Resumo:
The impact noise reduction provided by floor coverings is usually obtained in laboratory, using the methodology described in the standard EN ISO 140-8, which requires the use of standard acoustic chambers. The construction of such chambers, following the requirements described in the EN ISO 140-1, implies a significant investment, and therefore only a limited number exists in each country. Alternatives to these standard methodologies, that allow a sufficiently accurate evaluation and require lower resources, have been interesting many researchers and manufacturers. In this paper, one such strategy is discussed, where a reduced sized slab is used to determine the noise reduction provided by floor coverings, following the procedure described in the ISO/CD 16251-1 technical document. Several resilient coverings, floating floors and floating slabs are tested and the results are compared with those obtained using the procedures described in the standards EN ISO 140-8 and EN ISO 717-2.
Resumo:
A conditioning procedure is proposed allowing to install into the concrete specimens any selected value of water saturation degree with homogeneous moisture distribution. This is achieved within the least time and the minimum alteration of the concrete specimens. The protocol has the following steps: obtaining basic drying data at 50 °C (water absorption capacity and drying curves); unidirectional drying of the specimens at 50 °C until reaching the target saturation degree values; redistribution phase in closed containers at 50 °C (with measurement of the quasi-equilibrium relative humidities); storage into controlled environment chambers until and during mass transport tests, if necessary. A water transport model is used to derive transport parameters of the tested materials from the drying data, i.e., relative permeabilities and apparent water diffusion coefficients. The model also allows calculating moisture profiles during isothermal drying and redistribution phases, thus allowing optimization of the redistribution times for obtaining homogeneous moisture distributions.
Resumo:
The effect of foundation embedment on settlement calculation is a widely researched topic in which there is no scientific consensus regarding the magnitude of settlement reduction. In this paper, a non-linear three dimensional Finite Element analysis has been performed with the aim of evaluating the aforementioned effect. For this purpose, 1800 models were run considering different variables, such as the depth and dimensions of the foundation and the Young’s modulus and Poisson’s ratio of the soil. The settlements from models with foundations at surface level and at depth were then compared and the relationship between them established. The statistical analysis of this data allowed two new expressions, with a mean maximum error of 1.80%, for the embedment influence factor of a foundation to be proposed and these to be compared with commonly used corrections. The proposed equations were validated by comparing the settlements calculated with the proposed influence factors and the true settlements measured in several real foundations. From the comprehensive study of all modelled cases, an improved approach, when compared to those proposed by other authors, for the calculation of the true elastic settlements of an embedded foundation is proposed.
Resumo:
Chlorides induce local corrosion in the steel reinforcements when reaching the bar surface. The measurement of the rate of ingress of these ions, is made by mathematically fitting the so called “error function equation” into the chloride concentration profile, obtaining so the diffusion coefficient and the chloride concentration at the concrete surface. However, the chloride profiles do not always follow Fick’s law by having the maximum concentration at the concrete surface, but often the profile shows a maximum concentration more in the interior, which indicates a different composition and performance of the most external concrete layer with respect to the internal zones. The paper presents a procedure prepared during the time of the RILEM TC 178-TMC: “Testing and modeling chloride penetration in concrete”, which suggests neglecting the external layer where the chloride concentration increases and using the maximum as an “apparent” surface concentration, called C max and to fit the error function equation into the decreasing concentration profile towards the interior. The prediction of evolution should be made also from the maximum.