4 resultados para NaCl 7.5%

em Universidad de Alicante


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Glutamate synthase (GOGAT) is one of the two important enzymes involved in the ammonium assimilation pathway glutamine synthetase (GS)/GOGAT, which enables Hfx. mediterranei to thrive in media with low ammonium concentration or containing just nitrate as single nitrogen source. The gene coding for this enzyme, gltS, has been sequenced, analysed and compared with other GOGATs from different organisms from the three domains of life. According to its amino acid sequence, Hfx. mediterranei GOGAT displays high homology with those from other archaeal halophilic organisms and with the bacterial alpha-like subunit. Hfx. mediterranei GOGAT and GS expression was induced under conditions of ammonium restriction. The GOGAT protein was found to be a monomer with a molecular mass of 163.78 kDa, which is consistent with that estimated by gel filtration, 198 ± 30 kDa. The enzyme is highly ferredoxin dependent: activity was only observed with one of the two different 2Fe–2S ferredoxins chromatographically isolated from Hfx. mediterranei. The enzyme also displayed typical halophilic behaviour, being fully stable, and producing maximal activity, at salt concentrations from 3 to 4 M NaCl, pH 7.5 and a temperature of 50 °C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel and environment friendly analytical method is reported for total chromium determination and chromium speciation in water samples, whereby tungsten coil atomic emission spectrometry (WCAES) is combined with in situ ionic liquid formation dispersive liquid–liquid microextraction (in situ IL-DLLME). A two stage multivariate optimization approach has been developed employing a Plackett–Burman design for screening and selection of the significant factor involved in the in situ IL-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were complexant concentration: 0.5% (or 0.1%); complexant type: DDTC; IL anion: View the MathML sourcePF6−; [Hmim][Cl] IL amount: 60 mg; ionic strength: 0% NaCl; pH: 5 (or 2); centrifugation time: 10 min; and centrifugation speed: 1000 rpm. Under the optimized experimental conditions the method was evaluated and proper linearity was obtained with a correlation coefficient of 0.991 (5 calibration standards). Limits of detection and quantification for both chromium species were 3 and 10 µg L−1, respectively. This is a 233-fold improvement when compared with chromium determination by WCAES without using preconcentration. The repeatability of the proposed method was evaluated at two different spiking levels (10 and 50 µg L−1) obtaining coefficients of variation of 11.4% and 3.6% (n=3), respectively. A certified reference material (SRM-1643e NIST) was analyzed in order to determine the accuracy of the method for total chromium determination and 112.3% and 2.5 µg L−1 were the recovery (trueness) and standard deviation values, respectively. Tap, bottled mineral and natural mineral water samples were analyzed at 60 µg L−1 spiking level of total Cr content at two Cr(VI)/Cr(III) ratios, and relative recovery values ranged between 88% and 112% showing that the matrix has a negligible effect. To our knowledge, this is the first time that combines in situ IL-DLLME and WCAES.