12 resultados para heat load index

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To investigate the extent of heat load problems, caused by the combination of excessive temperature and humidity, in Holstein-Friesian cows in Australia. Also, to outline how milk production losses and consequent costs from this can be estimated and minimised. Procedures Long-term meteorological data for Australia were analysed to determine the distribution of hot conditions over space and time. Fifteen dairy production regions were identified for higher-resolution data analysis. Both the raw meteorological data and their integration into a temperature-humidity thermal index were compiled onto a computer program. This mapping software displays the distribution of climatic patterns, both Australia-wide and within the selected dairying regions. Graphical displays of the variation in historical records for 200 locations in the 15 dairying regions are also available. As a separate study, production data from research stations, on-farm trials and milk factory records were statistically analysed and correlated with the climatic indices, to estimate production losses due to hot conditions. Results Both milk yields and milk constituents declined with increases in the temperature-humidity index. The onset and rate of this decline are dependent on a number of factors, including location, level of production, adaptation, and management regime. These results have been integrated into a farm-level economic analysis for managers of dairy properties. Conclusion By considering the historical patterns of hot conditions over time and space, along with expected production losses, managers of dairy farms can now conduct an economic evaluation of investment strategies to alleviate heat loads. These strategies include the provision of sprinklers, shade structures, or combinations of these.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: This study investigated leukocyte subset responses to moderate-intensity exercise under heat stress, with water (W) or carbohydrate (CHO) drink ingestion. Methods: In repeated trials, 13 soldiers consumed either a W or CHO drink during 3 h of walking at 4.4 km center dot h(-1) with a 5% gradient (15 min rest per hour) under heat stress (35 C and 55% relative humidity). The soldiers wore combat uniforms and carried water bottles and dummy rifles and ammunition, altogether weighing about 11.5 +/- 1.0 kg. Results: Plasma glucose concentration was significantly higher with CHO than W ingestion during exercise (p < 0.01). There were no significant differences between W and CHO conditions in exercise performance, plasma cortisol concentration, heart rate, or core temperature. CHO ingestion significantly moderated the increases in leukocyte (83% in W, 28% in CHO; p < 0.001), monocyte (60% in W, 34% in CHO; p < 0.05), and granulocyte counts (120% in W, 30% in CHO; p < 0.001), but not in lymphocyte count (41% in W, 25% in CHO). Conclusions: The increases in leukocyte and subset counts during moderate-intensity exercise under heat stress may be comparable to those observed during intense exercise in cool conditions. The response of immune cell counts is blunted by CHO intake during moderate-intensity exercise in the heat, and may not occur through the cortisol pathway.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Eighteen Angus steers exposed to high heat load conditions were used to assess the effectiveness of four spray cooling systems, on reducing the effects of heat load, the impact on microclimate and water usage. The steers were housed in groups of nine in a fully enclosed shed and were exposed to high heat load conditions for four days. The cooling systems used were water applied via a hose, via overhead sprinklers, via sprinklers at leg height and via misters. The water used was approximately 31 oC and contained 3% NaCl. Fans were used to ensure adequate air movement over the cattle. The animal parameters measured were feed intake, respiration rate, panting score and behaviour. Climatic factors were ambient temperature and wet bulb temperature. Ammonia levels were also measured. The hose, overhead sprinklers and misting were successful in reducing heat load on the cattle. The leg wetting system did not work because the dominant cattle blocked access to the sprinklers. The misting system used the most water (5483 L) and the hose the least (845 L). The application of water had minor impacts on wet bulb temperature, but resulted in significant reductions in dry bulb temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Disease is the result of interactions amongst pathogens, the environment and host organisms. To investigate the effect of stress on Penaeus monodon, juvenile shrimp were given short term exposure to hypoxic, hyperthermic and osmotic stress twice over a 1-week period and estimates of total haemocyte count (THC), heat shock protein (HSP) 70 expression and load of gill associated virus (GAV) were determined at different time points. While no significant differences were observed in survival and THC between stressed and control shrimp (P>0.05), HSP 70 expression and GAV load changed significantly (P