2 resultados para in-situ test

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the existence of global modes and local modes of the neighbouring members, damage detection on a structure is more challenging than damage on isolated beams. Detection of an artificial circumferential crack on a joint in a frame-like welded structure is studied in this paper using coupled response measurements. Similarity to real engineering structures is maintained in the fabrication of the test frame. Both the chords and the branch members have hollow sections and the branch members have smaller sizes. The crack is created by a hacksaw on a joint where a branch meets the chord. The methodology is first demonstrated on a single hollow section beam. The test results are then presented for the damaged and undamaged frame. The existence of the damage is clearly observable from the experimental results. It is suggested that this approach offers the-potential to detect damage in welded structures such as cranes, mining equipment, steel-frame bridges, naval and offshore structures. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: The objective of this study was to evaluate the accuracy, ease of use and reproducibility of chromogenic in situ hybridisation (CISH) for HER2 testing by studying its inter-laboratory concordance in five Australian pathology laboratories. Methods: The HER2 status of 49 breast cancers was determined by CISH twice in two different laboratories. Each sample had previously been tested by immunohistochemistry (IHC; 2+ and 3+ cases selected) and fluorescence in situ hybridisation ( FISH). Participating laboratories were blinded to these test results. Oestrogen receptor ( ER) status was also evaluated for each cancer. Results: High correlation was observed between FISH and CISH results. No cases showing high gene amplification by FISH were scored as non-amplified by CISH ( kappa coefficient=1). High correlation was observed between IHC and CISH, all IHC 3+ samples showing amplification by CISH. Inter-laboratory CISH concordance was also good ( kappa coefficient=0.67). Fifty-six per cent of HER2-amplified samples tested ER positive, while 42% of ER-positive cases showed HER2 gene amplification, confirming that HER2 testing should not be confined to ER-negative breast cancers. Conclusions: These findings demonstrate that CISH is a robust test to assess HER2 status in breast cancer and therefore is an important addition to the HER2 testing algorithm.