6 resultados para Mean square analysis
em Universidad de Alicante
Resumo:
The Free Core Nutation (FCN) is a free mode of the Earth's rotation caused by the different material characteristics of the Earth's core and mantle. This causes the rotational axes of those layers to slightly diverge from each other, resulting in a wobble of the Earth's rotation axis comparable to nutations. In this paper we focus on estimating empirical FCN models using the observed nutations derived from the VLBI sessions between 1993 and 2013. Assuming a fixed value for the oscillation period, the time-variable amplitudes and phases are estimated by means of multiple sliding window analyses. The effects of using different a priori Earth Rotation Parameters (ERP) in the derivation of models are also addressed. The optimal choice of the fundamental parameters of the model, namely the window width and step-size of its shift, is searched by performing a thorough experimental analysis using real data. The former analyses lead to the derivation of a model with a temporal resolution higher than the one used in the models currently available, with a sliding window reduced to 400 days and a day-by-day shift. It is shown that this new model increases the accuracy of the modeling of the observed Earth's rotation. Besides, empirical models determined from USNO Finals as a priori ERP present a slightly lower Weighted Root Mean Square (WRMS) of residuals than IERS 08 C04 along the whole period of VLBI observations, according to our computations. The model is also validated through comparisons with other recognized models. The level of agreement among them is satisfactory. Let us remark that our estimates give rise to the lowest residuals and seem to reproduce the FCN signal in more detail.
Resumo:
La temperatura superficial del mar (SST) estimada a partir de los productos 11 μm diurnos y nocturnos y 4 μm nocturnos del sensor MODIS (Moderate Resolution Imaging Spectroradiometer) a bordo de la plataforma Aqua, han sido comparados con datos medidos in situ a tres profundidades diferentes (15, 50 y 100 cm) en una zona costera del Mediterráneo Occidental. Esta comparación ha permitido analizar la incertidumbre que existe en la estimación de este parámetro en aguas someras y próximas a la costa mediante imágenes de satélite de baja resolución espacial. Los resultados obtenidos demuestran que el producto diurno SST_11 μm, obtiene los estadísticos RMSE (error cuadrático medio) y r2 (coeficiente de correlación de Pearson) más ajustados con valores de 1°C y 0,96, respectivamente, para la profundidad 50 cm.
Resumo:
Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Reverse Geometry Hybrid Contact Lens Fitting in a Case of Donor-Host Misalignment after Keratoplasty
Resumo:
Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.
Resumo:
Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.
Resumo:
This paper deals with the estimation of a time-invariant channel spectrum from its own nonuniform samples, assuming there is a bound on the channel’s delay spread. Except for this last assumption, this is the basic estimation problem in systems providing channel spectral samples. However, as shown in the paper, the delay spread bound leads us to view the spectrum as a band-limited signal, rather than the Fourier transform of a tapped delay line (TDL). Using this alternative model, a linear estimator is presented that approximately minimizes the expected root-mean-square (RMS) error for a deterministic channel. Its main advantage over the TDL is that it takes into account the spectrum’s smoothness (time width), thus providing a performance improvement. The proposed estimator is compared numerically with the maximum likelihood (ML) estimator based on a TDL model in pilot-assisted channel estimation (PACE) for OFDM.