24 resultados para continuous biometric authentication system

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

User requirements of multimedia authentication are various. In some cases, the user requires an authentication system to monitor a set of specific areas with respective sensitivity while neglecting other modification. Most current existing fragile watermarking schemes are mixed systems, which can not satisfy accurate user requirements. Therefore, in this paper we designed a sensor-based multimedia authentication architecture. This system consists of sensor combinations and a fuzzy response logic system. A sensor is designed to strictly respond to given area tampering of a certain type. With this scheme, any complicated authentication requirement can be satisfied, and many problems such as error tolerant tamper method detection will be easily resolved. We also provided experiments to demonstrate the implementation of the sensor-based system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Although both strength training (ST) and endurance training (ET) seem to be beneficial in type 2 diabetes mellitus (T2D), little is known about post-exercise glucose profiles. The objective of the study was to report changes in blood glucose (BG) values after a 4-month ET and ST programme now that a device for continuous glucose monitoring has become available. Materials and methods Fifteen participants, comprising four men age 56.5 +/- 0.9 years and 11 women age 57.4 +/- 0.9 years with T2D, were monitored with the MiniMed (Northridge, CA, USA) continuous glucose monitoring system (CGMS) for 48 h before and after 4 months of ET or ST. The ST consisted of three sets at the beginning, increasing to six sets per week at the end of the training period, including all major muscle groups and ET performed with an intensity of maximal oxygen uptake of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min three times a week. Results A total of 17 549 single BG measurements pretraining (619.7 +/- 39.8) and post-training (550.3 +/- 30.1) were recorded, correlating to an average of 585 +/- 25.3 potential measurements per participant at the beginning and at the end of the study. The change in BG-value between the beginning (132 mg dL(-1)) and the end (118 mg dL(-1)) for all participants was significant (P = 0.028). The improvement in BG-value for the ST programme was significant (P = 0.02) but for the ET no significant change was measured (P = 0.48). Glycaemic control improved in the ST group and the mean BG was reduced by 15.6% (Cl 3-25%). Conclusion In conclusion, the CGMS may be a useful tool in monitoring improvements in glycaemic control after different exercise programmes. Additionally, the CGMS may help to identify asymptomatic hypoglycaemia or hyperglycaemia after training programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Marathon running is growing in popularity, and many diabetic patients are participating in various marathon races all over the world each year. This study aimed to investigate the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) during a marathon run in patients with well-controlled diabetes mellitus using a continuous glucose monitoring system (CGMS). Five subjects with type 1 and one patient with type 2 diabetes mellitus were monitored with the Medtronic MiniMed CGMS during the 2002 Vienna City Marathon (n = 3) or the Fernwarme run (n = 3) long distance runs of 42.19/15.8 km. All six patients finished their course. The CGSM system was well tolerated in all patients over an average duration of 34 +/- 4.0 hours and it did not limit the patients' activities. The mean running time for the Vienna city marathon was 257 +/- 8 min (247 to 274 min) and for the Fernwarme run 134 +/- 118 min (113 to 150 min). A total of 1470 blood glucose measurements (mean 245 readings per subject) were performed. During and after the marathons frequent hypo and hyperglycemic episodes with and without clinical symptoms were measured. Our data confirm that the CGMS may help to identify asymptomatic hypoglycemia or hyperglycemia during and after a long distance run. The system may also be helpful to improve our understanding about the individual changes of glucose during and after a marathon and may protect hypoglycemic or hyperglycemic periods in future races.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anaerobic digestion of lignocellulosic material is carried out effectively in many natural microbial ecosystems including the rumen. A rumen-enhanced anaerobic sequencing batch reactor was used to investigate cellulose degradation to give analysis of overall process stoichiometry and rates of hydrolysis. The reactor achieved VFA production rates of 207-236 mg COD/L/h at a loading rate of 10 g/L/d. Overloading of the reactor resulted in elevated production of propionic acid, and on occasion, the presence of succinic acid. With improvements in mixing and solids wasting, the anaerobic sequencing batch reactor system could enable full-scale application of the process for treatment of cellulosic waste material.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Action systems are a framework for reasoning about discrete reactive systems. Back, Petre and Porres have extended these action systems to continuous action systems, which can be. used to model hybrid systems. In this paper we define a refinement relation, and develop practical data refinement rules for continuous action systems. The meaning of continuous action systems is expressed in terms of a mapping from continuous action systems to action systems. First, we present a new mapping from continuous act ion systems to action systems, such that Back's definition of trace refinement is correct with respect to it. Second, we present a stream semantics that is compatible with the trace semantics, but is preferable to it because it is more general. Although action system trace refinement rules are applicable to continuous action systems with a stream semantics, they are not complete. Finally, we introduce a new data refinement rule that is valid with respect to the stream semantics and can be used to prove refinements that are not possible in the trace semantics, and we analyse the completeness of our new rule in conjunction with the existing trace refinement rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Control of chaos in the single-mode optically pumped far-infrared (NH3)-N-15 laser is experimentally demonstrated using continuous time-delay control. Both the Lorenz spiral chaos and the detuned period-doubling chaos exhibited by the laser have been controlled. While the laser is in the Lorenz spiral chaos regime the chaos has been controlled both such that the laser output is cw, with corrections of only a fraction of a percent necessary to keep it there, and to period one. The laser has also been controlled while in the period-doubling chaos regime, to both the period-one and -two states.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multisegment percolation system (MSPS) consisting of 25 individual collection wells was constructed to study the effects of localised soil heterogeneities on the transport of solutes in the vadose zone. In particular, this paper discusses the transport of water and nutrients (NO3-, Cl-, PO43-) through structurally stable, free-draining agricultural soil from Victoria, Australia. A solution of nutrients was irrigated onto the surface of a large undisturbed soil core over a 12-h period. This was followed by a continuous irrigation of distilled water at a fate which did not cause pending for a further 18 days. During this time, the volume of leachate and the concentration of nutrients in the leachate of each well were measured. Very significant variation in drainage patterns across a small spatial scale was observed. Leaching of nitrate-nitrogen and chloride from the core occurred two days after initial application. However, less than 1% of the total applied phosphate-phosphorus leached from the soil during the 18-day experiment, indicating strong adsorption. Our experiments indicate considerable heterogeneity in water flow patterns and solute leaching on a small spatial scale. These results have significant ramifications for modelling solute transport and predicting nutrient loadings on a larger scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To demonstrate the potential of GIS (geographic information system) technology and ARIA (Accessibility/Remoteness Index for Australia) as tools for medical workforce and health service planning in Australia. Design: ARIA is an index of remoteness derived by measuring road distance between populated localities and service centres. A continuous variable of remoteness from 0 to 12 is generated for any location in Australia. We created a GIS, with data on location of general practitioner services in non-metropolitan South Australia derived from the database of HUMPS (Rural Undergraduate Medical Placement System), and estimated, for the 1170 populated localities in South Australia, the accessibility/inaccessibility of the 109 identified GP services. Main outcome measures: Distance from populated locality to GP services. Results: Distance from populated locality to GP service ranged from 0 to 677 km (mean, 58 km). In all, 513 localities (43%) had a GP service within 20 km (for the majority this meant located within the town). However, for 173 populated localities (15%), the nearest GP service was more than 80 km away. There was a strong correlation between distance to GP service and ARIA value for each locality (0.69; P<0.05). Conclusions: GP services are relatively inaccessible to many rural South Australian communities. There is potential for GIS and for ARIA to contribute to rational medical workforce and health service planning. Adding measures of health need and more detailed data on types and extent of GP services provided will allow more sophisticated planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The St. Lawrence Island polynya (SLIP) is a commonly occurring winter phenomenon in the Bering Sea, in which dense saline water produced during new ice formation is thought to flow northward through the Bering Strait to help maintain the Arctic Ocean halocline. Winter darkness and inclement weather conditions have made continuous in situ and remote observation of this polynya difficult. However, imagery acquired from the European Space Agency ERS-1 Synthetic Aperture Radar (SAR) has allowed observation of the St. Lawrence Island polynya using both the imagery and derived ice displacement products. With the development of ARCSyM, a high resolution regional model of the Arctic atmosphere/sea ice system, simulation of the SLIP in a climate model is now possible. Intercomparisons between remotely sensed products and simulations can lead to additional insight into the SLIP formation process. Low resolution SAR, SSM/I and AVHRR infrared imagery for the St. Lawrence Island region are compared with the results of a model simulation for the period of 24-27 February 1992. The imagery illustrates a polynya event (polynya opening). With the northerly winds strong and consistent over several days, the coupled model captures the SLIP event with moderate accuracy. However, the introduction of a stability dependent atmosphere-ice drag coefficient, which allows feedbacks between atmospheric stability, open water, and air-ice drag, produces a more accurate simulation of the SLIP in comparison to satellite imagery. Model experiments show that the polynya event is forced primarily by changes in atmospheric circulation followed by persistent favorable conditions: ocean surface currents are found to have a small but positive impact on the simulation which is enhanced when wind forcing is weak or variable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Consider a tandem system of machines separated by infinitely large buffers. The machines process a continuous flow of products, possibly at different speeds. The life and repair times of the machines are assumed to be exponential. We claim that the overflow probability of each buffer has an exponential decay, and provide an algorithm to determine the exact decay rates in terms of the speeds and the failure and repair rates of the machines. These decay rates provide useful qualitative insight into the behavior of the flow line. In the derivation of the algorithm we use the theory of Large Deviations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We obtain the finite-temperature unconditional master equation of the density matrix for two coupled quantum dots (CQD's) when one dot is subjected to a measurement of its electron occupation number using a point contact (PC). To determine how the CQD system state depends on the actual current through the PC device, we use the so-called quantum trajectory method to derive the zero-temperature conditional master equation. We first treat the electron tunneling through the PC barrier as a classical stochastic point process (a quantum-jump model). Then we show explicitly that our results can be extended to the quantum-diffusive limit when the average electron tunneling rate is very large compared to the extra change of the tunneling rate due to the presence of the electron in the dot closer to the PC. We find that in both quantum-jump and quantum-diffusive cases, the conditional dynamics of the CQD system can be described by the stochastic Schrodinger equations for its conditioned state vector if and only if the information carried away from the CQD system by the PC reservoirs can be recovered by the perfect detection of the measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the conditional quantum dynamics of an electron tunneling between two quantum dots subject to a measurement using a low transparency point contact or tunnel junction. The double dot system forms a single qubit and the measurement corresponds to a continuous in time readout of the occupancy of the quantum dot. We illustrate the difference between conditional and unconditional dynamics of the qubit. The conditional dynamics is discussed in two regimes depending on the rate of tunneling through the point contact: quantum jumps, in which individual electron tunneling current events can be distinguished, and a diffusive dynamics in which individual events are ignored, and the time-averaged current is considered as a continuous diffusive variable. We include the effect of inefficient measurement and the influence of the relative phase between the two tunneling amplitudes of the double dot/point contact system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A field experiment compared two rice (Oryza sativa L.) cropping systems: paddy or raised beds with continuous furrow irrigation; and trialled four cultivars: Starbonnet, Lemont, Amaroo and Ceysvoni, and one test line YRL39; that may vary in adaptation to growth on raised beds. The grain yield of rice ranged from 740 to 1250 g/m(2) and was slightly greater in paddy than on raised beds. Although there were early growth responses to fertilizer nitrogen on raised beds, the crop nitrogen content at maturity mostly exceeded 20 g/m(2) in both systems, so nitrogen was unlikely to have limited yield. Ceysvoni yielded best in both systems, a result of good post-anthesis growth and larger grain size, although its whole-grain mill-out percentage was poor relative to the other cultivars. Starbonnet and Lemont yielded poorly on raised beds, associated with too few tillers and too much leaf area. When grown on raised beds all cultivars experienced a delay in anthesis resulting in more tillers, leaf area and dry weight at anthesis, and probably a greater yield potential. The growth of rice after anthesis, however, was similar on raised beds and in paddy, so reductions in harvest index and grain size on raised beds were recorded. The data indicated that water supply was not a major limitation to rice growth on raised beds, but slower crop development was an issue that would affect the use of raised beds in a cropping system, especially in rice-growing areas where temperatures are too cool for optimal crop development. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Penalizing line management for the occurrence of lost time injuries has in some cases had unintended negative consequences. These are discussed. An alternative system is suggested that penalizes line management for accidents where the combination of the probability of recurrence and the maximum reasonable consequences such a recurrence may have exceeds an agreed limit. A reward is given for prompt effective control of the risk to below the agreed risk limit. The reward is smaller than the penalty. High-risk accidents require independent investigation by a safety officer using analytical techniques. Two case examples are given to illustrate the system. Continuous safety improvement is driven by a planned reduction in the agreed risk limit over time and reward for proactive risk assessment and control.