10 resultados para data acquisition system
em University of Queensland eSpace - Australia
Resumo:
The equipment used to measure magnetic fields and, electric currents in residences is described. The instrumentation consisted of current transformers, magnetic field probes and locally designed and, built signal conditioning modules. The data acquisition system was capable of unattended recording for extended time periods. The complete system was calibrated to verify its response to known physical inputs. (C) 2003 ISA-The Instrumentation Automation Society.
Resumo:
Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.
Resumo:
Neurological disease or dysfunction in newborn infants is often first manifested by seizures. Prolonged seizures can result in impaired neurodevelopment or even death. In adults, the clinical signs of seizures are well defined and easily recognized. In newborns, however, the clinical signs are subtle and may be absent or easily missed without constant close observation. This article describes the use of adaptive signal processing techniques for removing artifacts from newborn electroencephalogram (EEG) signals. Three adaptive algorithms have been designed in the context of EEG signals. This preprocessing is necessary before attempting a fine time-frequency analysis of EEG rhythmical activities, such as electrical seizures, corrupted by high amplitude signals. After an overview of newborn EEG signals, the authors describe the data acquisition set-up. They then introduce the basic physiological concepts related to normal and abnormal newborn EEGs and discuss the three adaptive algorithms for artifact removal. They also present time-frequency representations (TFRs) of seizure signals and discuss the estimation and modeling of the instantaneous frequency related to the main ridge of the TFR.
Resumo:
Aims To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echo cardiographic technology in combination with standardized data acquisition and assessment criteria. Method and Results Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 mug.kg(-1) min(-1) and atropine up to I mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (less than or equal to50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5 +/- 0.8 institutions) or three-vessel coronary artery disease (5.4 +/- 0.8 institutions) and lower in one- or two- vessel disease (5.0 +/- 0.9 and 5.2 +/- 1.0 institutions, respectively-, P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P
Resumo:
This paper reviews the key features of an environment to support domain users in spatial information system (SIS) development. It presents a full design and prototype implementation of a repository system for the storage and management of metadata, focusing on a subset of spatial data integrity constraint classes. The system is designed to support spatial system development and customization by users within the domain that the system will operate.
Resumo:
Objective: An estimation of cut-off points for the diagnosis of diabetes mellitus (DM) based on individual risk factors. Methods: A subset of the 1991 Oman National Diabetes Survey is used, including all patients with a 2h post glucose load >= 200 mg/dl (278 subjects) and a control group of 286 subjects. All subjects previously diagnosed as diabetic and all subjects with missing data values were excluded. The data set was analyzed by use of the SPSS Clementine data mining system. Decision Tree Learners (C5 and CART) and a method for mining association rules (the GRI algorithm) are used. The fasting plasma glucose (FPG), age, sex, family history of diabetes and body mass index (BMI) are input risk factors (independent variables), while diabetes onset (the 2h post glucose load >= 200 mg/dl) is the output (dependent variable). All three techniques used were tested by use of crossvalidation (89.8%). Results: Rules produced for diabetes diagnosis are: A- GRI algorithm (1) FPG>=108.9 mg/dl, (2) FPG>=107.1 and age>39.5 years. B- CART decision trees: FPG >=110.7 mg/dl. C- The C5 decision tree learner: (1) FPG>=95.5 and 54, (2) FPG>=106 and 25.2 kg/m2. (3) FPG>=106 and =133 mg/dl. The three techniques produced rules which cover a significant number of cases (82%), with confidence between 74 and 100%. Conclusion: Our approach supports the suggestion that the present cut-off value of fasting plasma glucose (126 mg/dl) for the diagnosis of diabetes mellitus needs revision, and the individual risk factors such as age and BMI should be considered in defining the new cut-off value.
Resumo:
This report describes recent updates to the custom-built data-acquisition hardware operated by the Center for Hypersonics. In 2006, an ISA-to-USB bridging card was developed as part of Luke Hillyard's final-year thesis. This card allows the hardware to be connected to any recent personal computers via a (USB or RS232) serial port and it provides a number of simple text-based commands for control of the hardware. A graphical user interface program was also updated to help the experimenter manage the data acquisition functions. Sampled data is stored in text files that have been compressed with the gzip for mat. To simplify the later archiving or transport of the data, all files specific to a shot are stored in a single directory. This includes a text file for the run description, the signal configuration file and the individual sampled-data files, one for each signal that was recorded.
Resumo:
Objective. Outcome assessment in clinical trials using the Western Ontario and McMaster University (WOMAC 3.0) Osteoarthritis Index is traditionally achieved through self-administration of the Index. However, in other areas of clinical measurement, telephone administration has been shown to be a reliable method of acquiring data that are both accurate and complete. To address this issue in knee osteoarthritis (OA), we conducted a comparative study of telephone administration by interviewer of WOMAC LK3.0 versus onsite self-completion at the hospital. Methods. Fifty consenting patients with knee OA were randomized to complete the WOMAC LK3.0 Index by telephone interview one day, followed by onsite completion the following day, or vice versa. Neither patients nor interviewers had access to any prior scores. Results. The mean age of the 50 patients was 66.3 years (range 44-82); 34 (68%) were female and 16 (32%) male. There was excellent agreement between the mean office and telephone scores, with mean differences for the WOMAC LK3.0 pain, stiffness, and function subscale scores and total score of 0.09, 0.12, 0.78, and 0.98, respectively. These differences were well within the respective protocol defined equivalence criteria of +/- 1.7, +/- 0.9, +/- 6.4, and +/- 9.1, and represented differences from office scores of 0.9, 2.6, 2.4, and 2.2%, respectively. Conclusion. The use of telephone interviews for the WOMAC LK3.0 Index is a valid method of obtaining OA outcome measurements. These observations have important implications for designing data acquisition strategies for future OA clinical trials and for longterm observational studies.