2 resultados para Input saturation

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A conditioning procedure is proposed allowing to install into the concrete specimens any selected value of water saturation degree with homogeneous moisture distribution. This is achieved within the least time and the minimum alteration of the concrete specimens. The protocol has the following steps: obtaining basic drying data at 50 °C (water absorption capacity and drying curves); unidirectional drying of the specimens at 50 °C until reaching the target saturation degree values; redistribution phase in closed containers at 50 °C (with measurement of the quasi-equilibrium relative humidities); storage into controlled environment chambers until and during mass transport tests, if necessary. A water transport model is used to derive transport parameters of the tested materials from the drying data, i.e., relative permeabilities and apparent water diffusion coefficients. The model also allows calculating moisture profiles during isothermal drying and redistribution phases, thus allowing optimization of the redistribution times for obtaining homogeneous moisture distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extensive application of vinasse, a subproduct from sugar cane plantations for bioethanol production, is currently taking place as a source of nutrients that forms part of agricultural management in different agroclimatic regions. Liquid vinasse composition is characterised by high variability of organic compounds and major ions, acid pH (4.7), high TDS concentration (117,416–599,400 mg L− 1) and elevated EC (14,350–64,099 μS cm− 1). A large-scale sugar cane field application is taking place in Valle del Cauca (Colombia), where monitoring of soil, unsaturated zone and the aquifer underneath has been made since 2006 to evaluate possible impacts on three experimental plots. For this assessment, monitoring wells and piezometers were installed to determine groundwater flow and water samples were collected for chemical analysis. In the unsaturated zone, tensiometers were installed at different depths to determine flow patterns, while suction lysimeters were used for water sample chemical determinations. The findings show that in the sandy loam plot (Hacienda Real), the unsaturated zone is characterised by low water retention, showing a high transport capacity, while the other two plots of silty composition presented temporal saturation due to La Niña event (2010–2011). The strong La Niña effect on aquifer recharge which would dilute the infiltrated water during the monitoring period and, on the other hand dissolution of possible precipitated salts bringing them back into solution may occur. A slight increase in the concentration of major ions was observed in groundwater (~ 5% of TDS), which can be attributed to a combination of factors: vinasse dilution produced by water input and hydrochemical processes along with nutrient removal produced by sugar cane uptake. This fact may make the aquifer vulnerable to contamination.