122 resultados para electric variables measurement

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate a contradiction of quantum mechanics with local hidden variable theories for continuous quadrature phase amplitude (position and momentum) measurements. For any quantum state, this contradiction is lost for situations where the quadrature phase amplitude results are always macroscopically distinct. We show that for optical realizations of this experiment, where one uses homodyne detection techniques to perform the quadrature phase amplitude measurement, one has an amplification prior to detection, so that macroscopic fields are incident on photodiode detectors. The high efficiencies of such detectors may open a way for a loophole-free test of local hidden variable theories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Many guidelines advocate measurement of total or low density lipoprotein cholesterol (LDL), high density lipoprotein cholesterol (HDL), and triglycerides (TG) to determine treatment recommendations for preventing coronary heart disease (CHD) and cardiovascular disease (CVD). This analysis is a comparison of lipid variables as predictors of cardiovascular disease. METHODS: Hazard ratios for coronary and cardiovascular deaths by fourths of total cholesterol (TC), LDL, HDL, TG, non-HDL, TC/HDL, and TG/HDL values, and for a one standard deviation change in these variables, were derived in an individual participant data meta-analysis of 32 cohort studies conducted in the Asia-Pacific region. The predictive value of each lipid variable was assessed using the likelihood ratio statistic. RESULTS: Adjusting for confounders and regression dilution, each lipid variable had a positive (negative for HDL) log-linear association with fatal CHD and CVD. Individuals in the highest fourth of each lipid variable had approximately twice the risk of CHD compared with those with lowest levels. TG and HDL were each better predictors of CHD and CVD risk compared with TC alone, with test statistics similar to TC/HDL and TG/HDL ratios. Calculated LDL was a relatively poor predictor. CONCLUSIONS: While LDL reduction remains the main target of intervention for lipid-lowering, these data support the potential use of TG or lipid ratios for CHD risk prediction. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The repeatability of initial values and rate of change of EMG signal mean spectral frequency (MNF), average rectified values (ARV), muscle fiber conduction velocity (CV) and maximal voluntary contraction (MVC) was investigated in the vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles of both legs of nine healthy male subjects during voluntary, isometric contractions sustained for 50 s at 50% MVC. The values of MVC were recorded for both legs three times on each day and for three subsequent days, while the EMG signals have been recorded twice a day for three subsequent days. The degree of repeatability was investigated using the Fisher test based upon the ANalysis Of VAriance (ANOVA), the Standard Error of the Mean (SEM) and the Intraclass Correlation Coefficient (ICC). Data collected showed a high level of repeatability of MVC measurement (normalized SEM from 1.1% to 6.4% of the mean). MNF and ARV initial values also showed a high level of repeatability (ICC > 70% for all muscles and legs except right VMO). At 50% MVC level no relevant pattern of fatigue was observed for the VMO and VL muscles, suggesting that other portions of the quadriceps might have contributed to the generated effort. These observations seem to suggest that in the investigation of muscles belonging to a multi-muscular group at submaximal level, the more selective electrically elicited contractions should be preferred to voluntary contractions. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study we examined the repeatability and reliability of the surface electromyographic (sEMG) signal mean frequency (MNF), average rectified value (ARV) and conduction velocity (CV) measured for the sternocleidomastoid (SCM) and the anterior scalene (AS) muscles in nine healthy volunteers during 15-s isometric cervical flexion contractions at 50% of the maximal voluntary contraction level over 3 non-consecutive days. Repeatability and reliability estimates were obtained for the initial values and rates of change of each sEMG variable by using both the Intraclass Correlation Coefficient (ICC) and the normalised standard error of the mean (nSEM). Results from SCM indicated good levels of repeatability for the initial value and slope of ARV (ICC > 65%). For the AS, high levels of repeatability were identified for the initial value of MNF (ICC > 70%) and the slope of ARV (ICC > 75%). Values of nSEM in the range 2.8-7.2% were obtained for the initial values of MNF and CV for both SCM and AS, indicating clinically acceptable measurement precision. The low value obtained for the nSEM of the initial value of MNF for the AS, in combination with the high ICC, indicates that of all of the variables examined, this variable could offer the best normative index to distinguish between subjects with and without neck pain, and represents the sEMG variable of choice for future evaluation purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Health promotion policy frameworks, recent theorizing, and research all emphasize understanding and mobilizing environmental influences to change particular health-related behaviors in specific settings. The workplace is a key environmental setting. The Checklist of Health Promotion Environments at Worksites (CHEW) was designed as a direct observation instrument to assess characteristics of worksite environments that are known to influence health-related behaviors. Methods. The CHEW is a 112-item checklist of workplace environment features hypothesized to be associated, both positively and negatively, with physical activity, healthy eating, alcohol consumption, and smoking. The three environmental domains assessed are (1) physical characteristics of the worksite, (2) features of the information environment, and (3) characteristics of the immediate neighborhood around the workplace. The conceptual rationale and development studies for the CHEW are described, and data from observational studies of 20 worksites are reported. Results. The data on CHEW-derived environmental attributes showed generally good reliability and identified meaningful sets of variables that plausibly may influence health-related behaviors. With the exception of one information environment attribute, intraclass correlation coefficients ranged from 0.80 to 1.00. Descriptive statistics on selected physical and information environment characteristics indicated that vending machines, showers, bulletin boards, and signs prohibiting smoking were common across worksites. Bicycle racks, visible stairways, and signs related to alcohol consumption, nutrition, and health. promotion were relatively uncommon. Conclusions. These findings illustrate the types of data on environmental attributes that can be derived, their relevance for program planning, and how they can characterize variability across worksites. The CHEW is a promising observational measure that has the potential to assess environmental influences on health behaviors and to evaluate workplace health promotion programs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we examine the effects of varying several experimental parameters in the Kane quantum computer architecture: A-gate voltage, the qubit depth below the silicon oxide barrier, and the back gate depth to explore how these variables affect the electron density of the donor electron. In particular, we calculate the resonance frequency of the donor nuclei as a function of these parameters. To do this we calculated the donor electron wave function variationally using an effective-mass Hamiltonian approach, using a basis of deformed hydrogenic orbitals. This approach was then extended to include the electric-field Hamiltonian and the silicon host geometry. We found that the phosphorous donor electron wave function was very sensitive to all the experimental variables studied in our work, and thus to optimize the operation of these devices it is necessary to control all parameters varied in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reliability of measurement refers to unsystematic error in observed responses. Investigations of the prevalence of random error in stated estimates of willingness to pay (WTP) are important to an understanding of why tests of validity in CV can fail. However, published reliability studies have tended to adopt empirical methods that have practical and conceptual limitations when applied to WTP responses. This contention is supported in a review of contingent valuation reliability studies that demonstrate important limitations of existing approaches to WTP reliability. It is argued that empirical assessments of the reliability of contingent values may be better dealt with by using multiple indicators to measure the latent WTP distribution. This latent variable approach is demonstrated with data obtained from a WTP study for stormwater pollution abatement. Attitude variables were employed as a way of assessing the reliability of open-ended WTP (with benchmarked payment cards) for stormwater pollution abatement. The results indicated that participants' decisions to pay were reliably measured, but not the magnitude of the WTP bids. This finding highlights the need to better discern what is actually being measured in VVTP studies, (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Few educational campaigns have focused on bowel cancer, though studies have indicated that members of the community need and want current information about relevant issues. In order to facilitate research in this area, reliable and valid measures of community attitudes are needed. Content validity of a survey instrument was obtained through use of a Delphi process with Directors of Education from the Australia Cancer Council and focus group discussions with informed members of the public. The subsequent survey of community perceptions about colorectal cancer included a broad range of content areas related to the risk of bowel cancer, preventing and coping with bowel cancer and beliefs about susceptibility and severity. The construct validity of these content areas was investigated by use of a factor analysis and confirmation of an association with related predictor variables. Two measures related to personal influence and anticipated coping responses showed favourable psychometric properties, including moderate to high levels of internal consistency and test-retest reliability. A test of the concurrent validity of these measures requires further development of instruments related to colorectal cancer or adaptation of measures from other areas of health research. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study determined the inter-tester and intra-tester reliability of physiotherapists measuring functional motor ability of traumatic brain injury clients using the Clinical Outcomes Variable Scale (COVS). To test inter-tester reliability, 14 physiotherapists scored the ability of 16 videotaped patients to execute the items that comprise the COVS. Intra-tester reliability was determined by four physiotherapists repeating their assessments after one week, and three months later. The intra-class correlation coefficients (ICC) were very high for both inter-tester reliability (ICC > 0.97 for total COVS scores, ICC > 0.93 for individual COVS items) and intra-tester reliability (ICC > 0.97). This study demonstrates that physiotherapists are reliable in the administration of the COVS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extracting human postural information from video sequences has proved a difficult research question. The most successful approaches to date have been based on particle filtering, whereby the underlying probability distribution is approximated by a set of particles. The shape of the underlying observational probability distribution plays a significant role in determining the success, both accuracy and efficiency, of any visual tracker. In this paper we compare approaches used by other authors and present a cost path approach which is commonly used in image segmentation problems, however is currently not widely used in tracking applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increasing prevalence of salinity world-wide, the measurement of exchangeable cation concentrations in saline soils remains problematic. Two soil types (Mollisol and Vertisol) were equilibrated with a range of sodium adsorption ratio (SAR) solutions at various ionic strengths. The concentrations of exchangeable cations were then determined using several different types of methods, and the measured exchangeable cation concentrations compared to reference values. At low ionic strength (low salinity), the concentration of exchangeable cations can be accurately estimated from the total soil extractable cations. In saline soils, however, the presence of soluble salts in the soil solution precludes the use of this method. Leaching of the soil with a pre-wash solution (such as alcohol) was found to effectively remove the soluble salts from the soil, thus allowing the accurate measurement of the effective cation exchange capacity (ECEC). However, the dilution associated with this pre-washing increased the exchangeable Ca concentrations while simultaneously decreasing exchangeable Na. In contrast, when calculated as the difference between the total extractable cations and the soil solution cations, good correlations were found between the calculated exchangeable cation concentrations and the reference values for both Na (Mollisol: y=0.873x and Vertisol: y=0.960x) and Ca (Mollisol: y=0.901x and Vertisol: y=1.05x). Therefore, for soils with a soil solution ionic strength greater than 50 mM (electrical conductivity of 4 dS/m) (in which exchangeable cation concentrations are overestimated by the assumption they can be estimated as the total extractable cations), concentrations can be calculated as the difference between total extractable cations and soluble cations.