42 resultados para operational parameters
em University of Queensland eSpace - Australia
Resumo:
Objective-The purpose of mammographic screening is to reduce mortality from breast cancer. This study describes a method for projecting the number of screens to be performed by a mammographic screening programme, and applies this method in the context of New South Wales, Australia. Method-The total number of mammographic screens was projected as the sum of initial screens and re-screens, and is based on projections of the population, rates of new recruitment, rates of attrition within the programme, and the mix of screening intervals. The baseline scenario involved: 70% participation of women aged 50-69 years, 90% return rate for the second and subsequent re-screens, 5% annual screens (95% biennial screens), and a specified population projection. The results were assessed with respect to variations in these assumptions. Results-The projections were strongly influenced by: the rate of screening of the target age group; the proportion of women re-screened annually; and the rates of attrition within the programme. Although demographic change had a notable effect, there was little difference between different population projections. Standard assumptions about attrition within the programme suggest that the current target participation rates in NSW may not be achieved in the long term. Conclusions-A practical model for projecting mammographic screens for populations is described which is capable of forecasting the number of screens under different scenarios. Implications-Projections of mammographic screens provide important information for the planning and financing of equipment and personnel, and for testing the effects of variations in important operational parameters. Re-screening attrition is an important contributor to screening viability.
Resumo:
In electronic support, receivers must maintain surveillance over the very wide portion of the electromagnetic spectrum in which threat emitters operate. A common approach is to use a receiver with a relatively narrow bandwidth that sweeps its centre frequency over the threat bandwidth to search for emitters. The sequence and timing of changes in the centre frequency constitute a search strategy. The search can be expedited, if there is intelligence about the operational parameters of the emitters that are likely to be found. However, it can happen that the intelligence is deficient, untrustworthy or absent. In this case, what is the best search strategy to use? A random search strategy based on a continuous-time Markov chain (CTMC) is proposed. When the search is conducted for emitters with a periodic scan, it is shown that there is an optimal configuration for the CTMC. It is optimal in the sense that the expected time to intercept an emitter approaches linearity most quickly with respect to the emitter's scan period. A fast and smooth approach to linearity is important, as other strategies can exhibit considerable and abrupt variations in the intercept time as a function of scan period. In theory and numerical examples, the optimum CTMC strategy is compared with other strategies to demonstrate its superior properties.
Resumo:
Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, nonlinear curve fitting. An alternative fitting method is described that uses only the magnitude of the measured impedances at four selected frequencies. The two methods showed excellent agreement when compared using data obtained both from measurements of equivalent circuits and of humans. These results suggest that operational equivalence to a technically complex, frequency-scanning, phase-sensitive BIS analyser could be achieved from a simple four-frequency, impedance-only analyser.
Resumo:
Purpose: The relationship between six descriptors of lactate increase, peak (V) over dot O-2,W-peak, and 1-h cycling performance were compared in 24 trained, female cyclists (peak (V) over dot O-2 = 48.11 +/- 6.32 mL . kg(-1) . min(-1)). Methods: The six descriptors of lactate increase were: 1) lactate threshold (LT; the power output at which plasma lactate concentration begins to increase above the resting level during an incremental exercise test), 2) LT1 (the power output at which plasma lactate increases by 1 mM or more), 3) LTD (the lactate threshold calculated by the D-max method), 4) LTMOD (the lactate threshold calculated by a modified D-max method), 5) L4 (the power output at which plasma lactate reaches a concentration of 4 mmol-L-1), and 6) LTLOG (the power output at which plasma lactate concentration begins to increase when the log([La-]) is plotted against the log (power output)). Subjects first completed a peak (V) over dot O-2 test on a cycle ergometer. Finger-tip capillary blood was sampled within 30 s of the end of each 3-min stage for analysis of plasma lactate. Endurance performance was assessed 7 d later using a 1-h cycle test (OHT) in which subjects were directed to achieve the highest possible average power output. Results: The mean power output (W) for the OHT (+/- SD) was 183.01 +/- 18.88, and for each lactate variable was: LT (138.54 +/- 46.61), LT1 (179.17 +/- 27.25), LTLOG (143.97 +/- 45.74), L4 (198.09 +/- 33.84), LTD (178.79 +/- 24.07), LTMOD (212.28 +/- 31.75). Average power output during the OHT was more strongly correlated with all plasma lactate parameters (0.61 < r < 0.84) and W-peak (r = 0.81) than with peak (V) over dot O-2 (r = 0.55). The six lactate parameters were strongly correlated with each other (0.54 < r < 0.91) and of the six lactate parameters, LTD correlated best with endurance performance (r = 0.84). Conclusions: It was concluded that plasma lactate parameters and W-peak provide better indices of endurance performance than peak (V) over dot O-2 and that, of the six descriptors of lactate increase measured in this study, LTD is most strongly related to 1-h cycling performance in trained, female cyclists.
Resumo:
We consider two different kinds of fluctuations in an ion trap potential: external fluctuating electrical fields, which cause statistical movement (wobbling) of the ion relative to the center of the trap, and fluctuations of the spring constant, which an due to fluctuations of the ac component of the potential applied in the Paul trap for ions. We write down master equations for both cases and, averaging out the noise, obtain expressions for the heating of the ion. We compare our results to previous results for far-off resonance optical traps and heating in ion traps. The effect of fluctuating external electrical fields for a quantum gate operation (controlled-NOT) is determined and the fidelity for that operation derived. [S1050-2947(99)06005-9].
Resumo:
CXTANNEAL is a program for analysing contaminant transport in soils. The code, written in Fortran 77, is a modified version of CXTFIT, a commonly used package for estimating solute transport parameters in soils. The improvement of the present code is that it includes simulated annealing as the optimization technique for curve fitting. Tests with hypothetical data show that CXTANNEAL performs better than the original code in searching for optimal parameter estimates. To reduce the computational time, a parallel version of CXTANNEAL (CXTANNEAL_P) was also developed. (C) 1999 Elsevier Science Ltd. All rights reserved.
Resumo:
The artificial chaperone method for protein refolding developed by Rozema et al. (Rozema, D.; Gellman, S. H. J. Am. Chem. Soc. 1995, 117 (8), 2373-2374) involves the sequential dilution of denatured protein into a buffer containing detergent (cetyltrimethylammonium bromide, CTAB) and then into a refolding buffer containing cyclodextrin WD). In this paper a simplified one-step artificial chaperone method is reported, whereby CTAB is added directly to the denatured solution, which is then diluted directly into a refolding buffer containing P-cyclodextrin (P-CD). This new method can be applied at high protein concentrations, resulting in smaller processing volumes and a more concentrated protein solution following refolding. The increase in achievable protein concentration results from the enhanced solubility of CTAB at elevated temperatures in concentrated denaturant. The refolding yields obtained for the new method were significantly higher than for control experiments lacking additives and were comparable to the yields obtained with the classical two-step approach. A study of the effect of beta-CD and CTAB concentrations on refolding yield suggested two operational regimes: slow stripping ( beta-CDXTABsimilar to1), most suited for higher protein concentrations, and fast stripping (beta-CD/CTABsimilar to2.7), best suited for lower protein concentrations. An increased chaotrope concentration resulted in higher refolding yields and an enlarged operational regime.
Resumo:
Pulse wave velocity (PWV) is a known parameter that is related to arterial distensibility. However, its potential is hampered by the absence of appropriate techniques to estimate it noninvasively. PWV can be used as an assessment of increased arterial stiffness that is linked to systolic hypertension, excess cardiovascular morbidity and mortality.(1,2)