156 resultados para Urbanismo y arquitectura modernos


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este libro de "Apuntes de Hormigón Armado" desarrolla los contenidos relacionados con el cálculo y comprobación de estructuras de edificación convencionales construidas en hormigón armado. Incluye los Estados Límite Últimos (piezas flectadas y flexo-comprimidas, cortante y punzonamiento, inestabilidad en pilares, redistribución limitada de momentos), Estados Límite de Servicio (fisuración y deformaciones instantáneas y diferidas), disposiciones constructivas de armaduras longitudinales y tangenciales y cálculo de elementos de cimentación y contención. La norma de referencia es la Instrucción Española de Hormigón Estructural, EHE-08, aunque también se reseña puntualmente el Eurocódigo 2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presentaciones de los temas que integran los contenidos de la asignatura "Estructuras Metálicas" impartidas en las titulaciones de Ing. Técnica de Obras Públicas y en el Grado en Ing. Civil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Material de apoyo de la asignatura "Estructuras Metálicas": prontuario de vigas y coeficientes de pandeo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Colección de problemas de la asignatura "Estructuras Metálicas" correspondientes a los estudios de Ing. Técnica de Obras Públicas y Grado en Ingeniería Civil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comunicación presentada en CONPAT 2011, XI Congreso Latinoamericano de Patología de la Construcción, Guatemala, octubre 2011.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En esta comunicación se presentan los estudios previos y las intervenciones realizadas en la iglesia de San Sebastián de Orihuela, Alicante (España) con el fin de subsanar los problemas estructurales que presentaba, con múltiples grietas en arcos y bóvedas y eliminar la humedad presente en sus fábricas, además de las sales aportadas por el agua. En el estudio histórico y arquitectónico se ha comprobado que la iglesia se construyó sobre una ermita gótica y se finalizó en 1743 pero ha sufrido numerosas intervenciones. Es una iglesia de nave única con capillas laterales cubierta mediante bóvedas. Su fachada y las pilastras interiores son de piedra vista. Para el diagnóstico se han empleado diversas técnicas (ultrasonidos, higrómetro…) que han permitido deducir las causas de las lesiones. Las intervenciones se han dirigido a reforzar la estructura mediante cosidos e inyecciones, así como a ventilar la base mediante un forjado sanitario. También se ha saneado la piedra vista, tanto en interior como en fachada y se han sacado a la luz los arcos de piedra ocultos bajo un estucado. También se han restaurado los restos arqueológicos de época gótica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No existe el fichero T10.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Como no existe la lección T10, tampoco hay ejercicios numerados como T10.xxx.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, several researchers have shown the good performance of alkali activated slag cement and concretes. Besides their good mechanical properties and durability, this type of cement is a good alternative to Portland cements if sustainability is considered. Moreover, multifunctional cement composites have been developed in the last decades for their functional applications (self-sensing, EMI shielding, self-heating, etc.). In this study, the strain and damage sensing possible application of carbon fiber reinforced alkali activated slag pastes has been evaluated. Cement pastes with 0, 0.29 and 0.58 vol % carbon fiber addition were prepared. Both carbon fiber dosages showed sensing properties. For strain sensing, function gage factors of up to 661 were calculated for compressive cycles. Furthermore, all composites with carbon fibers suffered a sudden increase in their resistivity when internal damages began, prior to any external signal of damage. Hence, this material may be suitable as strain or damage sensor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research, strain-sensing and damage-sensing functional properties of cement composites have been studied on a conventional reinforced concrete (RC) beam. Carbon nanofiber (CNFCC) and fiber (CFCC) cement composites were used as sensors on a 4 m long RC beam. Different casting conditions (in situ or attached), service location (under tension or compression) and electrical contacts (embedded or superficial) were compared. Both CNFCC and CFCC were suitable as strain sensors in reversible (elastic) sensing condition testing. CNFCC showed higher sensitivities (gage factor up to 191.8), while CFCC only reached gage factors values of 178.9 (tension) or 49.5 (compression). Furthermore, damage-sensing tests were run, increasing the applied load progressively up to the RC beam failure. In these conditions, CNFCC sensors were also strain sensitive, but no damage sensing mechanism was detected for the strain levels achieved during the tests. Hence, these cement composites could act as strain sensors, even for severe damaged structures near to their collapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Both strain and damage sensing properties on carbon nanofiber cement composites (CNFCC) are reported in the present paper. Strain sensing tests were first made on the material’s elastic range. The applied loading levels have been previously calculated from mechanical strength tests. The effect of several variables on the strain-sensing function was studied, e.g. cement pastes curing age, current density, loading rate or maximum stress applied. All these parameters were discussed using the gage factor as reference. After this first set of elastic experiments, the same specimens were gradually loaded until material’s failure. At the same time both strain and resistivity were measured. The former was controlled using strain gages, and the latter using a multimeter on a four probe setup. The aim of these tests was to prove the sensitivity of these CNF composites to sense their own damage, i.e. check the possibility of fabricating structural damage sensors with CNFCC’s. All samples with different CNF dosages showed good strain-sensing capacities for curing periods of 28 days. Furthermore, a 2%CNF reinforced cement paste has been sensitive to its own structural damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En la aplicación de la técnica de extracción electroquímica de cloruros (EEC), tradicionalmente se ha venido empleando como ánodo externo una malla de Ti-RuO2. En este artículo se aportan los resultados de investigaciones basadas en la utilización de ánodos formados por pasta de cemento conductora con adición de nanofibras de carbono (NFC) y su aplicación en EEC. Las experiencias se desarrollaron en probetas de hormigón contaminado previamente con cloruro. Las eficiencias alcanzadas se compararon con las obtenidas empleando un ánodo tradicional (Ti-RuO2), así como pastas de cemento con adición de otros materiales carbonosos. Los resultados muestran la viabilidad en la utilización de la pasta de cemento conductora con NFC como ánodo en la aplicación en EEC en hormigón, encontrándose eficiencias similares a las obtenidas con la tradicional malla de Ti-RuO2 pero teniendo la ventaja añadida sobre esta de que es posible adaptarla a geometrías estructurales complejas al ser aplicada en forma de pasta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El presente artículo se centra en la valorización de las cenizas de lodo de depuradora adicionadas en bloques de hormigón prefabricados, por tanto, en una matriz a base de cemento Portland con características particulares (consistencia seca). Se realiza una experiencia piloto mediante la fabricación de bloques en una planta industrial local, utilizando mezclas con porcentajes de sustitución de árido fino del 5, 10 y 15% por cenizas de lodo de depuradora, cuyos resultados se compararán con bloques de referencia (sin adición). Los ensayos aplicados son los preceptivos para su comercialización según normativa europea (marcado CE), lo que permitirá igualmente comprobar las características físicas y mecánicas de los hormigones. Los resultados obtenidos son prometedores: la utilización de este residuo permitiría su comercialización, mejora características de los bloques como la resistencia a compresión, y permitiría reducir un gran volumen de material utilizado habitualmente como materia prima y consumir un residuo destinado a vertedero.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Special foundations, most prominently micropiles and soil anchors, are frequently used in construction today. In Spain, the grout for these special technical applications is generally prepared with portland cement, although the codes and standards in place stipulate only the minimum compressive strength required, with no mention of cement type. Those texts also establish a range of acceptable water:cement ratios. In the present study, durability and compressive strength in cement grout prepared with blast furnace slag cement at different w/c ratios are characterised and compared to the findings for a reference portland cement grout. The results show that slag grout exhibits greater durability than the portland cement material and complies with the compressive strength requirements laid down in the respective codes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present paper, changes in mechanical properties of Portland cement-based mortars due to the addition of carbon nanotubes (CNT) and corrosion of embedded steel rebars in CNT cement pastes are reported. Bending strength, compression strength, porosity and density of mortars were determined and related to the CNT dosages. CNT cement paste specimens were exposed to carbonation and chloride attacks, and results on steel corrosion rate tests were related to CNT dosages. The increase in CNT content implies no significant variations of mechanical properties but higher steel corrosion intensities were observed.