5 resultados para transient evoked otoaccoustic emissions

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study investigated body position effects on transient evoked otoacoustic emission (TEOAE) recordings of clinical significance. Sixty adults (30 males, 30 females) were assessed using the Otodynamics ILO88 Analyzer in three positions (sitting, supine, and side-lying). Results indicated significant positional effects on the TEOAE parameters of A-B difference, noise, whole wave reproducibility, and response levels. These differences included higher noise levels in supine and side-lying positions in comparison to the upright sitting position. Lower whole wave reproducibility measurements, and higher response amplitudes, in the side-lying position compared with supine and seated positions were also observed. No significant effects were evident for signal-to-noise ratio or band reproducibility. Given the lack of significant body position effects on these latter parameters and the infrequent clinical use of the other parameters in isolation, there was no evidence to suggest the future need for major review of current pass/fail criteria or of the standard test protocol.