganglion cell death underlies the pathophysiology of neurodegenerative disorders such as glaucoma or optic nerve trauma. To assess the potential influence of photoreceptor degeneration on retinal ganglion cell survival, and to evaluate functionality, we took advantage of the optic nerve section mouse model. Methods: Surviving retinal ganglion cells were double-stained by exposing both superior colliculi to fluorogold, and by applying dextran-tetramethylrhodamine to the injured optic nerve stump. To assess retinal function in wild-type animals, electroretinograms were recorded on the injured eyes and compared with the contralateral. Similar labelling experiments were carried out on retinal degeneration 1 mice. Surviving retinal ganglion cells were counted 21 days after axotomy and compared with wild-type mice. No functional experiments were performed on retinal degeneration 1 animals because they do not develop normal electroretinographical responses. Results: A significant decrease in retinal ganglion cell density was observed 6 days after axotomy in the wild type. Functional studies revealed that, in scotopic conditions, axotomy induced a significant amplitude decrease in the positive scotopic threshold response component of the electroretinogram. Such decrease paralleled cell loss, suggesting it may be an appropriate technique to evaluate functionality. When comparing retinal ganglion cell densities in wild-type and retinal degeneration 1 mice, a significant greater survival was observed on the latter. Conclusions: After optic nerve section, electroretinographical recordings exhibited a progressive decrease in the amplitude of the positive scotopic threshold response wave, reflecting ganglion cell loss. Interestingly, rod degeneration seemed, at least initially, to protect from axotomy-driven damage.
Resumo:
Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.
Resumo:
Biomechanics is often defined as ‘mechanics applied to biology’. Due to the variety and complexity of the behaviour of biological structures and materials, biomechanics is better defined as the development, extension and application of mechanics for a better understanding of physiology and physiopathology and consequently for a better diagnosis and treatment of disease and injury. Different methods for the characterisation of corneal biomechanics are reviewed in detail, including those that are currently commercially available (Ocular Response Analyzer and CorVis ST). The clinical applicability of the parameters provided by these devices are discussed, especially in the fields of glaucoma, detection of ectatic disorders and orthokeratology. Likewise, other methods are also reviewed, such as Brillouin microscopy or dynamic optical coherence tomography and others with potential application to clinical practice but not validated for in vivo measurements, such as ultrasonic elastography. Advantages and disadvantages of all these techniques are described. Finally, the concept of biomechanical modelling is revised as well as the requirements for developing biomechanical models, with special emphasis on finite element modelling.
Resumo:
Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.