3 resultados para sonar distance measurement
em University of Queensland eSpace - Australia
Resumo:
Conventional detection scheme for self-mixing sensors uses an integrated photodiode within the laser package to monitor the self mixing signal. This arrangement can be simplified by directly obtaining the self-mixing signals across the laser diode itself and omitting the photodiode. This work reports on a Vertical-Cavity Surface-Emitting Laser (VCSEL) based selfmixing sensor using the laser junction voltage to obtain the selfmixing signal. We show that the same information can be obtained with only minor changes to the extraction circuitry leading to potential cost saving with reductions in component costs and complexity and significant increase in bandwidth favoring high speed modulation. Experiments using both photo current and voltage detection were carried out and the results obtained show good agreement with the theory.
Resumo:
Stickiness behavior of skim milk powder was investigated based on the mechanical property of the material during the glass-rubber transition. A thermally controlled device was developed for the static mechanical test. This device was attached to a texture analyzer, and skim milk powder, which was used as a model sample, was tested for its glass-rubber transition temperature (Tg-r) using static compression technique (creep test). Changes in compression probe distance as a function of temperature were recorded. Tg-r was determined, in the region where changes in the probe distance were observed, by using linear regression technique. The effect of sample quantity, compression force, and heating rate on the determination of Tg-r was investigated. All these parameters significantly influenced the Tg-r determination (p < 0.05). The Tg-r of skim milk powder measured by this novel technique was found closely correlated to its glass transition temperature (T-g) measured by DSC.
Resumo:
Background. Previous studies have identified no strong correlation between patients' height and tracheal length in anaesthetized patients. We have attempted to compare vocal cords-carina distance (VCD) in Chinese patients with the dimensions of five commonly used tracheal tubes. In addition, we attempted to find a surface anatomy measurement that would identify patients with 'short tracheas'. Methods. We measured VCD in 130 anaesthetized Chinese patients with a fibreoptic bronchoscope. Also measurements were obtained of the distal ends of five commonly used tracheal tubes. We undertook various surface anatomy measurements on the patients' chest and neck region to predict those patients with short tracheas. Results. VCD averaged 12.6 ((SD) 1.4) cm. In seven patients (5%) this distance was particularly short (between 8.8 and 10.4 cm). Many of the commonly used tracheal tubes would be placed close to or beyond the carina when the black intubation guide mark(s) is (are) at the level of the vocal cords. The VCD of