4 resultados para Prism Yearbooks

em Universidad de Alicante


Relevância:

10.00% 10.00%

Publicador:

Resumo:

High resolution seismic profiles of the Alicante continental shelf have been studied identifying a seismic prism which top at about -20 m below today sea-level. The prism is covered by recent sediments and can be interpreted as formed during a short interval of stand-by in the general transgression after the last glacial maximum. The -20 m level have been compared with the holocene Mediterranean sea-level-curve to propose an age of about 8 ka BP coinciding with the «8.2 ka cooling event» that was an abrupt, widespread climate instability. The prism top is deeper in the northern seismic profiles thus indicating a more subsidence that the southern coastal shelf where an erosion surface with rocky shoals configure the sea bottom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Con el objetivo de ampliar los conocimientos en relación a los cambios recientes del nivel en la plataforma continental de Alicante se ha procedido al estudio de diferentes perfiles sísmicos de alta resolución. En el presente trabajo se ha identificado un prisma sedimentario cuyo techo se ubica alrededor de los 60 metros por debajo del nivel del mar actual. Comparando los resultados con la curva de variaciones del nivel del mar de los últimos 20 milenios, se puede confirmar que éste se formó durante un periodo en que el nivel del mar permaneció relativamente constante o disminuyó levemente entre el final del Bølling Warming y tras el evento frío Younger Dryas. Un total de tres unidades sísmicas (1, 2 y 3 de base a techo) se pueden diferenciar en el prisma. La subunidad 1, depositada entre el final del Bølling Warming y antes del Younger Dryas, indicando una mayor ralentización de la tasa de ascenso del nivel del mar. La subunidad 2, formada durante el evento frío Younger Dryas, reflejando un episodio de detención del nivel del mar alrededor de los 60 metros, seguido de una caída relativa mismo. La subunidad 3, formada tras este periodo frío y que se caracteriza por un incremento de la tasa de ascenso del nivel del mar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate two cases of intermittent exotropia (IX(T)) treated by vision therapy the efficacy of the treatment by complementing the clinical examination with a 3-D video-oculography to register and to evidence the potential applicability of this technology for such purpose. Methods: We report the binocular alignment changes occurring after vision therapy in a woman of 36 years with an IX(T) of 25 prism diopters (Δ) at far and 18 Δ at near and a child of 10 years with 8 Δ of IX(T) in primary position associated to 6 Δ of left eye hypotropia. Both patients presented good visual acuity with correction in both eyes. Instability of ocular deviation was evident by VOG analysis, revealing also the presence of vertical and torsional components. Binocular vision therapy was prescribed and performed including different types of vergence, accommodation, and consciousness of diplopia training. Results: After therapy, excellent ranges of fusional vergence and a “to-the-nose” near point of convergence were obtained. The 3-D VOG examination (Sensoro Motoric Instruments, Teltow, Germany) confirmed the compensation of the deviation with a high level of stability of binocular alignment. Significant improvement could be observed after therapy in the vertical and torsional components that were found to become more stable. Patients were very satisfied with the outcome obtained by vision therapy. Conclusion: 3D-VOG is a useful technique for providing an objective register of the compensation of the ocular deviation and the stability of the binocular alignment achieved after vision therapy in cases of IX(T), providing a detailed analysis of vertical and torsional improvements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Evaluar la eficacia del tratamiento en 3 casos de exotropia intermitente (XT(i)) mediante ejercicios de terapia visual, completando la exploración clínica con Videooculografia-30 y evidenciar la potencial aplicabilidad de esta tecnología para dicho propósito. Métodos: Exponemos los cambios ocurridos tras ejercicios de terapia visual en una mujer de 36 años con XT(i) de -25 dioptrías prismáticas (dp) de lejos y 18 dp de cerca; Un niño de 10 años de edad con 8 dp de XT(i) en posición primaria, asociados a +6 dp de hipotropia izquierda; y un hombre de 63 años con XT(i) de 6 dp en posición primaria asociada a +7 dp de hipertropia derecha. Todos los pacientes presentaron buena agudeza visual corregida en ambos ojos. La inestabilidad de la desviación ocular se evidenció mediante análisis de VOG-30, revelando la presencia de components verticales y torsionales. Se realizaron ejercicios de terapia visual, incluyendo diferentes tipos de ejercicios de vergencias, acomodación y percepción de la diplopía. Resultados: Tras la terapia visual se obtuvieron excelentes rangos de vergencias fusionales y de punto próximo de convergencia («hasta la nariz»). El examen mediante VOG-3D (Sensoro Motoric lnstruments, Teltow, Germany) confirmó la compensación de la desviación con estabilidad del alineamiento ocular. Se observó una significativa mejora después de la terapia en los components verticals y torsionales, lo cuales se hicieron más estables. Los pacientes se mostraron muy satisfechos de los resultados obtenidos. Conclusión: La VOG-3D es una técnica útil para dotamos de un método objetivo de registro de la compensación y estabilidad de la desviación ocular después de realizar ejercicios de terapia visual en casos de XT(i), ofreciéndonos un detallado análisis de la mejoría de los components verticales y torsionales.