3 resultados para microclimate.

em University of Queensland eSpace - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selective laser sintering has been used to fabricate an aluminium alloy powder preform which is subsequently debound and infiltrated with a second aluminium alloy. This represents a new rapid manufacturing system for aluminium that can be used to fabricate large, intricate parts. The base powder is an alloy such as AA6061. The infiltrant is a binary or higher-order eutectic based on either Al-Cu or At-Si. To ensure that infiltration occurs without loss of dimensional precision, it is important that a rigid skeleton forms prior to infiltration. This can be achieved by the partial transformation of the aluminium to aluminium nitride. In order for this to occur throughout the component, magnesium powder must be added to the alumina support powder which surrounds the part in the furnace. The magnesium scavenges the oxygen and thereby creates a microclimate in which aluminium nitride can form. The replacement of the ionocovalent Al2O3 with the covalent AlN on the surface of the aluminium powders also facilitates wetting and thus spontaneous and complete infiltration. (C) 2004 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eighteen Angus steers exposed to high heat load conditions were used to assess the effectiveness of four spray cooling systems, on reducing the effects of heat load, the impact on microclimate and water usage. The steers were housed in groups of nine in a fully enclosed shed and were exposed to high heat load conditions for four days. The cooling systems used were water applied via a hose, via overhead sprinklers, via sprinklers at leg height and via misters. The water used was approximately 31 oC and contained 3% NaCl. Fans were used to ensure adequate air movement over the cattle. The animal parameters measured were feed intake, respiration rate, panting score and behaviour. Climatic factors were ambient temperature and wet bulb temperature. Ammonia levels were also measured. The hose, overhead sprinklers and misting were successful in reducing heat load on the cattle. The leg wetting system did not work because the dominant cattle blocked access to the sprinklers. The misting system used the most water (5483 L) and the hose the least (845 L). The application of water had minor impacts on wet bulb temperature, but resulted in significant reductions in dry bulb temperatures.