9 resultados para microparticles

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet-derived microparticles that are produced during platelet activation are capable of adhesion and aggregation. Endothelial trauma that occurs during percutaneous transluminal coronary angioplasty (PTCA) may support platelet-derived microparticle adhesion and contribute to development of restenosis. We have previously reported an increase in platelet-derived microparticles in peripheral arterial blood with angioplasty. This finding raised concerns regarding the role of platelet-derived microparticles in restenosis, and therefore the aim of this study was to monitor levels in the coronary circulation. The study population consisted of 19 angioplasty patients. Paired coronary artery and sinus samples were obtained following heparinization, following contrast administration, and subsequent to all vessel manipulation. Platelet-derived microparticles were identified with an anti-CD61 (glycoprotein IIIa) fluorescence-conjugated antibody using flow cytometry. There was a significant decrease in arterial platelet-derived microparticles from heparinization to contrast administration (P=0.001), followed by a significant increase to the end of angioplasty (P=0.004). However, there was no significant change throughout the venous samples. These results indicate that the higher level of platelet-derived microparticles after angioplasty in arterial blood remained in the coronary circulation. Interestingly, levels of thrombin-antithrombin complexes did not rise during PTCA. This may have implications for the development of coronary restenosis post-PTCA, although this remains to be determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A review with 93 references. Heparins are high molecular weight, hydrophilic polyanions, which are unstable under acidic conditions; and therefore they exhibit poor oral bioavailability. Consequently they must be administered via the parenteral route which is expensive, inconvenient, and limits use by outpatients. The development of an oral form of heparin is warranted. This review examined the literature, mostly published between January 2000 and January 2005, pertaining to the gastrointestinal absorption of heparin by lipidization or coadministration with penetration enhancers. A lipidization strategy that was examined involved conjugation of low molecular weight heparin with deoxycholic acid. The majority of studies examined the ability of different formulations, typically utilizing penetration enhancers, to improve heparin bioavailability. The penetration enhancers used included fatty acids, Labrasol™, Gelucire 44/14™, polycationic lipophilic-core dendrons, saponins, mono-N-carboxymethyl chitosan, Carbopol® 934P, a combination of thiolated polycarbophil and glutathione, polymeric nanoparticles, polymeric microparticles, sodium N-[8-(2-hydroxybenzoyl) amino]caprylate (SNAC), and sodium N-[10-(2-hydroxybenzoyl)amino]decanoate (SNAD). The variety of models used and doses of heparin/penetration enhancers applied, however, made it difficult to compare the results between studies. Nevertheless, all of the reviewed drug delivery systems showed therapeutic value and confirmation of the promising results obtained from animal studies, by progression to clinical trials, is necessary. Overall, progress has been made in the quest for an oral heparin formulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microencapsulation of cell spheroids in an immunoselective, highly biocompatible, biomembrane offers a way to create viable implantation options in the treatment of insulin-dependent diabetes mellitus (IDDM). Traditionally the encapsulation process has been achieved through the injection/extrusion of alginate/cell mixtures into a calcium chloride solution to produce calcium alginate capsules around the cells. A novel alternative is explored here through a procedure using an emulsion process to produce thin adherent calcium alginate membranes around cell spheroids. In this study, a thorough investigation has been used to establish the emulsion process parameters that are critical to the formation of a coherent alginate coat both on a model spheroid system and subsequently on cell spheroids. Optical and fluorescence microscopy are used to assess the morphology and coherence of the calcium alginate/ poly-L-ornithine/alginate (APA) capsules produced. (c) 2005 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability to control the surface properties and subsequent colloidal stability of dispersed particles has widespread applicability in many fields. Sub-micrometer fluorescent silica particles (reporters) can be used to actively encode the combinatorial synthesis of peptide libraries through interparticle association. To achieve these associations, the surface chemistry of the small fluorescent silica reporters is tailored to encourage robust adhesion to large silica microparticles onto which the peptides are synthesized. The interparticle association must withstand a harsh solvent environment multiple synthetic and washing procedures, and biological screening buffers. The encoded support beads were exposed to different solvents used for peptide synthesis, and different solutions used for biological screening including phosphate buffered saline (PBS), 2-[N-morpholino]ethane sulfonic acid (VIES) and a mixture of MES and N-(3-dimethyl-aminopropyl)-N'-ethylcarbodiimide (EDC). The number of reporters remaining adhered to the support bead was quantified after each step. The nature of the associations were explored and tested to optimize the efficiency of these phenomena. Results presented illustrate the influence of the surface functionality and polyelectrolyte modification of the reporters. These parameters were investigated through zeta potential and X-ray photoelectron spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the gas-particle dynamics of a device designed for biological pre-clinical experiments. The device uses transonic/supersonic gas flow to accelerate microparticles such that they penetrate the outer skin layers. By using a shock tube coupled to a correctly expanded nozzle, a quasi-one-dimensional, quasi-steady flow (QSF) is produced to uniformly accelerate the microparticles. The system utilises a microparticle cassette (a diaphragm sealed container) that incorporates a jet mixing mechanism to stir the particles prior to diaphragm rupture. Pressure measurements reveal that a QSF exit period - suitable for uniformly accelerating microparticles - exists between 155 and 220 mus after diaphragm rupture. Immediately preceding the QSF period, a starting process secondary shock was shown to form with its (x,t) trajectory comparing well to theoretical estimates. To characterise the microparticle, flow particle image velocimetry experiments were conducted at the nozzle exit, using particle payloads with varying diameter (2.7-48 mu m), density (600-16,800 kg/m(3)) and mass (0.25-10 mg). The resultant microparticle velocities were temporally uniform. The experiments also show that the starting process does not significantly influence the microparticle nozzle exit velocities. The velocity distribution across the nozzle exit was also uniform for the majority of microparticle types tested. For payload masses typically used in pre-clinical drug and vaccine applications (

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Biolistic injections provide a needle-free delivery of antigen-laden microparticles to the epithelium. The precision of the injection preferentially targets the Langerhans cell network, which, although ideal for vaccination, might not be suitable for the downregulation of immune responses in immunotherapy. Objective: We sought to determine the ability of biolistic injection of antigen into the epithelium of sensitized mice to inhibit IgE antibody and lung inflammatory responses produced by further exposure to antigen. Methods: Mice were sensitized by means of a needle injection of ovalbumin (OVA) in alum and given a series of biolistic injections of OVA or vehicle control, followed by a boost of OVA in alum. Serum IgE and IgG antibodies were measured before and after the boost. The mice were then challenged intranasally, and the infiltration of inflammatory cells was measured by means of bronchoalveolar lavage. Airway reactivity of the challenged mice was measured by examining responses to methacholine with forced oscillatory techniques. Results: Biolistic injection of OVA into the dorsal skin of sensitized mice markedly inhibited IgE and IgG1 antibody responses induced by boosting. IgG2a antibody responses were reduced rather than stimulated. The eosinophilic inflammation in the bronchoalveolar lavage fluid induced by intranasal challenge was also markedly inhibited. Lung hyperreactivity showed an initial increase and then a decrease of responsiveness to methacholine, with elastance returning to the level of unsensitized mice. Biolistic injection into the buccal epithelium was also inhibitory. Conclusions: Biolistic injection of allergen inhibited the boosting of IgE antibody and eosinophilic lung inflammatory responses without inducing TO immunity.