178 resultados para tooth-coil winding
em University of Queensland eSpace - Australia
Resumo:
A method is presented for calculating the currents and winding patterns required to design independent zonal and tesseral shim coils for magnetic resonance imaging. Both actively shielded and unshielded configurations are considered, and the region of interest can be located asymmetrically with respect to the coil's length. Streamline, target-field and Fourier-series methods are utilized. The desired target-field is specified at two cylindrical radii, on and inside a circular conducting cylinder of length 2L and radius a. The specification is over some asymmetric portion pL < z < qL of the coil's length (-1 < p < q < 1). Arbitrary functions are used in the outer sections, -L < z < pL and qL < z < L, to ensure continuity of the magnetic field across the entire length of the coil. The entire field is then periodically extended as a half-range cosine Fourier series about either end of the coil. The resultant Fourier coefficients are then substituted into the Fourier-series expressions for the internal and external magnetic fields, and current densities and stream functions on both the primary coil and shield. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis and shielding analysis on field calculations from a ZX shim coil indicate that example designs and theory are well matched.
Resumo:
A method is presented for calculating the winding patterns required to design independent zonal and tesseral biplanar shim coils for magnetic resonance imaging. Streamline, target-field, Fourier integral and Fourier series methods are utilized. For both Fourier-based methods, the desired target field is specified on the surface of the conducting plates. For the Fourier series method it is possible to specify the target field at additional depths interior to the two conducting plates. The conducting plates are confined symmetrically in the xy plane with dimensions 2a x 2b, and are separated by 2d in the z direction. The specification of the target field is symmetric for the Fourier integral method, but can be over some asymmetric portion pa < x < qa and sb < y < tb of the coil dimensions (-1 < p < q < 1 and -1 < s < t < 1) for the Fourier series method. Arbitrary functions are used in the outer sections to ensure continuity of the magnetic field across the entire coil face. For the Fourier series case, the entire field is periodically extended as double half-range sine or cosine series. The resultant Fourier coefficients are substituted into the Fourier series and integral expressions for the internal and external magnetic fields, and stream functions on both the conducting surfaces. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis of field calculations from a ZX shim coil indicates that example designs and theory are well matched.
Resumo:
Time-harmonic methods are required in the accurate design of RF coils as operating frequency increases. This paper presents such a method to find a current density solution on the coil that will induce some desired magnetic field upon an asymmetrically located target region within. This inverse method appropriately considers the geometry of the coil via a Fourier series expansion, and incorporates some new regularization penalty functions in the solution process. A new technique is introduced by which the complex, time-dependent current density solution is approximated by a static coil winding pattern. Several winding pattern solutions are given, with more complex winding patterns corresponding to more desirable induced magnetic fields.
Resumo:
In a magnetic resonance imaging equipment, gradient and shim coils are needed to produce a spatially varying magnetic field throughout the sample being imaged. Such coils consist of turns of wire wound on the surface of a cylindrical tube. Shim coils in particular, must sometimes be designed to produce complicated magnetic fields to correct for impurities. Streamline patterns for shim coils are much more complicated than those for gradient coils, In this work we present a detailed analysis of streamline methods and their application to shim coil design, A method is presented for determining the winding patterns to generate these complicated fields. (C) 2002 John Wiley & Sons, Inc.
Resumo:
In this work a new approach for designing planar gradient coils is outlined for the use in an existing MRI apparatus. A technique that allows for gradient field corrections inside the diameter-sensitive volume is deliberated. These corrections are brought about by making changes to the wire paths that constitute the coil windings, and hence, is called the path correction method. The existing well-known target held method is used to gauge the performance of a typical gradient coil. The gradient coil design methodology is demonstrated for planar openable gradient coils that can be inserted into an existing MRI apparatus. The path corrected gradient coil is compared to the coil obtained using the target field method. It is shown that using a wire path correction with optimized variables, winding patterns that can deliver high magnetic gradient field strengths and large imaging regions can be obtained.
Resumo:
A rapid spherical harmonic calculation method is used for the design of Nuclear Magnetic Resonance shim coils. The aim is to design each shim such that it generates a field described purely by a single spherical harmonic. By applying simulated annealing techniques, coil arrangements are produced through the optimal positioning of current-carrying circular arc conductors of rectangular cross-section. This involves minimizing the undesirable harmonies in relation to a target harmonic. The design method is flexible enough to be applied for the production of coil arrangements that generate fields consisting significantly of either zonal or tesseral harmonics. Results are presented for several coil designs which generate tesseral harmonics of degree one.
Resumo:
Polydnaviruses are associated with certain parasitoid wasps and are introduced into the body cavity of the host caterpillar during oviposition. Some of the viral genes are expressed in host tissues and corresponding proteins are secreted into the hemocoel causing suppression of the host immune system. The Cotesia rubecula polydnavirus gene product, CrV1, effectively inactivates hemocytes by mediating cytoskeleton break-down. A precondition for the CrV1 function is the incorporation of the extracellular protein by hemocytes. Here, we show that a coiled-coil domain containing a putative leucine zipper is required for CrV1 function, since removal of this domain abolishes binding and uptake of the CrV1 protein by hemocytes. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Most lungfish tooth plates, that are arranged in radiating ridges derived from the fusion of separate cusps in young juveniles, are based on a framework of enamel, mantle dentine and bone that encloses a mass of specialized dentines forming the occlusal surface. In most taxa, the specialized dentines are interdenteonal and circumdenteonal dentine, but a few derived genera have petrodentine as well. Petrodentine, as originally defined, describes a specific form of hypermineralized dentine in adult tooth plates of the Recent African lungfish Protopterus. The ontogeny of fossil and Recent lungfish tooth plates demonstrates that petrodentine is derived by continuous enhancement of the hard tissue of the primary core of the initially isolated cusps of the tooth plate, and that interdenteonal dentine with denteons of circumdenteonal dentine is a secondary development in the tooth plate around and below the first formed cusps of the ridges. In dipnoans that lack petrodentine in adults the primary core of the cusps is not enhanced, but is removed by wear. The hard tissues of the dipnoan tooth plate provide useful characters for defining dipnoan taxa, as do the differing arrangements of the tissues in each species. Details of the arrangement of the enclosed specialized dentines are surprisingly variable among genera, and are significant for the structure and function of the tooth plate. Little regularity of structure is discernible in the histology of tooth plates of early dipnoans, but derived genera have more predictable structure. Consistent with other uniquely dipnoan characters, like the composition of the dermal skull, an evolutionary progression is evident within the group in the fine structure of the dentition, and, as with the bones of the dermal skull, little similarity is demonstrable between the dentines of dipnoans and tetrapods.
Resumo:
Four cases-of congenital dysfunction of the major salivary glands as well as of Prader-Willi, congenital rubella, and Sjogren's syndromes-were identified in a series of 500 patients referred for excessive tooth wear. Although there was evidence of consumption of highly acidic drinks, some occlusal parafunction, and unacceptable toothbrushing habits, salivary dysfunction was the salient factor predisposing a patient to tooth wear in these syndromal cases. The 500 subjects have been characterized either as having medical conditions and medications that predispose them to xerostomia or lifestyles in which workplace- and sports-related dehydration lead to reduced salivary flow. Normal salivation, by buffering capacity, clearance by swallowing, pellicle formation, and capacity for remineralization of demineralized enamel, protects the teeth from extrinsic and intrinsic acids that initiate dental erosion. Thus, the syndromes, unrelated in many respects, underline the importance of normal salivation in the protection of teeth against tooth wear by erosion, attrition, and abrasion.
Resumo:
This review illustrates, through a series of case histories, how oral medicine insights aid the diagnosis and management of patients with excessive tooth wear. The cases reviewed are drawn from the records of 500 southeast Queensland patients referred to the author over a 12 year period. Patients most at risk of dental erosion have work and sports dehydration, caffeine addiction, gastro-oesophageal reflux, asthma, diabetes mellitus, hypertension or other systemic diseases or syndromes that predispose to xerostomia. Saliva protects the teeth from the extrinsic and intrinsic acids which cause dental erosion. Erosion, exacerbated by attrition and abrasion, is the main cause of tooth wear. These cases illustrate that teeth, oral mucosa, salivary glands, skin and eyes should be examined for evidence of salivary hypofunction and attendant medical conditions. Based on comprehensive oral medicine, dietary analyses and advice, it would seem patients need self-management plans to deal with incipient chronic tooth wear. The alternative is the expensive treatment of pain, occlusal damage and pulp death required to repair the effects of acute severe tooth wear.
Resumo:
Bone remodeling during tooth movement is regulated by local and systemic factors. Two regulators of bone metabolism are growth hormone (GH) and insulin-like growth factor-I (IGF-1). Their effects are mediated via binding to GH receptor (GHR) and IGF-I receptor (IGF-IR) in target tissues. Corticosteroids may affect the activity of these growth factors. This study examined the effect of prednisolone on GHR and IGF-IR expression in dental tissues following orthodontic tooth movement. The corti ticosteroid-treated group (N = 6) was administered prednisolone ( 1 mg/kg,) daily and the control group (N = 6) received equivalent volumes of saline. An orthodontic force (30 g) was applied to the maxillary first molar. Animals were sacrificed 12 days postappliance insertion. Sagittal sections of the first molar were stained for GHR and IGF-IR immunoreactivity. GHR and IGF-IR cell counts were elevated following appliance-treatment. Orthodontic tooth movement appeared to up-regulate GHR and IGF-IR immunoreactivity, but this up-regulation was reduced following prednisolone treatment. The suppression of GHR and IGF-I immunoreactivity in steroid-treated animals infers the mechanism whereby bone resorption and deposition, necessary for orthodontic tooth movement, may be inhibited by prednisolone. However, at 12 days postappliance insertion. no difference in orthodontic tooth movement was observed following low-dose prednisolone treatment.
Resumo:
This paper presents a new approach for the design of genuinely finite-length shim and gradient coils, intended for use in magnetic resonance imaging equipment. A cylindrical target region is located asymmetrically, at an arbitrary position within a coil of finite length. A desired target field is specified on the surface of that region, and a method is given that enables winding patterns on the surface of the coil to be designed, to produce the desired field at the inner target region. The method uses a minimization technique combined with regularization, to find the current density on the surface of the coil. The method is illustrated for linear, quadratic and cubic magnetic target fields located asymmetrically within a finite-length coil.