186 resultados para measurement scale
em University of Queensland eSpace - Australia
Resumo:
In addition to a gene with major effect, minor genes were found to contribute to the genetic regulation of foliar resistance to Ascochyta blight in two crosses between two resistant and one susceptible lentil cultivars (lines). This was established by comparing inbred lines with and without the major resistance gene. The effects of minor genes were not large enough to change the phenotypic performance determined by its major gene qualitatively (from resistant to susceptible, or vice versa) based on the measurement scale used. However, they did substantially and significantly modify the resistance level. The major gene for foliar resistance was linked to the gene(s) for seed infection rate and/or had a positive pleiotrophic effect on seed infection rate. Similarly, the major gene for foliar resistance was linked to the gene(s) for seed yield/plant in disease free environments and/or had negative pleiotrophic effects on yield/plant. Selection for resistance and yield among inbreds with the same major resistance gene may be necessary to enhance the resistance level, and to reduce the negative effect on yield of the major resistance gene.
Resumo:
Objective: To examine the performance of the Norwegian version of the AUSCAN Index as a disease-specific health status measure in patients with hand osteoarthritis (OA). Methods: One hundred and ninety-nine patients with clinical hand OA (mean (SD) age 61.7 (5.7) years, 18 (9%) males) underwent a comprehensive examination including joint status, examination of grip strength and completion of several self-reported health status questionnaires. The Australian/Canadian OA hand index (AUSCAN) captures three different dimensions of hand OA: pain (5 items), stiffness (1 item), and difficulties with daily activities (9 items). Our pre-study hypothesis was to identify AUSCAN as a specific hand measure with strong correlations to hand measures and lower correlations to other general measures of health. Results: Patient completion of the AUSCAN Index was similar or better than other measures. The internal consistency of the AUSCAN was excellent. The pain and physical dimension of AUSCAN correlated substantially to, each other and moderately to the stiffness scale. The AUSCAN physical scale correlated moderately to substantially to other measures, the highest correlation being seen with the Arthritis Impact Measurement Scale (AIMS) 2 hand and finger function scale (r= 0.73). The standardised differences between patients with and without radiographic abnormalities were numerically larger for the AUSCAN pain and physical scales than for other measures. Conclusion: The Norwegian version of the AUSCAN has an acceptable clinimetric performance and is a suitable tool for assessment of hand OA. (C) 2005 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study determined the inter-tester and intra-tester reliability of physiotherapists measuring functional motor ability of traumatic brain injury clients using the Clinical Outcomes Variable Scale (COVS). To test inter-tester reliability, 14 physiotherapists scored the ability of 16 videotaped patients to execute the items that comprise the COVS. Intra-tester reliability was determined by four physiotherapists repeating their assessments after one week, and three months later. The intra-class correlation coefficients (ICC) were very high for both inter-tester reliability (ICC > 0.97 for total COVS scores, ICC > 0.93 for individual COVS items) and intra-tester reliability (ICC > 0.97). This study demonstrates that physiotherapists are reliable in the administration of the COVS.
Resumo:
The Flow State Scale-2 (FSS-2) and Dispositional Flow Scale-2 (DFS-2) are presented as two self-report instruments designed to assess flow experiences in physical activity. Item modifications were made to the original versions of these scales in order to improve the measurement of some of the flow dimensions. Confirmatory factor analyses of an item identification and a cross-validation sample demonstrated a good fit of the new scales. There was support for both a 9-first-order factor model and a higher order model with a global flow factor. The item identification sample yielded mean item loadings on the first-order factor of .78 for the FSS-2 and .77 for the DFS-2. Reliability estimates ranged from .80 to .90 for the FSS-2, and .81 to .90 for the DFS-2. In the cross-validation sample, mean item loadings on the first-order factor were .80 for the FSS-2, and .73 for the DFS-2. Reliability estimates ranged between .80 to .92 for the FSS-2 and .78 to .86 for the DFS-2. The scales are presented as ways of assessing flow experienced within a particular event (FSS-2) or the frequency of flow experiences in chosen physical activity in general (DFS-2).
Resumo:
A measure of dimensional anxiety specifically designed for use in older people is urgently needed. Such a measure could be used in a variety of settings to screen for anxiety disorders and to measure response to treatment in older people with established anxiety disorders. We have developed a new instrument to measure generalized anxiety symptoms in older people, the Geriatric Anxiety Inventory (GAI). This new instrument uses plain language, minimises somatic items and has a dichotomous response scale. Although it is a self-report measure, it may readily be administered to frail and mildly cognitively impaired older people by nursing staff. The development and initial validation of the GAI will be described. The scale was administered to community samples as well as patients with anxiety, depression, and mild cognitive impairment. Reliability was high and validity sound when compared to a range of standard anxiety instruments, and the instrument was well-tolerated among these cohorts. Sensitivity, specificity and cut-off scores for community and impatient samples will be presented.
Resumo:
Research on outcomes from psychiatric disorders has highlighted the importance of expressed emotion (EE), but its cost-effective measurement remains a challenge. This article describes development of the Family Attitude Scale (FAS), a 30-item instrument that can be completed by any informant. Its psychometric characteristics are reported in parents of undergraduate students and in 70 families with a schizophrenic member. The total FAS had high internal consistency in all samples, and reports of angry behaviour in FAS items showed acceptable inter-rater agreement. The FAS was associated with the reported anger, anger expression and anxiety of respondents. Substantial associations between the parents' FAS and the anger and anger expression of students was also observed. Parents of schizophrenic patients had higher FAS scores than parents of students, and the FAS was higher if disorder duration was longer or patient functioning was poorer. Hostility, high criticism and low warmth on the Camberwell Family Interview (CFI) were associated with a more negative FAS. The highest FAS in the family was a good predictor of a highly critical environment on the CFI. The FAS is a reliable and valid indicator of relationship stress and expressed anger that has wide applicability. (C) 1997 Elsevier Science Ireland Ltd.
Resumo:
We describe the conditional and unconditional dynamics of two coupled quantum dots when one dot is subjected to a measurement of its occupation number by coupling it to a third readout dot via the Coulomb interaction. The readout dot is coupled to source and drain leads under weak bias, and a tunnel current flows through a single bound state when energetically allowed. The occupation of the quantum dot near the readout dot shifts the bound state of the readout dot from a low conducting state to a high conducting state. The measurement is made by continuously monitoring the tunnel current through the readout dot. We show that there is a difference between the time scale for the measurement-induced decoherence between the localized states of the dots, and the time scale on which the system becomes localized due to the measurement.
Resumo:
This paper reports on the motor and functional outcomes of 20 children with developmental coordination disorder (DCD) aged 4-8 years consecutively referred to a pediatric physiotherapy service. Children with a Movement ABC (M-ABC) score less than the 15th percentile, and with no concurrent medical, sensory, physical, intellectual or neurological impairments, were recruited. The Motor Assessment Outcomes Model (MAOM) [Coster and Haley, Infants and Young Children 4 (1992) 11] provided the theoretical base for measurement selection, and preliminary findings at the activities and participation levels of the model are reported in this article. Children with DCD performed at the lower end of the normal range on the Pea-body Developmental Motor Scales (fine motor total score) (M = 85.65, SD = 12.23). Performance on the Visual Motor Integration Test (VMI) standard scores was within the average range (M = 96.15, SD = 10.69). Videotaped observations of the children's writing and cutting indicated that 29% were left-handed and that a large proportion of all children (31%) utilized unusual pencil grasp patterns and immature prehension of scissors. Measurement at the participation level involved use of the Pictorial Scale of Perceived Competence and Social Acceptance (PCSA) and Pediatric Evaluation of Disability Inventory (PEDI). Overall, these young children rated themselves towards the more competent and accepted end of the PCSA over the dimensions of physical and cognitive competence and peer and maternal acceptance. The PEDI revealed generally average performance on social (M = 49.98, SD = 16.62) and mobility function (M = 54.71, SD = 3.99), however, self-care function was below the average range for age (M = 38.01, SD = 12.19). The utility of the MAOM as a framework for comprehensive measurement of functional and motor outcomes of DCD in young children is discussed. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.
Resumo:
Participation in at least 30 min of moderate intensity activity on most days is assumed to confer health benefits. This study accordingly determined whether the more vigorous household and garden tasks (sweeping, window cleaning, vacuuming and lawn mowing) are performed by middle-aged men at a moderate intensity of 3-6 metabolic equivalents (METs) in the laboratory and at home. Measured energy expenditure during self-perceived moderate-paced walking was used as a marker of exercise intensity. Energy expenditure was also predicted via indirect methods. Thirty-six males [Xmacr (SD): 40.0 (3.3) years; 179.5 (6.9) cm; 83.4 (14.0) kg] were measured for resting metabolic rate (RMR) and oxygen consumption (V.O-2) during the five activities using the Douglas bag method. Heart rate , respiratory frequency, CSA (Computer Science Applications) movement counts, Borg scale ratings of perceived exertion and Quetelet's index were also recorded as potential predictors of exercise intensity. Except for vacuuming in the laboratory, which was not significantly different from 3.0 METs (P=0.98), the MET means in the laboratory and home were all significantly greater than 3.0 (Pless than or equal to0.006). The sweeping and vacuuming MET means were significantly higher (P
Resumo:
Objective. To assess the measurement properties of a simple index of symptom severity in osteoarthritis (OA) of the hips and knees. Methods. Both the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the proposed new Comprehensive Osteoarthritis Test (COAT) instrument were completed weekly by 125 subjects in the context of a randomized, 12-week, 3 parallel-arm clinical trial. The reliabilities of the various scales were assessed on a weekly basis by use of Cronbach's alpha coefficients. The validity of the COAT total scale was assessed by correlation with the WOMAC total scale on a weekly basis with correlation coefficients, and in terms of the correlations between subject-level intercepts and slopes over time. The relative responsiveness of the WOMAC and COAT total scales was assessed using a multilevel (longitudinal) multivariate (WOMAC, COAT) linear model. Results. The WOMAC and COAT total scales were highly reliable (mean over weeks: WOMAC alpha = 0.98; COAT alpha = 0.97). The correlations between the WOMAC and COAT scales were very high (mean over weeks = 0.92; subject-level intercepts = 0.91, slopes = 0.88). The COAT total scale was significantly more responsive than the WOMAC total scale in the active treatment (34.8% improvement vs 26.8%; p = 0.002). Conclusion. The COAT total scale is simple to administer, reliable, valid, and responsive to treatment effects.
Resumo:
The measurement of alcohol craving began with single-item scales. Multifactorial scales developed with the intention to capture more fully the phenomenon of craving. This study examines the construct validity of a multifactorial scale, the Yale-Brown Obsessive Compulsive Scale for heavy drinking (Y-BOCS-hd). The study compares its clinical utility with a single item visual-analogue craving scale. The study includes 212 alcohol dependent subjects (127 males, 75 females) undertaking an outpatient treatment program between 1999-2001. Subjects completed the Y-BOCS-hd and a single item visual-analogue scale, in addition to alcohol consumption and dependence severity measures. The Y-BOCS-hd had strong construct validity. Both the visual-analogue alcohol craving scale and Y-BOCS-hd were weakly associated with pretreatment dependence severity. There was a significant association between pretreatment alcohol consumption and the visual-analogue craving scale. Neither craving measure was able to predict total program abstinence or days abstinent. The relationship between obsessive-compulsive behavior in alcohol dependence and craving remains unclear.
Resumo:
Background: The effective evaluation of physical activity interventions for older adults requires measurement instruments with acceptable psychometric properties that are sufficiently sensitive to detect changes in this population. Aim: To assess the measurement properties (reliability and validity) of the Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire in a sample of older Australians. Methods: CHAMPS data were collected from 167 older adults (mean age 79.1 S.D. 6.3 years) and validated with tests of physical ability and the SF-12 measures of physical and mental health. Responses from a sub-sample of 43 older adults were used to assess 1-week test-retest reliability. Results: Approximately 25% of participants needed assistance to complete the CHAMPS questionnaire. There were low but significant correlations between the CHAMPS scores and the physical performance measures (rho=0.14-0.32) and the physical health scale of the SF-12 (rho=0.12-0.24). Reliability coefficients were highest for moderate-intensity (ICC=0.81-0.88) and lowest for vigorous-intensity physical activity (ICC=0.34-0.45). Agreement between test-retest estimates of sufficient physical activity for health benefits (>= 150 min and >= 5 sessions per week) was high (percent agreement = 88% and Cohen's kappa = 0.68). Conclusion: These findings suggest that the CHAMPS questionnaire has acceptable measurement properties, and is therefore suitable for use among older Australian adults, as long as adequate assistance is provided during administration. (c) 2006 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.