30 resultados para phase-contrast imaging

em University of Queensland eSpace - Australia


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES We sought to determine whether the transmural extent of scar (TES) explains discordances between dobutamine echocardiography (DbE) and thallium single-photon emission computed tomography (Tl-SPECT) in the detection of viable myocardium (VM). BACKGROUND Discrepancies between DbE and Tl-SPECT are often attributed to differences between contractile reserve and membrane integrity, but may also reflect a disproportionate influence of nontransmural scar on thickening at DbE. METHODS Sixty patients (age 62 +/- 12 years; 10 women and 50 men) with postinfarction left ventricular dysfunction underwent standard rest-late redistribution Tl-SPECT and DbE. Viable myocardium was identified when dysfunctional segments showed Tl activity >60% on the late-redistribution image or by low-dose augmentation at DbE. Contrast-enhanced magnetic resonance imaging (ceMRI) was used to divide TES into five groups: 0%, 75% of the wall thickness replaced by scar. RESULTS As TES increased, both the mean Tl uptake and change in wall motion score decreased significantly (both p < 0.001). However, the presence of subendocardial scar was insufficient to prevent thickening; >50% of segments still showed contractile function with TES of 25% to 75%, although residual function was uncommon with TES >75%. The relationship of both tests to increasing TES was similar, but Tl-SPECT identified VM more frequently than DbE in all groups. Among segments without scar or with small amounts of scar (50% were viable by SPECT. CONCLUSIONS Both contractile reserve and perfusion are sensitive to the extent of scar. However, contractile reserve may be impaired in the face of no or minor scar, and thickening may still occur with extensive scar. (C) 2004 by the American College of Cardiology Foundation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contrast enhanced magnetic resonance imaging (CE MRI) is the most sensitive tool for screening women who are at high familial risk of breast cancer. Our aim in this study was to assess the cost-effectiveness of X-ray mammography (XRM), CE MRI or both strategies combined. In total, 649 women were enrolled in the MARIBS study and screened with both CE MRI and mammography resulting in 1881 screens and 1-7 individual annual screening events. Women aged 35-49 years at high risk of breast cancer, either because they have a strong family history of breast cancer or are tested carriers of a BRCA1, BRCA2 or TP53 mutation or are at a 50% risk of having inherited such a mutation, were recruited from 22 centres and offered annual MRI and XRM for between 2 and 7 years. Information on the number and type of further investigations was collected and specifically calculated unit costs were used to calculate the incremental cost per cancer detected. The numbers of cancer detected was 13 for mammography, 27 for CE MRI and 33 for mammography and CE MRI combined. In the subgroup of BRCA1 (BRCA2) mutation carriers or of women having a first degree relative with a mutation in BRCA1 (BRCA2) corresponding numbers were 3 (6), 12 (7) and 12 (11), respectively. For all women, the incremental cost per cancer detected with CE MRI and mammography combined was 28 pound 284 compared to mammography. When only BRCA1 or the BRCA2 groups were considered, this cost would be reduced to 11 pound 731 (CE MRI vs mammography) and 15 pound 302 (CE MRI and mammography vs mammography). Results were most sensitive to the unit cost estimate for a CE MRI screening test. Contrast-enhanced MRI might be a cost-effective screening modality for women at high risk, particularly for the BRCA1 and BRCA2 subgroups. Further work is needed to assess the impact of screening on mortality and health-related quality of life.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two-dimensional (2-D) strain (epsilon(2-D)) on the basis of speckle tracking is a new technique for strain measurement. This study sought to validate epsilon(2-D) and tissue velocity imaging (TVI)based strain (epsilon(TVI)) with tagged harmonic-phase (HARP) magnetic resonance imaging (MRI). Thirty patients (mean age. 62 +/- 11 years) with known or suspected ischemic heart disease were evaluated. Wall motion (wall motion score index 1.55 +/- 0.46) was assessed by an expert observer. Three apical images were obtained for longitudinal strain (16 segments) and 3 short-axis images for radial and circumferential strain (18 segments). Radial epsilon(TVI) was obtained in the posterior wall. HARP MRI was used to measure principal strain, expressed as maximal length change in each direction. Values for epsilon(2-D), epsilon(TVI), and HARP MRI were comparable for all 3 strain directions and were reduced in dysfunctional segments. The mean difference and correlation between longitudinal epsilon(2-D) and HARP MRI (2.1 +/- 5.5%, r = 0.51, p < 0.001) were similar to those between longitudinal epsilon(TVI), and HARP MRI (1.1 +/- 6.7%, r = 0.40, p < 0.001). The mean difference and correlation were more favorable between radial epsilon(2-D) and HARP MRI (0.4 +/- 10.2%, r = 0.60, p < 0.001) than between radial epsilon(TVI), and HARP MRI (3.4 +/- 10.5%, r = 0.47, p < 0.001). For circumferential strain, the mean difference and correlation between epsilon(2-D) and HARP MRI were 0.7 +/- 5.4% and r = 0.51 (p < 0.001), respectively. In conclusion, the modest correlations of echocardiographic and HARP MRI strain reflect the technical challenges of the 2 techniques. Nonetheless, epsilon(2-D) provides a reliable tool to quantify regional function, with radial measurements being more accurate and feasible than with TVI. Unlike epsilon(TVI), epsilon(2-D) provides circumferential measurements. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To use quantitative myocardial contrast echocardiography (MCE) and strain rate imaging (SRI) to assess the role of microvascular disease in subclinical diabetic cardiomyopathy. Methods: Stress MCE and SRI were performed in 48 patients (22 with type II diabetes mellitus (DM) and 26 controls), all with normal left ventricular systolic function and no obstructive coronary disease by quantitative coronary angiography. Real-time MCE was acquired in three apical views at rest and after combined dipyridamole-exercise stress. Myocardial blood flow (MBF) was quantified in the 10 mid- and apical cardiac segments at rest and after stress. Resting peak systolic strain rate (SR) and peak systolic strain (epsilon) were calculated in the same 10 myocardial segments. Results: The DM and control groups were matched for age, sex and other risk factors, including hypertension. The DM group had higher body mass index and left ventricular mass index. Quantitative SRI analysis was possible in all patients and quantitative MCE in 46 (96%). The mean e, SR and MBF reserve were all significantly lower in the DM group than in controls, with diabetes the only independent predictor of each parameter. No correlation was seen between MBF and SR (r = -0.01, p = 0.54) or between MBF and epsilon ( r = -0.20, p = 0.20). Conclusions: Quantitative MCE shows that patients with diabetes but no evidence of obstructive coronary artery disease have impaired MBF reserve, but abnormal transmural flow and subclinical longitudinal myocardial dysfunction are not related.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background-Although assessment of myocardial perfusion by myocardial contrast echocardiography (MCE) is feasible, its incremental benefit to stress echocardiography is not well defined. We examined whether the addition of MCE to combined dipyridamole-exercise echocardiography (DExE) provides incremental benefit for evaluation of coronary artery disease (CAD). Methods and Results-MCE was combined with DExE in 85 patients, 70 of whom were undergoing quantitative coronary angiography and 15 patients with a low probability of CAD. MCE was acquired by low-mechanical-index imaging in 3 apical views after acquisition of standard resting and poststress images. Wall motion, left ventricular opacification, and MCE components of the study were interpreted sequentially, blinded to other data. Significant (>50%) stenoses were present in 43 patients and involved 69 coronary territories. The addition of qualitative MCE improved sensitivity for the detection of CAD (91% versus 74%, P=0.02) and accurate recognition of disease extent (87% versus 65% of territories, P=0.003), with a nonsignificant reduction in specificity. Conclusions-The addition of low-mechanical-index MCE to standard imaging during DExE improves detection of CAD and enables a more accurate determination of disease extent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical evaluation of arterial potency in acute ST-elevation myocardial infarction (STEMI) is unreliable. We sought to identify infarction and predict infarct-related artery potency measured by the Thrombolysis In Myocardial Infarction (TIMI) score with qualitative and quantitative intravenous myocardial contrast echocardiography (MCE). Thirty-four patients with suspected STEMI underwent MCE before emergency angiography and planned angioplasty. MCE was performed with harmonic imaging and variable triggering intervals during intravenous administration of Optison. Myocardial perfusion was quantified offline, fitting an exponential function to contrast intensity at various pulsing intervals. Plateau myocardial contrast intensity (A), rate of rise (beta), and myocardial flow (Q = A x beta) were assessed in 6 segments. Qualitative assessment of perfusion defects was sensitive for the diagnosis of infarction (sensitivity 93%) and did not differ between anterior and inferior infarctions. However, qualitative assessment had only moderate specificity (50%), and perfusion defects were unrelated to TIMI flow. In patients with STEMI, quantitatively derived myocardial blood flow Q (A x beta) was significantly lower in territories subtended by an artery with impaired (TIMI 0 to 2) flow than those territories supplied by a reperfused artery with TIMI 3 flow (10.2 +/- 9.1 vs 44.3 +/- 50.4, p = 0.03). Quantitative flow was also lower in segments with impaired flow in the subtending artery compared with normal patients with TIMI 3 flow (42.8 +/- 36.6, p = 0.006) and all segments with TIMI 3 flow (35.3 +/- 32.9, p = 0.018). An receiver-operator characteristic curve derived cut-off Q value of

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.