6 resultados para Educational Measurement - methods

em Universidad de Alicante


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: to identify aspects of improvement of the quality of the teaching-learning process through the analysis of tools that evaluated the acquisition of skills by undergraduate students of Nursing. Method: prospective longitudinal study conducted in a population of 60 second-year Nursing students based on registration data, from which quality indicators that evaluate the acquisition of skills were obtained, with descriptive and inferential analysis. Results: nine items were identified and nine learning activities included in the assessment tools that did not reach the established quality indicators (p<0.05). There are statistically significant differences depending on the hospital and clinical practices unit (p<0.05). Conclusion: the analysis of the evaluation tools used in the article "Nursing Care in Welfare Processes" of the analyzed university undergraduate course enabled the detection of the areas for improvement in the teaching-learning process. The challenge of education in nursing is to reach the best clinical research and educational results, in order to provide improvements to the quality of education and health care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate two cases of intermittent exotropia (IX(T)) treated by vision therapy the efficacy of the treatment by complementing the clinical examination with a 3-D video-oculography to register and to evidence the potential applicability of this technology for such purpose. Methods: We report the binocular alignment changes occurring after vision therapy in a woman of 36 years with an IX(T) of 25 prism diopters (Δ) at far and 18 Δ at near and a child of 10 years with 8 Δ of IX(T) in primary position associated to 6 Δ of left eye hypotropia. Both patients presented good visual acuity with correction in both eyes. Instability of ocular deviation was evident by VOG analysis, revealing also the presence of vertical and torsional components. Binocular vision therapy was prescribed and performed including different types of vergence, accommodation, and consciousness of diplopia training. Results: After therapy, excellent ranges of fusional vergence and a “to-the-nose” near point of convergence were obtained. The 3-D VOG examination (Sensoro Motoric Instruments, Teltow, Germany) confirmed the compensation of the deviation with a high level of stability of binocular alignment. Significant improvement could be observed after therapy in the vertical and torsional components that were found to become more stable. Patients were very satisfied with the outcome obtained by vision therapy. Conclusion: 3D-VOG is a useful technique for providing an objective register of the compensation of the ocular deviation and the stability of the binocular alignment achieved after vision therapy in cases of IX(T), providing a detailed analysis of vertical and torsional improvements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Software for video-based multi-point frequency measuring and mapping: http://hdl.handle.net/10045/53429