4 resultados para Frequency range selection
em Universidad de Alicante
Resumo:
Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.
Resumo:
Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.
Resumo:
We consider two intrinsic sources of noise in ultra-sensitive magnetic field sensors based on MgO magnetic tunnel junctions, coming both from 25 Mg nuclear spins (I = 5/2, 10% natural abundance) and S = 1 Mg-vacancies. While nuclear spins induce noise peaked in the MHz frequency range, the vacancies noise peaks in the GHz range. We find that the nuclear noise in submicron devices has a similar magnitude than the 1/f noise, while the vacancy-induced noise dominates in the GHz range. Interestingly, the noise spectrum under a finite magnetic field gradient may provide spatial information about the spins in the MgO layer.
Resumo:
En este trabajo se describe el proceso llevado a cabo para analizar numéricamente mediante el método de los elementos finitos (MEF) el comportamiento vibratorio del conjunto móvil de un altavoz dinámico de bobina con doble suspensión inferior y en ausencia de la superior. El estudio se centra en el rango de baja frecuencia. El calibrado del modelo se realiza en base a medidas experimentales de la frecuencia de resonancia y desplazamiento del diafragma. Se hace énfasis en la importancia de los factores de participación asociados a la fuerza de excitación y en los cambios que se producen en estos al introducir fuerzas no equilibradas. Así mismo, el análisis proporciona datos para decidir sobre la distancia entre suspensiones, su número óptimo de pliegues y la ubicación de las trencillas, siendo estos parámetros de gran interés en el diseño de este tipo de altavoces.