96 resultados para intra-laboratory testing
em University of Queensland eSpace - Australia
Resumo:
The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55–70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and 1 laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R= .66), lower body strength (sit to stand, R= .80) and functional capacity (Canadian Step Test, R= .92), but not for leg power (single timed chair rise, R= .28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r= .68, p< .05), and for the step test (cf PWC140, r= −.60, p< .001), but not for the lift and reach (cf 1RM bench press, r= .43, p> .05), balance (r= −.13, −.18, .23) and rate of force development tests (r= −.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.
Resumo:
Background: Syphilis remains a significant cause of preventable perinatal death in developing countries with many women remaining untested and thus untreated. Syphilis testing in the clinic (on-site testing) may be a useful strategy to overcome this. We studied the impact of on-site syphilis testing on treatment delays and rates, and perinatal mortality. Methods: We conducted a cluster randomised controlled trial among seven pairs of primary healthcare clinics in rural South Africa, comparing on-site testing complemented by laboratory confirmation versus laboratory testing alone. Intervention clinics used the on-site test conducted by primary care nurses, with results and treatment available within an hour. Control clinics sent blood samples to the provincial laboratory, with results returned 2 weeks later. Results: Of 7134 women seeking antenatal care with available test results, 793 (11.1%) tested positive for syphilis. Women at intervention clinics completed treatment 16 days sooner on average (95% confidence interval: 11 to 21), though there was no significant difference in the proportion receiving adequate treatment at intervention (64%) and control (69%) clinics. There was also no significant difference in the proportion experiencing perinatal loss (3.3% v 5.1%; adjusted risk difference: -0.9%; 95% Cl -4.4 to 2.7). Conclusions: Despite reducing treatment delays, the addition of on-site syphilis testing to existing laboratory testing services did not lead to higher treatment rates or reduce perinatal mortality. However on-site testing for syphilis may remain an important option for improving antenatal care in settings where laboratory facilities are not available.
Resumo:
We have designed and tested an Internet-based video-phone suitable for use in the homes of families in need of paediatric palliative care services. The equipment uses an ordinary telephone line and includes a PC, Web camera and modem housed in a custom-made box. In initial field testing, six clinical consultations were conducted in a one-month trial of the videophone with a family in receipt of palliative care services who were living in the outer suburbs of Brisbane. Problems with variability in call quality-namely audio and video freezing, and audio break-up-prompted further laboratory testing. We completed a programme of over 250 test calls. Fixing modem connection parameters to use the V.34 modulation protocol at a set bandwidth of 24 kbit/s improved connection stability and the reliability of the video-phone. In subsequent field testing 47 of 50 calls (94%) connected without problems. The freezes that did occur were brief (with greatly reduced packet loss) and had little effect on the ability to communicate, unlike the problems arising in the home testing. The low-bandwidth Internet-based video-phone we have developed provides a feasible means of doing telemedicine in the home.
Resumo:
This review aims to provide a foundation for the safe and effective use of magnesium (Mg) alloys, including practical guidelines for the service use of Mg alloys in the atmosphere and/or in contact with aqueous solutions. This is to provide support for the rapidly increasing use of Mg in industrial applications, particularly in the automobile industry. These guidelines should be firmly based on a critical analysis of our knowledge of SCC based on (1) service experience, (2) laboratory testing and (3) understanding of the mechanism of SCC, as well as based on an understanding of the Mg corrosion mechanism.
Resumo:
In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. Standardized calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 mug cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 mug cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intra-laboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required. (C) 2005 Wiley-Liss, Inc.
Resumo:
The efficiency of numerous mineral processing operations can be determined by measuring the magnetic properties of the process streams. This measurement, if done at all, is currently performed by laboratory testing of spot samples. This is an inherently slow process and, where feed grades are variable, optimum performance is generally not achieved. This paper describes the rapid measurement of the magnetic properties of minerals. AC measurement techniques, including the analysis of the phase component of the magnetic vector; frequency dependent magnetic susceptibility and the effect of applied magnetic field strength will be discussed. Industrial applications in mineral sands, copper smelting, ferrosilicon testing and drill core scanning will be reported. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
A dry sand-rubber wheel abrasion test was used to investigate the wear behaviour of polyurethanes. The dry sand-rubber wheel abrasion test (DSRW test) is an approved ASTM test designed primarily for testing metals, therefore, in this study the set of test conditions was optimized for use with polyurethane elastomers. The wear performance of polyurethanes was assessed for the range of Shore hardness 85A to 65D, and a correlation was identified between the wear rate and the sample hardness. Polyurethane elastomers can be separated into three classes according to their hardness and wear performance, and each class shows a different dependence on the specimen temperature. This work has implications for use of the DSRW test for the prediction of field performance of polyurethanes. (C) Elsevier Science S.A.
Resumo:
Computational models complement laboratory experimentation for efficient identification of MHC-binding peptides and T-cell epitopes. Methods for prediction of MHC-binding peptides include binding motifs, quantitative matrices, artificial neural networks, hidden Markov models, and molecular modelling. Models derived by these methods have been successfully used for prediction of T-cell epitopes in cancer, autoimmunity, infectious disease, and allergy. For maximum benefit, the use of computer models must be treated as experiments analogous to standard laboratory procedures and performed according to strict standards. This requires careful selection of data for model building, and adequate testing and validation. A range of web-based databases and MHC-binding prediction programs are available. Although some available prediction programs for particular MHC alleles have reasonable accuracy, there is no guarantee that all models produce good quality predictions. In this article, we present and discuss a framework for modelling, testing, and applications of computational methods used in predictions of T-cell epitopes. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
A simple technique for routine, reproducible global surveillance of the drug susceptibility status of the anaerobic protozoa Trichomonas, Entamoeba, and Giardia is described, Data collected using this technique can be readily compared among different laboratories and with previously reported data. The technique employs a commercially available sachet and bag system to generate a low-oxygen environment and log, drug dilutions in microtiter plates, which can be monitored without aerobic exposure, to assay drug-resistant laboratory lines and clinically resistant isolates. MICs (after 2 days) of 3.2 and 25 muM indicated metronidazole-sensitive and highly clinically resistant isolates of T. vaginalis in anaerobic assays, respectively. The aerobic MICs were 25 and > 200 muM. MICs (1 day) of 12.5 to 25 muM were found for axenic lines of E. histolytica, and MICs for G. duodenalis (3 days) ranged from 6.3 muM for metronidazole-sensitive isolates to 50 muM for laboratory metronidazole-resistant lines. This technique should encourage more extensive monitoring of drug resistance in these organisms.
Resumo:
This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues. (C) 2062 Elsevier Science B.V. All rights reserved.
Resumo:
Despite widespread awareness that children with Down syndrome are particularly susceptible to hearing pathologies, the audiological status of students with Down syndrome in special schools is all too often unknown. Unfortunately, hearing screening for this population is unable to rely on standard, behavioural test batteries. To facilitate future improvements in screening protocols, this study investigated the results of tympanometry and transient evoked otoacoustic emission (TEOAE) testing for a group of children with Down syndrome. Assessments were not conducted in the artificial context of a clinic or laboratory, but within the school environment. Outcomes are reported for 27 subjects with a mean age of 10 years 5 months (SD = 4;11). Tympanometry testing was failed in at least one ear by 41.7% of subjects, while a failure rate of 81.5% of subjects was observed for TEOAE testing. Therefore, it is concluded that immediate review of hearing screening programs for students with Down syndrome is highly advisable.
Resumo:
Background: Observation of the occurrence of protective muscle activity is advocated in assessment of the peripheral nervous system by means of neural provocation tests. However, no studies have yet demonstrated abnormal force generation in a patient population. Objectives: To analyze whether aberrations in shoulder girdle-elevation force during neural tissue provocation testing for the median nerve (NTPTI) can be demonstrated, and whether possible aberrations can be normalized following cervical mobilization. Study Design: A single-blind randomized comparative controlled study. Setting: Laboratory setting annex in a manual therapy teaching practice. Participants: Twenty patients with unilateral or bilateral neurogenic cervicobrachial pain. Methods: During the NTPTI, we used a load cell and electrogoniometer to record continuously the shoulder-girdle elevation force in relation to the available range of elbow extension. Following randomization, we analyzed the immediate treatment effects of a cervical contralateral lateral glide mobilization technique (experimental group) and therapeutic ultrasound (control group). Results: On the involved side, the shoulder-girdle elevation force occur-red earlier, and the amount of force at the end of the test was substantially, though not significantly, greater than that on the uninvolved side at the corresponding range of motion. Together with a significant reduction in pain perception after cervical mobilization, a clear tendency toward normalization of the force curve could be observed, namely, a significant decrease in force generation and a delayed onset. The control group demonstrated no differences. Conclusions: Aberrations in force generation during neural, provocation testing are present in patients with neurogenic pain and can be normalized with appropriate treatment modalities.
Resumo:
A 12-year-old male castrated Samoyed dog was presented with left-sided epistaxis and sneezing. Diagnostic procedures included haematology and biochemistry testing, thoracic radiography, fine needle aspiration of regional lymph nodes, CT, rhinoscopy, incisional biopsy and histopathology. Squamous cell carcinoma of the rostral nasal cavity was diagnosed, with no evidence of metastatic disease. External beam radiation was not an accessible treatment option. Complete surgical resection of the tumour would have required a larger, more disfiguring resection of nasal planum and maxilla than the owner was prepared to accept and may have been associated with an unacceptable morbidity. As an alternative, the extent of disease was reduced using a combination of carboplatin, doxorubicin and piroxicam chemotherapy. This allowed a less extensive nasal planum removal to be performed to remove residual disease with clean margins. The patient achieved a 14 month disease free interval from the time of surgery to the time of local recurrence. Survival time from diagnosis to eventual euthanasia for progressive local disease was 18 months.