278 resultados para mitral valve disease

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An entire female English bull terrier, aged five years and one month, was diagnosed with polycystic kidney disease by renal ultrasonography. It had thickening and abnormal motion of the mitral valve on 2D and M mode echocardiography, and left ventricular outflow tract obstruction, characterised by turbulence in the left ventricular outflow tract and elevated aortic blood flow velocity, detected by colour flow and spectral Doppler echocardiography, respectively. Two years later, haematology, serum biochemistry and urinalysis data suggested the presence of compensated renal failure. The dog was euthanased at 10 years and eight months of age, with haematology, serum biochemistry and urinalysis data indicating decompensated chronic renal failure. Postmortem examination confirmed polycystic kidney disease, chronic renal disease, mitral and aortic valvular myxomatous degeneration, and mixed mammary neoplasia. This case demonstrates that bull terriers with polycystic kidney disease may develop associated chronic renal failure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Control recommendations are presented for four genetic or familial diseases that cause significant morbidity and mortality in affected English Bull Terriers. Bull Terrier polycystic kidney disease is an autosomal dominant disease diagnosed by detecting a minimum of three renal cysts, with cysts present in both kidneys, and similarly affected family members to confirm the inherited nature of the cysts. Bull Terrier hereditary nephritis is an autosomal dominant disease diagnosed in otherwise normal animals with urinary protein: creatinine ratios persistently >0.3 and no significant urinary sediment, a family history of the disease, and characteristic glomerular basement membrane lesions. Mitral valve myxomatous degeneration and left ventricular outflow tract obstruction in Bull Terriers are familial diseases diagnosed by auscultating characteristic murmurs in affected animals. Excluding animals with these clinical signs from the breeding pool will reduce the prevalence rates of these diseases, however maintenance of an effective population size is also important. Providing breeders with information on genetics, including the risks associated with inbreeding and the benefits of outcrossing, is likely to improve canine breeding practices, thus increasing fitness and fecundity of these purebred dogs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The first derivative of pressure over time (dP/dt) is a marker of left ventricular (LV) systolic function that can be assessed during cardiac catheterization and echocardiography. Radial artery dP/dt (Radial-dP/dt) has been proposed as a possible marker of LV systolic function (Nichols & O’Rourke, McDonald’s Blood Flow in Arteries) and we sought to test this hypothesis. Methods:We compared simultaneously recorded RadialdP/ dt (by high-fidelity tonometry) with LV-dP/dt (by highfidelity catheter and echocardiography parameters analogous to LV-dP/dt) in patients without aortic valve disease. In study 1, beat to beat Radial-dP/dt and LV-dP/dt were recorded at rest and during supine exercise in 12 males (aged 61±12 years) undergoing cardiac catheterization. In study 2, 2D-echocardiography and Radial-dP/dt were recorded in 59 patients (43 men; aged 64±10 years) at baseline and peak dobutamine-induced stress. Three measures at the basal septum were taken as being analogous to LV-dP/dt: (1) peak systolic strain rate, (2) strain rate (SR-dP/dt), and (3) tissue velocity during isovolumic contraction. Results: Study 1; there was a significant difference between resting LV-dP/dt (1461±383 mmHg/s) and Radial-dP/dt (1182±319 mmHg/s; P < 0.001), and a poor, but statistically significant, correlation between the variables (R2 = 0.006; P < 0.001) due to the high number of data points compared (n = 681). Similar results were observed during exercise. Study 2; there was a moderate association between baseline Radial-dP/dt and SRdP/ dt (R2 =−0.17; P < 0.01), but no significant relationship between Radial-dP/dt and all other echocardiographic measures analogous to LV-dP/dt at rest or peak stress (P > 0.05). Conclusion: The radial pressurewaveform is not a reliable marker of LV contractility.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Latent left ventricular (LV) dysfunction in patients with valvular or myocardial disease may be identified by loss of contractile reserve (CR) at exercise echocardiography. Contraction in the LV longitudinal axis may be more sensitive than radial contraction to minor disturbances of LV function. We sought to determine whether tissue Doppler measurement of longitudinal function could be used to identify CR. Methods Exercise echocardiography was performed in 86 patients (20 women, age 53 +/- 18 years), 72 with asymptomatic or minimally symptomatic mitral regurgitation, and 14 normal controls. Pulsed-wave tissue Doppler imaging (DTI) was used to measure maximum annular systolic velocity at rest and stress. Inducible ischemia was excluded by analysis of wall motion by an experienced observer. CR was defined by greater than or equal to5% improvement of stress compared with rest ejection fraction (EF). Exercise capacity was assessed from expired gas analysis. Results CR was present in 34 patients with mitral regurgitation (47%); peak EF in patients with and without CR was 74% +/- 11% versus 54% +/- 15% (P

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate contractile reserve (CR) determined by exercise echocardiography in predicting clinical outcome and left ventricular (LV) function in asymptomatic severe mitral regurgitation (MR). Design: Cohort study. Setting: Regional cardiac centre. Patients and outcome measures: LV volumes and ejection fraction (EF) were measured at rest and after stress in 71 patients with isolated MR. During follow up (mean (SD) 3 (1) years), EF and functional capacity were serially assessed and cardiac events ( cardiac death, heart failure, and new atrial fibrillation) were documented. Results: CR was present in 45 patients (CR+) and absent in 26 patients (CR-). Age, resting LV dimensions, EF, and MR severity were similar in both groups. Mitral surgery was performed in 19 of 45 (42%) CR+ patients and 22 of 26 (85%) CR2 patients. In patients undergoing surgery, CR was an independent predictor of follow up EF (p = 0.006) and postoperative LV dysfunction (EF < 50%) persisted in five patients, all in the CR2 group. Event-free survival was lower in surgically treated patients without CR (p = 0.03). In medically treated patients, follow up EF was preserved in those with intact CR but progressively deteriorated in patients without CR, in whom functional capacity also deteriorated. Conclusions: Evaluation of CR by exercise echocardiography may be useful for risk stratification and may help to optimise the timing of surgery in asymptomatic severe MR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background - Marfan syndrome (MS) is a genetic disorder caused by a mutation in the fibrillin gene FBN1. Bicuspid aortic valve (BAV) is a congenital heart malformation of unknown cause. Both conditions are associated with ascending aortic aneurysm and premature death. This study examined the relationship among the secretion of extracellular matrix proteins fibrillin, fibronectin, tenascin, and vascular smooth muscle cell (VSMC) apoptosis. The role of matrix metalloproteinase (MMP)- 2 in VSMC apoptosis was studied in MS aneurysm. Methods and Results - Aneurysm tissue was obtained from patients undergoing surgery ( MS: 4 M, 1 F, age 27 - 45 years; BAV: 3 M, 2 F, age 28 - 65 years). Normal aorta from subjects with nonaneurysm disease was also collected ( 4 M, 1 F, age 23 - 93 years). MS and BAV aneurysm histology showed areas of cystic medial necrosis (CMN) without inflammatory infiltrate. Immunohistochemical study of cultured MS and BAV VSMC showed intracellular accumulation and reduction of extracellular distribution of fibrillin, fibronectin, and tenascin. Western blot showed no increase in expression of fibrillin, fibronectin, or tenascin in MS or BAV VSMC and increased expression of MMP-2 in MS VSMCs. There was 4-fold increase in loss of cultured VSMC incubated in serum-free medium for 24 hours in both MS ( 27 +/- 8%) and BAV ( 32 +/- 14%) compared with control ( 7 +/- 5%). Conclusions - In MS and BAV there is alteration in both the amount and quality of secreted proteins and an increased degree of VSMC apoptosis. Up-regulation of MMP-2 might play a role in VSMC apoptosis in MS VSMC. The findings suggest the presence of a fundamental cellular abnormality in BAV thoracic aorta, possibly of genetic origin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. Design Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. Procedure All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. Results These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the maximising method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific normal left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. Conclusion These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Mitral repair is increasingly performed in asymptomatic mitral regurgitation (MR). Previous work showed that pre-operative documentation of loss of contractile reserve (Cr) by exercise echo (ExE) may predict LV dysfunction early after repair. We sought the value of Cr in predicting late post-op LV dysfunction and clinical outcome. Methods: Pre-op ExE was performed in 41 pts with isolated MR without coronary disease undergoing repair. LV end-systolic and end-diastolic volumes were measured at rest and post-stress and EF was calculated using modified Simpson’s rule. Intact Cr was defined by >4% increment of stress compared with rest EF. During follow up (3±1 years), EF was serially assessed and occurrence of cardiac events was documented. Results: Cr was present in 19 pts (Cr+)(peak EF 76±7%) and absent in 22 pts (Cr-)(peak EF 56±11%, p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is now considerable evidence to suggest that non-demented people with Parkinson's disease (PD) experience difficulties using the morphosyntactic aspects of language. It remains unclear, however, at precisely which point in the processing of morphosyntax, these difficulties emerge. The major objective of the present study was to examine the impact of PD on the processes involved in accessing morphosyntactic information in the lexicon. Nineteen people with PD and 19 matched control subjects participated in the study which employed on-line word recognition tasks to examine morphosyntactic priming for local grammatical dependencies that occur both within (e.g. is going) and across (e.g. she gives) phrasal boundaries (Experiments 1 and 2, respectively). The control group evidenced robust morphosyntactic priming effects that were consistent with the involvement of both pre- (Experiment 1) and post-lexical (Experiment 2) processing routines. Whilst the participants with PD also recorded priming for dependencies within phrasal boundaries (Experiment 1), priming effects were observed over an abnormally brief time course. Further, in contrast to the controls, the PD group failed to record morphosyntactic priming for constructions that crossed phrasal boundaries (Experiment 2). The results demonstrate that attentionally mediated mechanisms operating at both the pre- and post-lexical stages of processing are able to contribute to morphosyntactic priming effects. In addition, the findings support the notion that, whilst people with PD are able to access morphosyntactic information in a normal manner, the time frame in which this information remains available for processing is altered. Deficits may also be experienced at the post-lexical integrational stage of processing.