4 resultados para sinusoidal phase modulating interferometer

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantum optics experiments on bright beams are based on the spectral analysis of field fluctuations and typically probe correlations between radio-frequency sideband modes. However, the extra degree of freedom represented by this dual-mode picture is generally ignored. We demonstrate the experimental operation of a device which can be used to separate the quantum sidebands of an optical field. We use this device to explicitly demonstrate the quantum entanglement between the sidebands of a squeezed beam.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate resonant tunnelling through molecular states of an Aharonov-Bohm (AB) interferometer composed of two coupled quantum dots. The conductance of the system shows two resonances associated with the bonding and the antibonding quantum states. We predict that the two resonances are composed of a Breit-Wigner resonance and a Fano resonance, of which the widths and Fano factor depend on the AB phase very sensitively. Further, we point out that the bonding properties, such as the covalent and ionic bonding, can be identified by the AB oscillations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Binocular rivalry occurs when different images are presented simultaneously to corresponding points within the left and right eyes. Under these conditions, the observer's perception will alternate between the two perceptual alternatives. Motivated by the reported link between the rate of perceptual alternations, symptoms of psychosis and an incidental observation that the rhythmicity of perceptual alternations during binocular rivalry was greatly increased 10 h after the consumption of LSD, this study aimed to investigate the pharmacology underlying binocular rivalry and to explore the connection between the timing of perceptual switching and psychosis. Psilocybin (4-phosphoryloxy-N,N-dimethyltryptamine, PY) was chosen for the study because, like LSD, it is known to act as an agonist at serotonin (5-HT)(1A) and 5-HT2A receptors and to produce an altered state sometimes marked by psychosis-like symptoms. A total of 12 healthy human volunteers were tested under placebo, low-dose ( 115 mg/kg) and high-dose ( 250 mg/kg) PY conditions. In line with predictions, under both low- and high-dose conditions, the results show that at 90 min postadministration ( the peak of drug action), rate and rhythmicity of perceptual alternations were significantly reduced from placebo levels. Following the 90 min testing period, the perceptual switch rate successively increased, with some individuals showing increases well beyond pretest levels at the final testing, 360 min postadministration. However, as some subjects had still not returned to pretest levels by this time, the mean phase duration at 360 min was not found to differ significantly from placebo. Reflecting the drug-induced changes in rivalry phase durations, subjects showed clear changes in psychological state as indexed by the 5D-ASC ( altered states of consciousness) rating scales. This study suggests the involvement of serotonergic pathways in binocular rivalry and supports the previously proposed role of a brainstem oscillator in perceptual rivalry alternations and symptoms of psychosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a class of compact, fluid-based, interferometric, tunable optical components: the single-beam microfluidic Mach-Zender interferometer. Phase delay is achieved through light propagation across a fluid-air interface (meniscus). The effect of meniscus curvature on the device transmission is considered using the three-dimensional beam propagation method and shown to be an important device parameter. We engineer the meniscus curvature using monomer surface chemistry, rendering it flat, and find that the experimental response corresponds well with simulation. The device has a resonance at 1.3 mum with a 25 dB extinction ratio; the latter can be adjusted by shifting the meniscus position.