2 resultados para physiological measurements
em University of Queensland eSpace - Australia
Resumo:
Achievement of steady state during indirect calorimetry measurements of resting energy expenditure (REE) is necessary to reduce error and ensure accuracy in the measurement. Steady state is often defined as 5 consecutive min (5-min SS) during which oxygen consumption and carbon dioxide production vary by +/-10%. These criteria, however, are stringent and often difficult to satisfy. This study aimed to assess whether reducing the time period for steady state (4-min SS or 3-min SS) produced measurements of REE that were significantly different from 5-min SS. REE was measured with the use of open-circuit indirect calorimetry in 39 subjects, of whom only 21 (54%) met the 5-min SS criteria. In these 21 subjects, median biases in REE between 5-min SS and 4-min SS and between 5-min SS and 3-min SS were 0.1 and 0.01%, respectively. For individuals, 4-min SS measured REE within a clinically acceptable range of +/-2% of 5-min SS, whereas 3-min SS measured REE within a range of -2-3% of 5-min SS. Harris-Benedict prediction equations estimated REE for individuals within +/-20-30% of 5-min SS. Reducing the time period of steady state to 4 min produced measurements of REE for individuals that were within clinically acceptable, predetermined limits. The limits of agreement for 3-min SS fell outside the predefined limits of +/-2%; however, both 4-min SS and 3-min SS criteria greatly increased the proportion of subjects who satisfied steady state within smaller limits than would be achieved if relying on prediction equations.
Resumo:
Objective This study aims to understand the pathophysiology of anaphylaxis in Dirofflaria immitis-sensitised cats by analysing objective physiological and haematological measurements after challenge. Design Nineteen healthy D immitis-naive cats were sensitised using weekly injections of aluminium hydroxide-adjuvanted D immitis antigen, administered subcutaneously over 6 weeks. After sensitisation, cats (n = 16) were anaesthetised and challenged with intravenous D immitis antigen. A control group (n = 3) was sham-challenged using intravenous sterile 0.9% saline. Systolic blood pressure (measured non-invasively/indirectly), respiratory rate, degree of dyspnoea, blood 0, saturation, expired CO2, and heart rate and were measured immediately before and at 10 to 15 min intervals after challenge until terminal apnoea occurred or euthanasia at 140 mins post-challenge. Blood was collected for complete blood count immediately before and at 10, 20 and 35 mins after challenge. Clinical observations were recorded as they occurred. Results Antigen-challenged cats were divided into two groups: acute (apnoea occurred within 25 mins of challenge) and subacute (breathing at 25 mins after challenge). In both groups, the degree of dyspnoea increased and blood O-2 saturation and blood pressure decreased. Respiratory rate increased in the subacute group. Expired CO2 decreased in both Ag-challenged and control groups. Haematocrit increased in the subacute group. Neutrophil count decreased in the acute group and platelet count decreased in the subacute group. Eosinophil count decreased in the subacute and control groups. Sustained dyspnoea and gastrointestinal signs were the most common clinical manifestations of anaphylaxis in the antigen-challenged cats. Conclusions Intravenous challenge with D immitis antigen in sensitised cats results in dyspnoea, hypoxaemia and systemic hypotension accompanied by haemoconcentration.