24 resultados para rapid diagnostic test

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rising costs of antimalarial agents are increasing the demand for accurate diagnosis of malaria. Rapid diagnostic tests (RDTs) offer great potential to improve the diagnosis of malaria, particularly in remote areas. Many RDTs are based on the detection of Plasmodium falciparum histidine-rich protein (PfHRP) 2, but reports from field tests have questioned their sensitivity and reliability. We hypothesize that the variability in the results of PfHRP2-based RDTs is related to the variability in the target antigen. We tested this hypothesis by examining the genetic diversity of PfHRP2, which includes numerous amino acid repeats, in 75 P. falciparum lines and isolates originating from 19 countries and testing a subset of parasites by use of 2 PfHRP2-based RDTs. We observed extensive diversity in PfHRP2 sequences, both within and between countries. Logistic regression analysis indicated that 2 types of repeats were predictive of RDT detection sensitivity (87.5% accuracy), with predictions suggesting that only 84% of P. falciparum parasites in the Asia-Pacific region are likely to be detected at densities

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Article Right arrow Full Text Right arrow Full Text (PDF) Right arrow Supplemental material Right arrow Alert me when this article is cited Right arrow Alert me if a correction is posted Services Right arrow Similar articles in this journal Right arrow Similar articles in PubMed Right arrow Alert me to new issues of the journal Right arrow Download to citation manager Right arrow Reprints and Permissions Right arrow Copyright Information Right arrow Books from ASM Press Right arrow MicrobeWorld Citing Articles Right arrow Citing Articles via HighWire Right arrow Citing Articles via Google Scholar Google Scholar Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Search for Related Content PubMed Right arrow PubMed Citation Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Pubmed/NCBI databases * Substance via MeSH Previous Article | Next Article Journal of Clinical Microbiology, August 2006, p. 2773-2778, Vol. 44, No. 8 0095-1137/06/$08.00+0 doi:10.1128/JCM.02557-05 Copyright © 2006, American Society for Microbiology. All Rights Reserved. Effect of Sequence Variation in Plasmodium falciparum Histidine- Rich Protein 2 on Binding of Specific Monoclonal Antibodies: Implications for Rapid Diagnostic Tests for Malaria{dagger} Nelson Lee,1,2 Joanne Baker,2 Kathy T. Andrews,1 Michelle L. Gatton,1,3 David Bell,4 Qin Cheng,2,3 and James McCarthy1* Australian Centre for International and Tropical Health and Nutrition, Queensland Institute of Medical Research and School of Population Health, University of Queensland, Queensland, Australia,1 Department of Drug Resistance and Diagnostics, Australian Army Malaria Institute, Brisbane, Australia,2 Malaria Drug Resistance and Chemotherapy, Queensland Institute of Medical Research, Queensland, Australia,3 World Health Organization, Regional Office for the Western Pacific, Manila, Philippines4 Received 8 December 2005/ Returned for modification 23 February 2006/ Accepted 26 May 2006 The ability to accurately diagnose malaria infections, particularly in settings where laboratory facilities are not well developed, is of key importance in the control of this disease. Rapid diagnostic tests (RDTs) offer great potential to address this need. Reports of significant variation in the field performance of RDTs based on the detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) (PfHRP2) and of significant sequence polymorphism in PfHRP2 led us to evaluate the binding of four HRP2-specific monoclonal antibodies (MABs) to parasite proteins from geographically distinct P. falciparum isolates, define the epitopes recognized by these MABs, and relate the copy number of the epitopes to MAB reactivity. We observed a significant difference in the reactivity of the same MAB to different isolates and between different MABs tested with single isolates. When the target epitopes of three of the MABs were determined and mapped onto the peptide sequences of the field isolates, significant variability in the frequency of these epitopes was observed. These findings support the role of sequence variation as an explanation for variations in the performance of HRP2-based RDTs and point toward possible approaches to improve their diagnostic sensitivities

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Posttransplantation diabetes (PTD) contributes to cardiovascular disease and graft loss in renal transplant recipients (RTR). Current recommendations advise fasting blood glucose (FBG) as the screening and diagnostic test of choice for PTD. This study sought to determine (1) the predictive power of FBG with respect to 2-h blood glucose (2HBG) and (2) the prevalence of PTD using FBG and 2HBG compared with that using FBG alone, in prevalent RTR. A total of 200 RTR (mean age 52 yr; 59% male; median transplant duration 6.6 yr) who were >6 mo posttransplantation and had no known history of diabetes were studied. Patients with FBG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The identification of biomarkers capable of providing a reliable molecular diagnostic test for prostate cancer (PCa) is highly desirabie clinically. We describe here 4 biomarkers, UDP-N-Acetyl-alpha-D-galactosamine transferase (GalNAc-T3; not previously associated with PCa), PSMA, Hepsin and DD3/PCA3, which, in combination, distinguish prostate cancer from benign prostate hyperplasia (BPH). GalNAc-T3 was identified as overexpressed in PCa tissues by microarray analysis, confirmed by quantitative real-time PCR and shown immunohistochemically to be localised to prostate epithelial cells with higher expression in malignant cells. Real-time quantitative PCR analysis across 21 PCa and 34 BPH tissues showed 4.6-fold overexpression of GalNAc-T3 (p = 0.005). The noncoding mRNA (DD3/PCA3) was overexpressed 140-fold (p = 0.007) in the cancer samples compared to BPH tissues. Hepsin was overexpressed 21-fold (p = 0.049, whereas the overexpression for PSMA was 66-fold (p = 0.047). When the gene expression data for these 4 biomarkers was combined in a logistic regression model, a predictive index was obtained that distinguished 100% of the PCa samples from all of the BPH samples. Therefore, combining these genes in a real-time PCR assay represents a powerful new approach to diagnosing PCa by molecular profiling. (c) 2005 Wiley-Liss, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the 60 years since C H Li reported the isolation of bovine growth hormone (GH), endocrinologists have seen the widespread use of human GH for statural disorders, the measurement of plasma GH as a diagnostic test, the full development of the somatomedin hypothesis and the molecular details of the function of the GH receptor responsible for regulating somatic growth and metabolism. In diabetes, we have passed from administration of animal insulin to formulations with different release rates, insulin pumps and inhalers, insulin sensitizers and a greater understanding of insulin signalling and insulin resistance through genetically engineered murine models. What might we expect over the next few decades?

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and Objective: To describe the diagnostic accuracy and practical application of the Peter James Centre Falls Risk Assessment Tool (PJC-FRAT), a multidisciplinary falls risk screening and intervention deployment instrument. Methods: In phase 1, the accuracy of the PJC-FRAT was prospectively compared to a gold standard (the STRATIFY) on a cohort of subacute hospital patients (n = 122). In phase 2, the PJC-FRAT was temporally reassessed using a subsequent cohort (n = 316), with results compared to those of phase 1. Primary outcomes were falls (events), fallers (patients who fell), and hospital completion rates of the PJC-FRAT. Results: In phase 1, PJC-FRAT accuracy of identifying falters showed sensitivity of 73% (bootstrap 95% confidence interval CI = 55, 90) and specificity of 75% (95% CI = 66, 83), compared with the STRATIFY (cutoff >= 2/5) sensitivity of 77% (95% CI = 59, 92) and specificity of 51% (95% CI = 41, 61). This difference was not significant. In phase 2, accuracy of nursing staff using the PJC-FRAT was lower. PJC-FRAT completion rates varied among disciplines over both phases: nurses and physiotherapists, >= 90%; occupational therapists, >= 82%; and medical officers, >= 57%. Conclusion: The PJC-FRAT was practical and relatively accurate as a predictor of falls and a deployment instrument for falls prevention interventions, although continued staff education may be necessary to maintain its accuracy. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe the development of a capture enzyme-linked immunosorbent assay for the detection of the dengue virus nonstructural protein NS1. The assay employs rabbit polyclonal and monoclonal antibodies as the capture and detection antibodies, respectively. Immunoaffinity-purified NS1 derived from dengue 2 virus-infected cells was used as a standard to establish a detection sensitivity of approximately 4 ng/ml for an assay employing monoclonal antibodies recognizing a dengue 2 serotype-specific epitope. A number of serotype cross-reactive monoclonal antibodies were also shown to be suitable probes for the detection of NS1 expressed by the remaining three dengue virus serotypes. Examination of clinical samples demonstrated that the assay was able to detect NS1 with minimal interference from serum components at the test dilutions routinely used, suggesting that it could form the basis of a useful additional diagnostic test for dengue virus infection. Furthermore, quantitation of NS1 levels in patient sera may prove to be a valuable surrogate marker for viremia. Surprisingly high levels of NS1, as much as 15 mu g/ml, were found in acute-phase sera taken hom some of the patients experiencing serologically confirmed dengue 2 virus secondary infections but was not detected in the convalescent sera of these patients. In contrast, NS1 could not be detected in either acute-phase or convalescent serum samples taken from patients with serologically confirmed primary infection. The presence of high levels of secreted NS1 in the sera of patients experiencing secondary dengue virus infections, and in the context of an anamnestic antibody response, suggests that NS1 may contribute significantly to the formation of the circulating immune complexes that are suspected to play an important role in the pathogenesis of severe dengue disease.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Primary objectives: (1) To investigate the Nonword Repetition test (NWR) as an index of sub-vocal rehearsal deficits after mild traumatic brain injury (mTBI); (2) to assess the reliability, validity and sensitivity of the NWR; and (3) to compare the NWR to more sensitive tests of verbal memory. Research design: An independent groups design. Methods and procedures: Study 1 administered the NWR to 46 mTBI and 61 uninjured controls with the Rapid Screen of Concussion (RSC). Study 2 compared mTBI, orthopaedic and uninjured participants on the NWR and the Hopkins Verbal Learning Test (HVLT-R). Main outcomes and results: The NWR did not improve the diagnostic accuracy of the RSC. However, it is reliable and indexes sub-vocal rehearsal speed. These findings provide evidence that although the current form of the NWR lacks sensitivity to the impact of mTBI, the development of a more sensitive test of sub-vocal rehearsal deficits following mTBI is warranted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study aimed to determine whether including a sensitive test of immediate and delayed recall would improve the diagnostic validity of the Rapid Screen of Concussion (RSC) in mild Traumatic Brain Injury (mTBI) versus orthopaedic clinical samples. Two studies were undertaken. In Study 1, the performance of 156 mTBI and 145 orthopaedic participants was analysed to identify the number of individuals who performed at ceiling on the verbal memory subtest of the RSC, as this test required immediate and delayed recall of only five words. A second aim was to determine the sensitivity and specificity levels of the RSC. Study 2 aimed to examine whether replacement of the verbal memory subtest with the 12-word Hopkins Verbal Learning Test (HVLT) could improve the sensitivity of the RSC in a new sample of 26 mTBI and 30 orthopaedic participants. Both studies showed that orthopaedic participants outperformed mTBI participants on each of the selected measures. Study 1 showed that 14% of mTBI participants performed at ceiling on the immediate and 21.2% on delayed recall test. Performance on the original battery yielded a sensitivity of 82%, specificity of 80% and overall correct classification of 81.5% participants. In Study 2, inclusion of the HVLT improved sensitivity to a level of 88.5%, decreased specificity to a level of 70% and resulted in an overall classification rate of 80%. It was concluded that although inclusion of the five-word subtest in the RSC can successfully distinguish concussed from non-concussed individuals, use of the HVLT in this protocol yields a more sensitive measure of subtle cognitive deficits following mTBI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: This paper describes SeqDoC, a simple, web-based tool to carry out direct comparison of ABI sequence chromatograms. This allows the rapid identification of single nucleotide polymorphisms (SNPs) and point mutations without the need to install or learn more complicated analysis software. Results: SeqDoC produces a subtracted trace showing differences between a reference and test chromatogram, and is optimised to emphasise those characteristic of single base changes. It automatically aligns sequences, and produces straightforward graphical output. The use of direct comparison of the sequence chromatograms means that artefacts introduced by automatic base-calling software are avoided. Homozygous and heterozygous substitutions and insertion/deletion events are all readily identified. SeqDoC successfully highlights nucleotide changes missed by the Staden package 'tracediff' program. Conclusion: SeqDoC is ideal for small-scale SNP identification, for identification of changes in random mutagenesis screens, and for verification of PCR amplification fidelity. Differences are highlighted, not interpreted, allowing the investigator to make the ultimate decision on the nature of the change.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Test-retest reliabilities and practice affects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice affects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.