10 resultados para therapeutic monitoring
em University of Queensland eSpace - Australia
Resumo:
Aim To develop a population pharmacokinetic model for mycophenolic acid in adult kidney transplant recipients, quantifying average population pharmacokinetic parameter values, and between- and within-subject variability and to evaluate the influence of covariates on the pharmacokinetic variability. Methods Pharmacokinetic data for mycophenolic acid and covariate information were previously available from 22 patients who underwent kidney transplantation at the Princess Alexandra Hospital. All patients received mycophenolate mofetil 1 g orally twice daily. A total of 557 concentration-time points were available. Data were analysed using the first-order method in NONMEM (version 5 level 1.1) using the G77 FORTRAN compiler. Results The best base model was a two-compartment model with a lag time (apparent oral clearance was 271 h(-1), and apparent volume of the central compartment 981). There was visual evidence of complex absorption and time-dependent clearance processes, but they could not be successfully modelled in this study. Weight was investigated as a covariate, but no significant relationship was determined. Conclusions The complexity in determining the pharmacokinetics of mycophenolic acid is currently underestimated. More complex pharmacokinetic models, though not supported by the limited data collected for this study, may prove useful in the future. The large between-subject and between-occasion variability and the possibility of nonlinear processes associated with the pharmacokinetics of mycophenolic acid raise questions about the value of the use of therapeutic monitoring and limited sampling strategies.
Resumo:
Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.
Resumo:
The aim of this study was to determine the most informative sampling time(s) providing a precise prediction of tacrolimus area under the concentration-time curve (AUC). Fifty-four concentration-time profiles of tacrolimus from 31 adult liver transplant recipients were analyzed. Each profile contained 5 tacrolimus whole-blood concentrations (predose and 1, 2, 4, and 6 or 8 hours postdose), measured using liquid chromatography-tandem mass spectrometry. The concentration at 6 hours was interpolated for each profile, and 54 values of AUC(0-6) were calculated using the trapezoidal rule. The best sampling times were then determined using limited sampling strategies and sensitivity analysis. Linear mixed-effects modeling was performed to estimate regression coefficients of equations incorporating each concentration-time point (C0, C1, C2, C4, interpolated C5, and interpolated C6) as a predictor of AUC(0-6). Predictive performance was evaluated by assessment of the mean error (ME) and root mean square error (RMSE). Limited sampling strategy (LSS) equations with C2, C4, and C5 provided similar results for prediction of AUC(0-6) (R-2 = 0.869, 0.844, and 0.832, respectively). These 3 time points were superior to C0 in the prediction of AUC. The ME was similar for all time points; the RMSE was smallest for C2, C4, and C5. The highest sensitivity index was determined to be 4.9 hours postdose at steady state, suggesting that this time point provides the most information about the AUC(0-12). The results from limited sampling strategies and sensitivity analysis supported the use of a single blood sample at 5 hours postdose as a predictor of both AUC(0-6) and AUC(0-12). A jackknife procedure was used to evaluate the predictive performance of the model, and this demonstrated that collecting a sample at 5 hours after dosing could be considered as the optimal sampling time for predicting AUC(0-6).
Resumo:
Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.
Resumo:
Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and
Resumo:
Lamotrigine concentrations were measured simultaneously (as far as was feasible) in stimulated and unstimulated saliva samples, and in plasma, from seven adult volunteers over a 32 h period following a single 50 mg dose of the drug, and in 20 children and adolescents during the course of routine antiepileptic therapy. In individuals there was a close correlation between the measurements at least 2 It after ingestion of the drug. Concentrations in stimulated and unstimulated saliva were similar; the stimulation produced little change in the saliva secretion rate. The saliva-to-plasma concentration ratio increased linearly by 0.78% for each 1 mg/L plasma lamotrigine concentration, with a mean value of 48.8% at a plasma lamotrigine concentration of 10 mg/L. With appropriate precautions as to the timing of saliva collections, and a single plasma lamotrigine concentration measurement to calibrate the salivary values in the individual, salivary lamotrigine concentration measurement appears to be a practicable approach to therapeutic drug monitoring. This has significant implications for the elucidation of the pharmacokinetics of lamotrigine in the paediatric population.