3 resultados para MAGNETIC REVERSAL FREQUENCY

em Universidad de Alicante


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The magnetization reversal of two-dimensional arrays of parallel ferromagnetic Fe nanowires embedded in nanoporous alumina templates has been studied. By combining bulk magnetization measurements (superconducting quantum interference device magnetometry) with field-dependent magnetic force microscopy (MFM), we have been able to decompose the macroscopic hysteresis loop in terms of the irreversible magnetic responses of individual nanowires. The latter are found to behave as monodomain ferromagnetic needles, with hysteresis loops displaced (asymmetric) as a consequence of the strong dipolar interactions between them. The application of field-dependent MFM provides a microscopic method to obtain the hysteresis curve of the array, by simply registering the fraction of up and down magnetized wires as a function of applied field. The observed deviations from the rectangular shape of the macroscopic hysteresis loop of the array can be ascribed to the spatial variation of the dipolar field through the inhomogeneously filled membrane. The system studied proves to be an excellent example of the two-dimensional classical Preisach model, well known from the field of hysteresis modeling and micromagnetism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ferromagnetism is predicted in undoped diluted magnetic semiconductors illuminated by intense sub-band-gap laser radiation . The mechanism for photoinduced ferromagnetism is coherence between conduction and valence bands induced by the light which leads to an optical exchange interaction. The ferromagnetic critical temperature TC depends both on the properties of the material and on the frequency and intensity of the laser and could be above 1K.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider two intrinsic sources of noise in ultra-sensitive magnetic field sensors based on MgO magnetic tunnel junctions, coming both from 25 Mg nuclear spins (I = 5/2, 10% natural abundance) and S = 1 Mg-vacancies. While nuclear spins induce noise peaked in the MHz frequency range, the vacancies noise peaks in the GHz range. We find that the nuclear noise in submicron devices has a similar magnitude than the 1/f noise, while the vacancy-induced noise dominates in the GHz range. Interestingly, the noise spectrum under a finite magnetic field gradient may provide spatial information about the spins in the MgO layer.