11 resultados para rosin sizing
em University of Queensland eSpace - Australia
Resumo:
A technique based on laser light diffraction is shown to be successful in collecting on-line experimental data. Time series of floc size distributions (FSD) under different shear rates (G) and calcium additions were collected. The steady state mass mean diameter decreased with increasing shear rate G and increased when calcium additions exceeded 8 mg/l. A so-called population balance model (PBM) was used to describe the experimental data, This kind of model describes both aggregation and breakage through birth and death terms. A discretised PBM was used since analytical solutions of the integro-partial differential equations are non-existing. Despite the complexity of the model, only 2 parameters need to be estimated: the aggregation rate and the breakage rate. The model seems, however, to lack flexibility. Also, the description of the floc size distribution (FSD) in time is not accurate.
Resumo:
Due to the complexities involved with measuring activated sludge floc size distributions, this parameter has largely been ignored by wastewater researchers and practitioners. One of the major reasons has been that instruments able to measure particle size distributions were complex, expensive and only provided off-line measurements. The Focused Beam Reflectance Method (FBRM) is one of the rare techniques able to measure the particle size distribution in situ. This paper introduces the technique for monitoring wastewater treatment systems and compares its performance with other sizing techniques. The issue of the optimal focal point is discussed, and similar conclusions as found in the literature for other particulate systems are drawn. The study also demonstrates the capabilities of the FBRM in evaluating the performance of settling tanks. Interestingly, the floc size distributions did not vary with position inside the settling tank flocculator. This was an unexpected finding, and seriously questioned the need for a flocculator in the settling tank. It is conjectured that the invariable size distributions were caused by the unique combination of high solids concentration, low shear and zeolite dosing. (C) 2004 Society of Chemical Industry.
Resumo:
This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Typical disturbances of biological environment such as background scatter and refractive index variations have little effect on the size-dependent scattering property of highly refractive nanocrystals, which are potentially attractive optical labels. We report on what is to our knowledge the first investigation of these scattering optical labels, and their sizing, in particular, by imaging at subvideo frame rates and analyzing samples of diamond nanocrystals deposited on a glass substrate in air and in a matrix of weakly scattering polymer. The brightness of a diffraction-limited spot appears to serve as a reliable measure of the particle size in the Rayleigh scattering limit. (c) 2006 Optical Society of America.
Resumo:
Rates of cell size increase are an important measure of success during the baculovirus infection process. Batch and fed batch cultures sustain large fluctuations in osmolarity that can affect the measured cell volume if this parameter is not considered during the sizing protocol. Where osmolarity differences between the sizing diluent and the culture broth exist, biased measurements of size are obtained as a result of the cell osmometer response. Spodoptera frugiperda (Sf9) cells are highly sensitive to volume change when subjected to a change in osmolarity. Use of the modified protocol with culture supernatants for sample dilution prior to sizing removed the observed error during measurement.
Resumo:
This paper delineates the development of a prototype hybrid knowledge-based system for the optimum design of liquid retaining structures by coupling the blackboard architecture, an expert system shell VISUAL RULE STUDIO and genetic algorithm (GA). Through custom-built interactive graphical user interfaces under a user-friendly environment, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking, and member sizing optimization. For structural optimization, GA is applied to the minimum cost design of structural systems with discrete reinforced concrete sections. The design of a typical example of the liquid retaining structure is illustrated. The results demonstrate extraordinarily converging speed as near-optimal solutions are acquired after merely exploration of a small portion of the search space. This system can act as a consultant to assist novice designers in the design of liquid retaining structures.
Resumo:
This paper describes a coupled knowledge-based system (KBS) for the design of liquid-retaining structures, which can handle both the symbolic knowledge processing based on engineering heuristics in the preliminary synthesis stage and the extensive numerical crunching involved in the detailed analysis stage. The prototype system is developed by employing blackboard architecture and a commercial shell VISUAL RULE STUDIO. Its present scope covers design of three types of liquid-retaining structures, namely, a rectangular shape with one compartment, a rectangular shape with two compartments and a circular shape. Through custom-built interactive graphical user interfaces, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking and member sizing optimization. It is also integrated with various relational databases that provide the system with sectional properties, moment and shear coefficients and final member details. This system can act as a consultant to assist novice designers in the design of liquid-retaining structures with increase in efficiency and optimization of design output and automated record keeping. The design of a typical example of the liquid-retaining structure is also illustrated. (C) 2003 Elsevier B.V All rights reserved.
Resumo:
Nitrogen adsorption at 77 K is the current standard means for pore size determination of adsorbent materials. However, nitrogen adsorption reaches limitations when dealing with materials such as molecular sieving carbon with a high degree of ultramicroporosity. In this investigation, methane and carbon dioxide adsorption is explored as a possible alternative to the standard nitrogen probe. Methane and carbon dioxide adsorption equilibria and kinetics are measured in a commercially derived carbon molecular sieve over a range of temperatures. The pore size distribution is determined from the adsorption equilibrium, and the kinetics of adsorption is shown to be Fickian for carbon dioxide and non-Fickian for methane. The non-Fickian response is attributed to transport resistance at the pore mouth experienced by the methane molecules but not by the carbon dioxide molecules. Additionally, the change in the rate of adsorption with loading is characterized by the Darken relation in the case of carbon dioxide diffusion but is greater than that predicted by the Darken relation for methane transport. Furthermore, the proposition of inkbottle-shaped micropores in molecular sieving carbon is supported by the determination of the activation energy for the transport of methane and subsequent sizing of the pore-mouth barrier by molecular potential calculations.
Resumo:
Cylpebs are slightly tapered cylindrical grinding media with a ratio of length to diameter of unity. The manufactures have made conflicting claims regarding the milling performance of Cylpebs in comparison with balls. One major point of interest is which one grinds finer at the same operating conditions. The difficulty in comparison is due to the shape difference. The two grinding media have different surface area, bulk density and contact mechanisms in grinding action. Comparative tests were conducted using the two types of grinding media in a laboratory Bond ball mill at various conditions of equality such as media mass, size distribution, surface area and input specific energy. The laboratory results indicate that at the same specific energy input level the Cylpebs produce a product with slightly less oversize due to their greater surface area, but essentially the same sizing at the fine end as that produced with the balls. The reason may be that the advantage of greater surface area is balanced by the line contact and area contact grinding actions with the Cylpebs. A new ball mill scale-up procedure [Man, Y.T., 2001. Model-based procedure for scale-up of wet, overflow ball mills, Part 1: outline of the methodology. Minerals Engineering 14 (10), 1237-1246] was employed to predict grinding performance of an industrial mill from the laboratory test results. The predicted full scale operation was compared with the plant survey data. Some problems in the original scale-up procedures were identified. The scale-up procedure was therefore modified to allow the predicted ball mill performance to match the observed one. The calibrated scale-up procedure was used to predict the Cylpebs performance in the full scale industrial mill using the laboratory tests results. (C) 2004 Elsevier Ltd. All rights reserved.