2 resultados para amoxycillin-clavulanate

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous infusion (CI) ticarcillin-clavulanate is a potential therapeutic improvement over conventional intermittent dosing because the major pharmacodynamic (PD) predictor of efficacy of beta-lactams is the time that free drug levels exceed the MIC. This study incorporated a 6-year retrospective arm evaluating efficacy and safety of CI ticarcillin-clavulanate in the home treatment of serious infections and a prospective arm additionally evaluating pharmacokinetics (PK) and PD. In the prospective arm, steady-state serum ticarcillin and clavulanate levels and MIC testing of significant pathogens were performed. One hundred and twelve patients (median age, 56 years) were treated with a CI dose of 9.3-12.4 g/day and mean CI duration of 18.0 days. Infections treated included osteomyelitis (50 patients), septic arthritis (6), cellulitis (17), pulmonary infections (12), febrile neutropenia (7), vascular infections (7), intra-abdominal infections (2), and Gram-negative endocarditis (2); 91/112 (81%) of patients were cured, 14 (13%) had partial response and 7 (6%) failed therapy. Nine patients had PICC line complications and five patients had drug adverse events. Eighteen patients had prospective PK/PD assessment although only four patients had sufficient data for a full PK/PD evaluation (both serum steady-state drug levels and ticarcillin and clavulanate MICs from a bacteriological isolate), as this was difficult to obtain in home-based patients, particularly as serum clavulanate levels were found to deteriorate rapidly on storage. Three of four patients with matched PK/PD assessment had free drug levels exceeding the MIC of the pathogen. Home Cl of ticarcillin-clavulanate is a safe, effective, convenient and practical therapy and is a therapeutic advance over traditional intermittent dosing when used in the home setting. (c) 2005 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a diagnostic algorithm for pulmonary tuberculosis based on smear microscopy and objective response to trial of antibiotics. SETTING: Adult medical wards, Hlabisa Hospital, South Africa, 1996-1997. METHODS: Adults with chronic chest symptoms and abnormal chest X-ray had sputum examined for Ziehl-Neelsen stained acid-fast bacilli by light microscopy. Those with negative smears were treated with amoxycillin for 5 days and assessed. Those who had not improved were treated with erythromycin for 5 days and reassessed. Response was compared with mycobacterial culture. RESULTS: Of 280 suspects who completed the diagnostic pathway, 160 (57%) had a positive smear, 46 (17%) responded to amoxycillin, 34 (12%) responded to erythromycin and 40 (14%) were treated as smear-negative tuberculosis. The sensitivity (89%) and specificity (84%) of the full algorithm for culture-positive tuberculosis were high. However, 11 patients (positive predictive value [PPV] 95%) were incorrectly diagnosed with tuberculosis, and 24 cases of tuberculosis (negative predictive value [NPV] 70%) were not identified. NPV improved to 75% when anaemia was included as a predictor. Algorithm performance was independent of human immunodeficiency virus status. CONCLUSION: Sputum smear microscopy plus trial of antibiotic algorithm among a selected group of tuberculosis suspects may increase diagnostic accuracy in district hospitals in developing countries.