7 resultados para automatic data entry

em University of Queensland eSpace - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the increasing demand on healthcare systems it is imperative that all care is provided as efficiently and effectively as possible. Technology within the medical domain offers an exciting opportunity to augment work practices in order to meet these needs. This research project explores the implications of the interrupt-driven nature of work in clinical situations on documentation within an environment that increasingly involves electronic health records (EHRs). Midwives in a busy maternity ward were observed and interviewed about the work practices they employed to document information associated with patient care. The results showed that the interrupt-driven nature of the workplace, a feature common to many healthcare settings, led to a tension between the work and the work to document the work. Further, the IT environment in which the information was collected was not designed to cater for frequent interruption of the data entry process. Several recommendations for improving the IT environment are proposed to support health professionals in documenting patient data whilst attending to the interruptions. The recommendations include timeout screens, push technology, use of handheld PDAs, and cues to augment documentation in an interrupted session. Copyright © 2008 RMIT Publishing

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents tympanometric normative data for Australian children at school entry in view of the lack of age-specific population-based data for this group. Participants were 327 children (164 boys, 163 girls) aged between 5 and 6 years, who had no history of middle ear infection, and passed pure-tone screening at 20 dB HL. Normative values for static admittance (SA), ear canal volume (ECV), tympanometric peak pressure, tympanometric width (TW) and tympanometric gradient were established. Based on these normative data, the use of the ASHA (1997) guidelines for medical referral, in which ECV > 1.0 ml in the presence of a flat tympanogram, SA < 0.3 ml, or TW > 200 daPa may not provide the best criteria for Australian children aged between 5 and 6 years. If SA < 0.3 ml were used instead of SA < 0.16 ml, a greater proportion of Australian children would have failed tympanometry, thus increasing the false alarm rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An approach and strategy for automatic detection of buildings from aerial images using combined image analysis and interpretation techniques is described in this paper. It is undertaken in several steps. A dense DSM is obtained by stereo image matching and then the results of multi-band classification, the DSM, and Normalized Difference Vegetation Index (NDVI) are used to reveal preliminary building interest areas. From these areas, a shape modeling algorithm has been used to precisely delineate their boundaries. The Dempster-Shafer data fusion technique is then applied to detect buildings from the combination of three data sources by a statistically-based classification. A number of test areas, which include buildings of different sizes, shape, and roof color have been investigated. The tests are encouraging and demonstrate that all processes in this system are important for effective building detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Development of an automatic measurement algorithm and comparison with manual measurement methods. Objectives. To develop a new computer-based method for automatic measurement of vertebral rotation in idiopathic scoliosis from computed tomography images and to compare the automatic method with two manual measurement techniques. Summary of Background Data. Techniques have been developed for vertebral rotation measurement in idiopathic scoliosis using plain radiographs, computed tomography, or magnetic resonance images. All of these techniques require manual selection of landmark points and are therefore subject to interobserver and intraobserver error. Methods. We developed a new method for automatic measurement of vertebral rotation in idiopathic scoliosis using a symmetry ratio algorithm. The automatic method provided values comparable with Aaro and Ho's manual measurement methods for a set of 19 transverse computed tomography slices through apical vertebrae, and with Aaro's method for a set of 204 reformatted computed tomography images through vertebral endplates. Results. Confidence intervals (95%) for intraobserver and interobserver variability using manual methods were in the range 5.5 to 7.2. The mean (+/- SD) difference between automatic and manual rotation measurements for the 19 apical images was -0.5 degrees +/- 3.3 degrees for Aaro's method and 0.7 degrees +/- 3.4 degrees for Ho's method. The mean (+/- SD) difference between automatic and manual rotation measurements for the 204 endplate images was 0.25 degrees +/- 3.8 degrees. Conclusions. The symmetry ratio algorithm allows automatic measurement of vertebral rotation in idiopathic scoliosis without intraobserver or interobserver error due to landmark point selection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Semantic priming occurs when a subject is faster in recognising a target word when it is preceded by a related word compared to an unrelated word. The effect is attributed to automatic or controlled processing mechanisms elicited by short or long interstimulus intervals (ISIs) between primes and targets. We employed event-related functional magnetic resonance imaging (fMRI) to investigate blood oxygen level dependent (BOLD) responses associated with automatic semantic priming using an experimental design identical to that used in standard behavioural priming tasks. Prime-target semantic strength was manipulated by using lexical ambiguity primes (e.g., bank) and target words related to dominant or subordinate meaning of the ambiguity. Subjects made speeded lexical decisions (word/nonword) on dominant related, subordinate related, and unrelated word pairs presented randomly with a short ISI. The major finding was a pattern of reduced activity in middle temporal and inferior prefrontal regions for dominant versus unrelated and subordinate versus unrelated comparisons, respectively. These findings are consistent with both a dual process model of semantic priming and recent repetition priming data that suggest that reductions in BOLD responses represent neural priming associated with automatic semantic activation and implicate the left middle temporal cortex and inferior prefrontal cortex in more automatic aspects of semantic processing.