16 resultados para extrahepatic portal venous obstruction

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance cholangiography (MRC) relies on the strong T-2 signal from stationary liquids, in this case bile, to generate images. No contrast agents are required, and the failure rate and risk of serious complications is lower than with endoscopic retrograde cholangiopancreatography (ERCP). Data from MRC can be summated to produce an image much like the cholangiogram obtained by using ERCP. In addition, MRC and conventional MRI can provide information about the biliary and other anatomy above and below a biliary obstruction. This provides information for therapeutic intervention that is probably most useful for hilar and intrahepatic biliary obstruction. Magnetic resonance cholangiography appears to be similar to ERCP with respect to sensitivity and specificity in detecting lesions causing biliary obstruction, and in the diagnosis of choledocholithiasis. It is also suited to the assessment of biliary anatomy (including the assessment of surgical bile-duct injuries) and intrahepatic biliary pathology. However, ERCP can be therapeutic as well as diagnostic, and MRC should be limited to situations where intervention is unlikely, where intrahepatic or hilar pathology is suspected, to delineate the biliary anatomy prior to other interventions, or after failed or inadequate ERCP. Magnetic resonance angiography (MRA) relies on the properties of flowing liquids to generate images. It is particularly suited to assessment of the hepatic vasculature and appears as good as conventional angiography. It has been shown to be useful in delineating vascular anatomy prior to liver transplantation or insertion of a transjugular intrahepatic portasystemic shunt. Magnetic resonance angiography may also be useful in predicting subsequent variceal haemorrhage in patients with oesophageal varices. (C) 2000 Blackwell Science Asia Pty Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Today, the standard approach for the kinetic analysis of dynamic PET studies is compartment models, in which the tracer and its metabolites are confined to a few well-mixed compartments. We examine whether the standard model is suitable for modern PET data or whether theories including more physiologic realism can advance the interpretation of dynamic PET data. A more detailed microvascular theory is developed for intravascular tracers in single-capillary and multiple-capillary systems. The microvascular models, which account for concentration gradients in capillaries, are validated and compared with the standard model in a pig liver study. Methods: Eight pigs underwent a 5-min dynamic PET study after O-15-carbon monoxide inhalation. Throughout each experiment, hepatic arterial blood and portal venous blood were sampled, and flow was measured with transit-time flow meters. The hepatic dual-inlet concentration was calculated as the flow-weighted inlet concentration. Dynamic PET data were analyzed with a traditional single-compartment model and 2 microvascular models. Results: Microvascular models provided a better fit of the tissue activity of an intravascular tracer than did the compartment model. In particular, the early dynamic phase after a tracer bolus injection was much improved. The regional hepatic blood flow estimates provided by the microvascular models (1.3 +/- 0.3 mL min(-1) mL(-1) for the single-capillary model and 1.14 +/- 0.14 min(-1) mL(-1) for the multiple-capillary model) (mean +/- SEM mL of blood min(-1) mL of liver tissue(-1)) were in agreement with the total blood flow measured by flow meters and normalized to liver weight (1.03 +/- 0.12 mL min(-1) mL(-1)). Conclusion: Compared with the standard compartment model, the 2 microvascular models provide a superior description of tissue activity after an intravascular tracer bolus injection. The microvascular models include only parameters with a clear-cut physiologic interpretation and are applicable to capillary beds in any organ. In this study, the microvascular models were validated for the liver and provided quantitative regional flow estimates in agreement with flow measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modeling physiological processes using tracer kinetic methods requires knowledge of the time course of the tracer concentration in blood supplying the organ. For liver studies, however, inaccessibility of the portal vein makes direct measurement of the hepatic dual-input function impossible in humans. We want to develop a method to predict the portal venous time-activity curve from measurements of an arterial time-activity curve. An impulse-response function based on a continuous distribution of washout constants is developed and validated for the gut. Experiments with simultaneous blood sampling in aorta and portal vein were made in 13 anesthetized pigs following inhalation of intravascular [O-15] CO or injections of diffusible 3-O[ C-11] methylglucose (MG). The parameters of the impulse-response function have a physiological interpretation in terms of the distribution of washout constants and are mathematically equivalent to the mean transit time ( T) and standard deviation of transit times. The results include estimates of mean transit times from the aorta to the portal vein in pigs: (T) over bar = 0.35 +/- 0.05 min for CO and 1.7 +/- 0.1 min for MG. The prediction of the portal venous time-activity curve benefits from constraining the regression fits by parameters estimated independently. This is strong evidence for the physiological relevance of the impulse-response function, which includes asymptotically, and thereby justifies kinetically, a useful and simple power law. Similarity between our parameter estimates in pigs and parameter estimates in normal humans suggests that the proposed model can be adapted for use in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1 The hepatic disposition and metabolite kinetics of a homologous series of O-acyl (acetyl, propionyl, butanoyl, pentanoyl, hexanoyl and octanoyl) esters of salicylic acid (C2SA, C3SA, C4SA, C5SA, C6SA and C8SA, respectively) was determined using a single-pass, in-sills rat liver preparation. 2 The hepatic venous outflow profiles for the parent esters and the generated metabolite, salicylic acid (SA) were analysed by HPLC. Non-parametric moments analysis was used to determine the area under the curve (AUC'), mean transit time (MTT) and normalized variance (CV2) for the parent esters and generated SA. 3 Pregenerated SA ([C-14]-salicylic acid) was injected into each liver with the parent ester to determine its distribution characteristics. 4 The overall recovery of ester plus metabolite was 89% of the ester dose injected and independent of the ester carbon number, suggesting that ester extraction was due to hepatic metabolism to salicylic acid. 5 The metabolite AUC' value increased directly with the lipophilicity of the parent ester (from 0.12 for C2SA to 0.95 for C8SA). By contrast, the parent AUC' decreased with the lipophilicity (from 0.85 for C2SA to zero for C8SA). The metabolite MTT value also showed a trend to increase with the lipophilicity of the parent ester (from 15.72 s for C3SA to 61.97 s for C8SA). However, the parent MTT value shows no significant change across the series. 6 The two-compartment dispersion model was used to derive the kinetic parameters for parent ester, pregenerated SA and generated SA. Consequently, these parameters were used to estimate the values of AUG', MITT and CV2 for the parent ester and metabolite. The moments values obtained using the two-compartment dispersion model show similar trends to the corresponding moments values obtained from the outflow profiles using a non-parametric approach. 7 The more lipophilic aspirin analogues are more confined to the portal circulation after oral administration than aspirin due to their more extensive hepatic elimination avoiding systemic prostacyclin inhibition. Given that aspirin's selectivity as an anti-thrombotic agent has been postulated to be due to selective anti-platelet effects in the portal circulation, the more lipophilic and highly extracted analogues are potentially more selective anti-thrombotic agents than aspirin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hepatic disposition and metabolite kinetics of a homologous series of diflunisal O-acyl esters (acetyl, butanoyl, pentanoyl, anti hexanoyl) were determined using a single-pass perfused in situ rat liver preparation. The experiments were conducted using 2% BSA Krebs-Henseleit buffer (pH 7.4), and perfusions were performed at 30 mL/min in each liver. O-Acyl esters of diflunisal and pregenerated diflunisal were injected separately into the portal vein. The venous outflow samples containing the esters and metabolite diflunisal were analyzed by high performance liquid chromatography (HPLC). The normalized outflow concentration-time profiles for each parent ester and the formed metabolite, diflunisal, were analyzed using statistical moments analysis and the two-compartment dispersion model. Data (presented as mean +/- standard error for triplicate experiments) was compared using ANOVA repeated measures, significance level P < 0.05. The hepatic availability (AUC'), the fraction of the injected dose recovered in the outflowing perfusate, for O-acetyldiflunisal (C2D = 0.21 +/- 0.03) was significantly lower than the other esters (0.34-0.38). However, R-N/f(u), the removal efficiency number R-N divided by the unbound fraction in perfusate f(u), which represents the removal efficiency of unbound ester by the liver, was significantly higher for the most lipophilic ester (O-hexanoyldiflunisal, C6D = 16.50 +/- 0.22) compared to the other members of the series (9.57 to 11.17). The most lipophilic ester, C6D, had the largest permeability surface area (PS) product (94.52 +/- 38.20 mt min-l g-l liver) and tissue distribution value VT (35.62 +/- 11.33 mL g(-1) liver) in this series. The MTT of these O-acyl esters of diflunisal were not significantly different from one another. However, the metabolite diflunisal MTTs tended to increase with the increase in the parent ester lipophilicity (11.41 +/- 2.19 s for C2D to 38.63 +/- 9.81 s for C6D). The two-compartment dispersion model equations adequately described the outflow profiles for the parent esters and the metabolite diflunisal formed from the O-acyl esters of diflunisal in the liver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intermittent low-dose heparinised saline flushes were found to be efficacious for maintaining patency of indwelling peripheral and central intravenous catheters in diabetic dogs. The catheters were flushed with 1 mL of 1 U/mL heparinised saline every two hours immediately following blood sample collection, or every 12 hours when not being used for sampling. Central catheters were flushed with saline solution first to clear the line before instillation of the heparinised saline. Patency of 54/57 (95%) of the peripheral catheters and 30/32 (94%) of the central catheters was achieved for up to 36 hours and five days, respectively. No phlebitis, or local or systemic infections were observed and, in each case, catheter failure was attributable to obstruction or extravasation. It is unlikely that there will be any contraindications to this flushing technique and its introduction may improve intravenous catheter survival and reduce catheter-associated complications in hospitalised dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the pharmacokinetics of intravenous ciprofloxacin 200 mg every 8 h in critically ill patients on continuous veno-venous haemodiafiltration (CVVHDF), one form of continuous renal replacement therapy (CRRT). Design and setting: Open, prospective clinical study in a multidisciplinary, intensive care unit in a university-affiliated tertiary referral hospital. Patients: Sis critically ill patients with acute renal failure on CVVHDF. Interventions: Timed blood and ultrafiltrate samples were collected to allow pharmacokinetics and clearances to be calculated of initial and subsequent doses of 200 mg intravenous ciprofloxacin. CVVHD was performed with 1 l/h of dialysate and 2 l/h of predilution filtration solution, producing 3 lih of dialysis effluent. The blood was pumped at 200 ml/min using a Gambro BMM-10 blood pump through a Hospal AN69HF haemofilter,. Measurements and results: Ten pharmacokinetic profiles were measured. The CVVHDF displayed a urea clearance of 42 +/- 3 ml/min, and removed ciprofloxacin with a clearance of 37 +/- 7 ml/min. This rate was 2-2.5 greater than previously published for ciprofloxacin in other forms of CRRT. On average the CVVHDF was responsible for clearing a fifth of all ciprofloxacin eliminated (21 +/- 10%). The total body clearance of ciprofloxacin was 12.2 +/- 4.3 l/h. The trough concentration following the initial dose was 0.7 +/- 0.3 mg/l. The area under the plasma concentration time curves over a 24-h period ranged from 21 to 55 mg .h l(-1). Conclusions: Intravenous ciprofloxacin 600 mg/day in critically ill patients using this form of CRRT produced adequate plasma levels for many resistant microbes found in intensive care units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thromboembolism is a frequent, life-threatening, postoperative complication of hip-fracture and total-knee-replacement surgery. Fondaparinux is a synthetic polysaccharide that selectively binds to antithrombin, the primary endogenous regulator of blood coagulation. Low molecular weight heparins, such as enoxaparin, are less specific inhibitors of coagulation. In patients undergoing hip-fracture surgery, fondaparinux is more effective than once-daily enoxaparin as prophylaxis for venous thromboembolism. Fondaparinux (25 mg/day s.c.) was also more effective than enoxaparin (30 mg s.c. b.i.d.) as prophylaxis for venous thromboembolism in elective knee surgery. These differences may be explained by the fact that there is less prophylaxis cover with enoxaparin, as it has a much shorter duration of action than fondaparinux. Thus, with the present dosing regimens, fondaparinux is probably preferable to enoxaparin for the prevention of venous thromboembolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of hepatic oxygen extraction was performed on six healthy Greyhound dogs over a two hour period. The Greyhounds were anaesthetised and a right subcostal surgical incision performed. Ultrasonic flow transducers were used to measure flow rate in the hepatic artery and the portal vein. The blood oxygen tensions in arterial blood and in the portal and hepatic veins were also measured. Hepatic oxygen extraction remained stable throughout the study, despite a steady decline in arterial blood pressure. The methodology described in this study provides a direct measure of oxygen uptake by the liver in the dog and could readily be used to investigate hepatic uptake of drugs. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The surgical cure rate for primary hyperparathyroidism is greater than 95%. For those who have recurrent or persistent disease, preoperative localization improves reoperation success rates. Selective parathyroid venous sampling (SPVS) for intact parathyroid hormone is particularly useful when non-invasive localization techniques are negative or inconclusive. Methods: We present all known cases (n = 13) between 1994 and 2002 who had venous sampling for localization at our institution prior to reoperation for recurrent or persistent primary hyperparathyroidism. Comparison was made with non-invasive localization procedures. Results of invasive and non-invasive localization were correlated with surgical findings. Results: Of the nine reoperated cases, eight had positive correlations between SPVS and operative findings and histopathology. SPVS did not reveal the parathyroid hormone source in one case with negative non-invasive localization procedures. Comparisons between SPVS, computerized tomography (CT), and parathyroid scintigraphy (MIBI) as expressed in terms of true positive (TP), false positive (FP) and false negative (FN) were: SPVS - TP 88.8%, FP 0%, FN 11.1%; CT - TP 22.2%, FP 22.2%, FN 55.5%; and MIBI - TP 33.3%, FP 0%, FN 66.6%. At least seven of the nine operated cases have been cured; another remained normocalcaemic 2 weeks after subtotal parathyroidectomy. Conclusion: In our institution SPVS has proven to be a valuable tool in cases with recurrent or persistent primary hyperparathyroidism and negative non-invasive localization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on a block clinical trial of two types of central venous catheters (CVCs): antiseptic-impregnated catheters (AIC) and non-impregnated catheters (non-AIC), on catheter tip colonization and bacteraemia. In total, 500 catheters were inserted in 390 patients over the 18 month study period, 260 (52.0%) AIC and 240 (48.0%) non-AIC. Of these, 460 (92.0%) tips (237 AIC and 223 non-AIC) were collected. While significantly fewer AIC, 14 (5.9%), than non-AIC, 30 (13.5%), catheters were colonized (P < 0.01), there was no difference in the rates of bacteraemias in the two groups (0.8% vs. 2.7%, respectively, P = 0.16). There were 6.87 (95% CI 3.38-14.26) and 16.92 (95% CI 10.61-27.12) colonized AIC and non-AIC catheters, respectively, per 1000 catheter days, a difference that was significant (P < 0.01). However, no difference emerged between bacteraemias in AIC and non-AIC catheters per 1000 catheter days measured at 0.98 (95% CI 0.24-5.54) and 3.38 (95% CI 1.29-9.34), respectively (P = 0.10). Of the 444 CVCs that were sited in the subclavian or jugular veins and had tips collected, significantly more catheters were colonized in the jugular group, 19 (20%), compared with the subclavian group, 24 (6.9%; P less than or equal to 0.01). Overall, the low rates of colonization and bacteraemia may be explained by the population studied, the policies used and the employment of a clinical nurse dedicated to CVC management. (C) 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.