4 resultados para Energy consumption -- Computer simulation

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Of all the costs associated with the operation and maintenance of wastewater treatment plants (WWTPs), those associated with energy use tend to be the most significant. From this point of view, it is hence logical that energy efficiency and saving strategies should be one of the current focuses of debate amongst those involved with the management of WWTPs. The present study's objective is to determine the correlation between size and energy consumption for a WWTP. To this end, 90 WWTPs currently in service were analysed and their energetic impact quantified in terms of kWh/m3 of water treated. The results obtained demonstrate that energy consumption ratio increases as the size of WWTPs decreases, either in terms of treatment volume or population equivalent served.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an alternative model to deal with the problem of optimal energy consumption minimization of non-isothermal systems with variable inlet and outlet temperatures. The model is based on an implicit temperature ordering and the “transshipment model” proposed by Papoulias and Grossmann (1983). It is supplemented with a set of logical relationships related to the relative position of the inlet temperatures of process streams and the dynamic temperature intervals. In the extreme situation of fixed inlet and outlet temperatures, the model reduces to the “transshipment model”. Several examples with fixed and variable temperatures are presented to illustrate the model's performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we study Forward Osmosis (FO) as an emerging desalination technology, and its capability to replace totally or partially Reverse Osmosis (RO) in order to reduce the great amount of energy required in the current desalination plants. For this purpose, we propose a superstructure that includes both membrane based desalination technologies, allowing the selection of only one of the technologies or a combination of both of them seeking for the optimal configuration of the network. The optimization problem is solved for a seawater desalination plant with a given fresh water production. The results obtained show that the optimal solution combines both desalination technologies to reduce not only the energy consumption but also the total cost of the desalination process in comparison with the same plant but operating only with RO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Information technologies (IT) currently represent 2% of CO2 emissions. In recent years, a wide variety of IT solutions have been proposed, focused on increasing the energy efficiency of network data centers. Monitoring is one of the fundamental pillars of these systems, providing the information necessary for adequate decision making. However, today’s monitoring systems (MSs) are partial, specific and highly coupled solutions. This study proposes a model for monitoring data centers that serves as a basis for energy saving systems, offered as a value-added service embedded in a device with low cost and power consumption. The proposal is general in nature, comprehensive, scalable and focused on heterogeneous environments, and it allows quick adaptation to the needs of changing and dynamic environments. Further, a prototype of the system has been implemented in several devices, which has allowed validation of the proposal in addition to identification of the minimum hardware profile required to support the model.