10 resultados para Mean Value Theorem

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

For non-negative random variables with finite means we introduce an analogous of the equilibrium residual-lifetime distribution based on the quantile function. This allows us to construct new distributions with support (0, 1), and to obtain a new quantile-based version of the probabilistic generalization of Taylor's theorem. Similarly, for pairs of stochastically ordered random variables we come to a new quantile-based form of the probabilistic mean value theorem. The latter involves a distribution that generalizes the Lorenz curve. We investigate the special case of proportional quantile functions and apply the given results to various models based on classes of distributions and measures of risk theory. Motivated by some stochastic comparisons, we also introduce the “expected reversed proportional shortfall order”, and a new characterization of random lifetimes involving the reversed hazard rate function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nowadays there is a big amount of biomedical literature which uses complex nouns and acronyms of biological entities thus complicating the task of retrieval specific information. The Genomics Track works for this goal and this paper describes the approach we used to take part of this track of TREC 2007. As this is the first time we participate in this track, we configurated a new system consisting of the following diferenciated parts: preprocessing, passage generation, document retrieval and passage (with the answer) extraction. We want to call special attention to the textual retrieval system used, which was developed by the University of Alicante. Adapting the resources for the propouse, our system has obtained precision results over the mean and median average of the 66 official runs for the Document, Aspect and Passage2 MAP; and in the case of Passage MAP we get nearly the median and mean value. We want to emphasize we have obtained these results without incorporating specific information about the domain of the track. For the future, we would like to further develop our system in this direction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using a scanning tunnelling microscope or mechanically controllable break junction it has been shown that it is possible to control the formation of a wire made of single gold atoms. In these experiments an interatomic distance between atoms in the chain of ∼3.6 Å was reported which is not consistent with recent theoretical calculations. Here, using precise calibration procedures for both techniques, we measure the length of the atomic chains. Based on the distance between the peaks observed in the chain length histogram we find the mean value of the interatomic distance before chain rupture to be 2.5±0.2 Å. This value agrees with the theoretical calculations for the bond length. The discrepancy with the previous experimental measurements was due to the presence of He gas, that was used to promote the thermal contact, and which affects the value of the work function that is commonly used to calibrate distances in scanning tunnelling microscopy and mechanically controllable break junctions at low temperatures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25–1 μm) at the mountain site, 55.0 ± 3.0 cm− 3, was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm− 3). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5–2 μm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1 cm− 3 at the urban site and 0.9 ± 0.1 cm− 3 at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of > 4.0 cm− 3, than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O3 levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3–17%) with respect to its mean value.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a comprehensive analysis of the whole sample of available XMM-Newton observations of high-mass X-ray binaries (HMXBs) until August 2013, focusing on the FeKα emission line. This line is key to better understanding the physical properties of the material surrounding the X-ray source within a few stellar radii (the circumstellar medium). We collected observations from 46 HMXBs and detected FeKα in 21 of them. We used the standard classification of HMXBs to divide the sample into different groups. We find that (1) different classes of HMXBs display different qualitative behaviours in the FeKα spectral region. This is visible especially in SGXBs (showing ubiquitous Fe fluorescence but not recombination Fe lines) and in γ Cass analogues (showing both fluorescent and recombination Fe lines). (2) FeKα is centred at a mean value of 6.42 keV. Considering the instrumental and fits uncertainties, this value is compatible with ionization states that are lower than Fe xviii. (3) The flux of the continuum is well correlated with the flux of the line, as expected. Eclipse observations show that the Fe fluorescence emission comes from an extended region surrounding the X-ray source. (4) We observe an inverse correlation between the X-ray luminosity and the equivalent width of FeKα (EW). This phenomenon is known as the X-ray Baldwin effect. (5) FeKα is narrow (σline< 0.15 keV), reflecting that the reprocessing material does not move at high speeds. We attempt to explain the broadness of the line in terms of three possible broadening phenomena: line blending, Compton scattering, and Doppler shifts (with velocities of the reprocessing material V ~ 1000 km s-1). (6) The equivalent hydrogen column (NH) directly correlates to the EW of FeKα, displaying clear similarities to numerical simulations. It highlights the strong link between the absorbing and the fluorescent matter. (7) The observed NH in supergiant X-ray binaries (SGXBs) is in general higher than in supergiant fast X-ray transients (SFXTs). We suggest two possible explanations: different orbital configurations or a different interaction compact object – wind. (8) Finally, we analysed the sources IGR J16320-4751 and 4U 1700-37 in more detail, covering several orbital phases. The observed variation in NH between phases is compatible with the absorption produced by the wind of their optical companions. The results clearly point to a very important contribution of the donor’s wind in the FeKα emission and the absorption when the donor is a supergiant massive star.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The complete characterization of rock masses implies the acquisition of information of both, the materials which compose the rock mass and the discontinuities which divide the outcrop. Recent advances in the use of remote sensing techniques – such as Light Detection and Ranging (LiDAR) – allow the accurate and dense acquisition of 3D information that can be used for the characterization of discontinuities. This work presents a novel methodology which allows the calculation of the normal spacing of persistent and non-persistent discontinuity sets using 3D point cloud datasets considering the three dimensional relationships between clusters. This approach requires that the 3D dataset has been previously classified. This implies that discontinuity sets are previously extracted, every single point is labeled with its corresponding discontinuity set and every exposed planar surface is analytically calculated. Then, for each discontinuity set the method calculates the normal spacing between an exposed plane and its nearest one considering 3D space relationship. This link between planes is obtained calculating for every point its nearest point member of the same discontinuity set, which provides its nearest plane. This allows calculating the normal spacing for every plane. Finally, the normal spacing is calculated as the mean value of all the normal spacings for each discontinuity set. The methodology is validated through three cases of study using synthetic data and 3D laser scanning datasets. The first case illustrates the fundamentals and the performance of the proposed methodology. The second and the third cases of study correspond to two rock slopes for which datasets were acquired using a 3D laser scanner. The second case study has shown that results obtained from the traditional and the proposed approaches are reasonably similar. Nevertheless, a discrepancy between both approaches has been found when the exposed planes members of a discontinuity set were hard to identify and when the planes pairing was difficult to establish during the fieldwork campaign. The third case study also has evidenced that when the number of identified exposed planes is high, the calculated normal spacing using the proposed approach is minor than those using the traditional approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Celiac disease (CD) has a negative impact on the health-related quality of life (HRQL) of affected patients. Although HRQL and its determinants have been examined in Spanish CD patients specifically recruited in hospital settings, these aspects of CD have not been assessed among the general Spanish population. Methods: An observational, transversal study of a non-randomized, representative sample of adult celiac patients throughout all of Spain's Autonomous Regions. Subjects were recruited through celiac patient associations. A Spanish version of the self-administered Celiac Disease-Quality of Life (CD-QOL) questionnaire was used. Determinant factors of HRQL were assessed with the aid of multivariate analysis to control for confounding factors. Results: We analyzed the responses provided by 1,230 patients, 1,092 (89.2%) of whom were women. The overall mean value for the CD-QOL index was 56.3 ± 18.27 points. The dimension that obtained the most points was dysphoria, with 81.3 ± 19.56 points, followed by limitations with 52.3 ± 23.43 points; health problems, with 51.6 ± 26.08 points, and inadequate treatment, with 36.1 ± 21.18 points. Patient age and sex, along with time to diagnosis, and length of time on a gluten-free diet were all independent determinant factors of certain dimensions of HRQL: women aged 31 to 40 expressed poorer HRQL while time to diagnosis and length of time on a gluten-free diet were determinant factors for better HRQL scores. Conclusions: The HRQL of adult Spanish celiac subjects is moderate, improving with the length of time patients remain on a gluten-free diet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An accurate and easy method for the extraction, cleanup, and HRGC-HRMS analysis of dioxin-like PCBs (DL-PCBs) in low-volume serum samples (1 mL) was developed. Serum samples were extracted several times using n-hexane and purified by acid washing. Recovery rates of labeled congeners ranged from 70 to 110 % and the limits of detection were below 1 pg/g on lipid basis. Although human studies are limited and contradictory, several studies have shown that DL-PCBs can have adverse effects on the male reproductive system. In this way, the present method was applied to 21 serum samples of male patients attending fertility clinics. The total levels obtained for the patients ranged from 6.90 to 84.1 pg WHO-TEQ/g lipid, with a mean value of 20.3 pg WHO-TEQ/g lipid. The predominant PCBs (the sum of PCB 118, 156, and 105) contributed 67 % to the mean concentration of total DL-PCBs in the samples analyzed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Materials with new visual appearances have emerged over the last few years. In the automotive industry in particular there is a growing interest in materials with new effect finishes, such as metallic, pearlescent, sparkle, and graininess effects. Typically, for solid colours the mean of three measurements with repetitions is sufficient to obtain a representative measurement for colour characterisation. However, gonio-apparent panels have non-homogeneous colours, and there are no studies that recommend the minimum number of repetitions for colour, sparkle, and graininess characterisation of this type of panel. We assume that colour panels incorporating special-effect pigments in their colour recipes will require a higher minimum number of measurements than solid colour panels. Therefore, the purpose of this study is to verify this assumption by using a multiangle BYK-mac spectrophotometer, given that it is currently the only commercial device that can measure colour, sparkle, and graininess values simultaneously. In addition, a possible methodology is given for establishing the minimum number of measurements when characterising gonio-apparent materials using a specific instrument, able to be implemented in future instruments when determining multiple appearance attributes (colour, gloss, sparkle, etc.) for many coloration technologies. Thus, we studied the minimum number of measurements needed to characterise the colour, sparkle, and graininess of three types of sample with solid, metallic, and pearlescent coatings respectively. Twenty measurements were made at twenty random positions (different target areas) of 90 samples. The minimum number of measurements for all these variables was determined on the basis of the point at which the cumulative mean value became constant. Thus, applying new statistical tools, it is clearly shown that metallic and pearlescent panels require more colour measurements than solid panels, in particular when geometries are being measured in a specular direction. As regards texture (sparkle and graininess), more measurements are needed for graininess than for sparkle, and more for metallic panels than for pearlescent panels.