4 resultados para Borings

em University of Washington


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Seattle Fault is an active east-west trending reverse fault zone that intersects both Seattle and Bellevue, two highly populated cities in Washington. Rupture along strands of the fault poses a serious threat to infrastructure and thousands of people in the region. Precise locations of fault strands are still poorly constrained in Bellevue due to blind thrusting, urban development, and/or erosion. Seismic reflection and aeromagnetic surveys have shed light on structural geometries of the fault zone in bedrock. However, the fault displaces both bedrock and unconsolidated Quaternary deposits, and seismic data are poor indicators of the locations of fault strands within the unconsolidated strata. Fortunately, evidence of past fault strand ruptures may also be recorded indirectly by fluvial processes and should also be observable in the subsurface. I analyzed hillslope and river geomorphology using LiDAR data and ArcGIS to locate surface fault traces and then compare/correlate these findings to subsurface offsets identified using borehole data. Geotechnical borings were used to locate one fault offset and provide input to a cross section of the fault constructed using Rockworks software. Knickpoints, which may correlate to fault rupture, were found upstream of this newly identified fault offset as well as upstream of a previously known fault segment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report presents the results of stratigraphic analysis of the southwestern quadrant of the Cedar Hills Regional Landfill (CHRLF). My report was intended to incorporate the recent Area 8 borehole data into the pre-existing analyses. This analysis was conducted during the preparation of the Area 8 Hydrogeologic Report, but is my independent investigation and does not represent the opinion of UEC or their associates. The CHRLF, in Maple Valley, WA, south of Squak Mountain, is a municipal solid waste landfill that has been in operation since the 1960s. A network of borings, the product of previous investigations, exists for the study area. I utilized the compiled boring logs, previous investigations, and the recently acquired data to produce a series of interpretative cross-sections for the study area. I recognized 9 distinct stratigraphic units, including fill. My interpreted stratigraphic units are similar to those identified in previous investigations such as the Area 7 Hydrogeologic investigation (HDR Engineering and Associates, 2008). These units include pre-Olympia aged non-glacial alluvium, glacial alluvium, and glacial till. Additionally, younger, Vashon-aged deposits of glacial till, recessional outwash, recessional lacustrine, and ice-contact were observed. An isolated “till-like” deposit was observed below the Vashon till. This could possibly represent an older till as mapped by Sweet Edwards (1985) and Booth (1995). I cite the continuity of the lower contact of the Vashon till (Unit 5, Table 2) and the upper contact pre-Vashon non-glacial fluvial deposits (Unit 9, Table 2) as evidence that faults or other structural features do not offset the deposits in the study area. This conclusion supports the findings of the pre-existing body of work within the landfill property and the nearby Queen City Farms property.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From October 2014 to March 2015, I provided excavation oversight services at a property with substantial environmental concerns. The property in question is located near downtown Seattle and was formerly occupied by the Washington’s first coal gasification plant. The plant operated from 1888 to 1908 and produced coal gas for municipal use. A coal tar like substance with a characteristically high benzene concentration was a byproduct of the coal gasification process and heavily contaminated at or below the surface grade of the plant as shown in previous investigations on the property. Once the plant ceased operation in 1908 the property was left vacant until 1955 when the site was filled in and a service station was built on the property. The main goal of the excavation was not to achieve cleanup on the property, but to properly remove what contaminated soil was encountered during the redevelopment excavation. Areas of concern were identified prior to the commencement of the excavation and an estimation of the extent of contamination on the property was developed. “Hot spots” of contaminated soil associated with the fill placed after 1955 were identified as areas of concern. However, the primary contaminant plume below the property was likely sourced from the coal gasification plant, which operated at an approximate elevation of 20 feet. We planned to constrain the extents of the soil contamination below the property as the redevelopment excavation progressed. As the redevelopment excavation was advanced down to an elevation of approximately 20 feet, soil samples were collected to bound the extents of contamination in the upper portion of the site. The hot spots, known pockets of carcinogenic polycyclic aromatic hydrocarbons (cPAH) located above 20 feet elevation, were excavated as part of the redevelopment excavation. Once a hot spot was excavated, soil samples were collected from the north, south, east, west and bottom sidewalls of the hot spot excavation to check for remaining cPAH. Additionally, four underground storage tanks (USTs) associated with the service station were discovered and subsequently removed. Soil samples were also collected from the resulting UST excavation sidewalls to check for remaining petroleum hydrocarbons. Once the excavation reached its final excavation depth of 20 to 16 feet in elevation, bottom of excavation samples were collected on a 35 foot by 35 foot grid to test for concentrations of contaminants remaining onsite. Once the redevelopment excavation was complete, soils observed from borings drilled for either structural elements, geotechnical wells, or environmental wells were checked for any evidence of contamination using field screening techniques. Evidence of contamination was used to identify areas below the final excavation grade which had been impacted by the operation of the coal gasification plant. Samples collected from the excavation extents of hot spots and USTs show that it was unlikely that any contamination traveled from the post-1955 grade down to the pre-1955 grade. Additionally, the lack of benzene in the bottom of excavation samples suggests that a release from the coal gasification plant occurred below the redevelopment excavation final elevations of 20 to 16 feet. Qualitative data collected from borings for shoring elements and wells indicated that the spatial extent of the subsurface contaminant plume was different than initially estimated. Observations of spoils show that soil contamination extends further to the southwest and not as far to the east and north than originally estimated. Redefining the extent of the soil contamination beneath the property will allow further subsurface investigations to focus on collecting quantitative data in areas that still represent data gaps on the property, and passing over areas that have shown little signs of contamination. This information will help with the formation of a remediation plan should the need to clean up the site arise in the future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is aimed at determining the spatial distribution, physical properties, and groundwater conditions of the Vashon advance outwash (Qva) in the Mountlake Terrace, WA area. The Qva is correlative with the Esperance Sand, as defined at its type section; however, local variations in the Qva are not well-characterized (Mullineaux, 1965). While the Qva is a dense glacial unit with low compressibility and high frictional shear strength (Gurtowski and Boirum, 1989), the strength of this unit can be reduced when it becomes saturated (Tubbs, 1974). This can lead to caving or flowing in excavations, and on a larger scale, can lead to slope failures and mass-wasting when intersected by steep slopes. By studying the Qva, we can better predict how it will behave under certain conditions, which will be beneficial to geologists, hydrogeologists, engineers, and environmental scientists during site assessments and early phases of project planning. In this study, I use data from 27 geotechnical borings from previous field investigations and C-Tech Corporation’s EnterVol software to create three-dimensional models of the subsurface geology in the study area. These models made it possible to visualize the spatial distribution of the Qva in relation to other geologic units. I also conducted a comparative study between data from the borings and generalized published data on the spatial distribution, relative density, soil classification, grain-size distribution, moisture content, groundwater conditions, and aquifer properties of the Qva. I found that the elevation of the top of the Qva ranges from 247 to 477 ft. I found that the Qva is thickest where the modern topography is high, and is thinnest where the topography is low. The thickness of the Qva ranges from absent to 242 ft. Along the northern, east-west trending transect, the Qva thins to the east as it rises above a ridge composed of Pre- Vashon glacial deposits. Along the southern, east-west trending transect, the Qva pinches out against a ridge composed of pre-Vashon interglacial deposits. Two plausible explanations for this ridge are paleotopography and active faulting associated with the Southern Whidbey Fault Zone. Further investigations should be done using geophysical methods and the modeling methods described in this study to determine the nature of this ridge. The relative density of the Qva in the study area ranges from loose to very dense, with the loose end of the spectrum probably relating to heave in saturated sands. I found subtle correlations between density and depth. Volumetric analysis of the soil groups listed in the boring logs indicate that the Qva in the study area is composed of approximately 9.5% gravel, 89.3% sand, and 1.2% silt and clay. The natural moisture content ranges from 3.0 to 35.4% in select samples from the Qva. The moisture content appears to increase with depth and fines content. The water table in the study area ranges in elevation from 231.9 to 458 ft, based on observations and measurements recorded in the boring logs. The results from rising-head and falling-head slug tests done at a single well in the study area indicate that the geometric mean of hydraulic conductivity is 15.93 ft/d (5.62 x 10-03 cm/s), the storativity is 3.28x10-03, and the estimated transmissivity is 738.58 ft2/d in the vicinity of this observation well. At this location, there was 1.73 ft of seasonal variation in groundwater elevation between August 2014 and March 2015.