2 resultados para units samples

em University of Queensland eSpace - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite recent reports of clonal strains of Pseudomonas aeruginosa in cystic fibrosis (CF) units, the need for routine microbiological surveillance remains contentious. Sputum was collected prospectively from productive patients attending the regional paediatric and adult CF units in Brisbane, Australia. All P. aeruginosa isolates were typed using pulsed-field gel electrophoresis. Spirometry, anthropometrics, hospitalisations and antibiotic sensitivity data were recorded. The first 100 sputum samples (first 50 patients at each clinic) harboured 163 isolates of P. aeruginosa. A total of 39 patients shared a common strain (pulsotype 2), 20 patients shared a strain with at least one other patient and 41 patients harboured unique strains. Eight patients shared a strain identical to a previously reported Australian transmissible strain (pulsotype 1). Compared with the unique strain group, patients harbouring pulsotype 2 were younger and had poorer lung function. Treatment requirements were similar in these two groups, as were the rates of multiresistance. In conclusion, 59% of patients harboured a clonal strain, supporting the need for routine microbiological surveillance. In contrast to previously described clonal strains, the dominant pulsotype was indistinguishable from nonclonal strains with respect to both colonial morphology and multiresistance. The clinical significance of clonal strains remains uncertain and requires longitudinal study.