24 resultados para accuracy of machining
em University of Queensland eSpace - Australia
Resumo:
Investment casting is often used to produce fully functional prototype components from sacrificial patterns. These patterns (prototypes) may be made using specialized rapid prototyping techniques such as stereolithography or three-dimensional printing. When multiple functional prototypes are required, interim tools for making wax patterns are employed. The objective of this research work was to determine the precision and accuracy of wax patterns produced using several prototype tools. Linear contraction was used to determine the accuracy as a function of the wax injection parameters used in low-pressure injection moulding. Wax patterns were produced using polyurethane and silicone rubber tools. It has been shown that the accuracy of patterns from both tools is similar. However, silicone tools produce patterns with much higher contraction than those produced by polyurethane tools. Unconstrained patterns dimensions contracted as much as 3.44 +/- 0.40 per cent and 1.70 +/- 0.60 per cent for silicone and polyurethane tools respectively. The constrained dimensions contracted by 2.20 +/- 0.20 per cent in the case of silicone tools and 1.40 +/- 0.20 per cent in the case of polyurethane tools.
Resumo:
Hitting a moving target demands that movement is both spatially and temporally accurate. Recent experiments have begun to reveal how performance of such actions depends on the spatial and temporal accuracy requirements of the task. The results suggest a simple strategy for achieving spatiotemporal accuracy using brief, high-speed movements.
Resumo:
Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Resumo:
OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.
Resumo:
Achievement of steady state during indirect calorimetry measurements of resting energy expenditure (REE) is necessary to reduce error and ensure accuracy in the measurement. Steady state is often defined as 5 consecutive min (5-min SS) during which oxygen consumption and carbon dioxide production vary by +/-10%. These criteria, however, are stringent and often difficult to satisfy. This study aimed to assess whether reducing the time period for steady state (4-min SS or 3-min SS) produced measurements of REE that were significantly different from 5-min SS. REE was measured with the use of open-circuit indirect calorimetry in 39 subjects, of whom only 21 (54%) met the 5-min SS criteria. In these 21 subjects, median biases in REE between 5-min SS and 4-min SS and between 5-min SS and 3-min SS were 0.1 and 0.01%, respectively. For individuals, 4-min SS measured REE within a clinically acceptable range of +/-2% of 5-min SS, whereas 3-min SS measured REE within a range of -2-3% of 5-min SS. Harris-Benedict prediction equations estimated REE for individuals within +/-20-30% of 5-min SS. Reducing the time period of steady state to 4 min produced measurements of REE for individuals that were within clinically acceptable, predetermined limits. The limits of agreement for 3-min SS fell outside the predefined limits of +/-2%; however, both 4-min SS and 3-min SS criteria greatly increased the proportion of subjects who satisfied steady state within smaller limits than would be achieved if relying on prediction equations.
Resumo:
Videoconferencing has become a routine technique for the post-acute burns care of children in Queensland. We compared the agreement between clinical assessments conducted via videoconference and assessments conducted in the conventional, face-to-face manner (FTF). A total of 35 children with a previous burn injury were studied. Twenty-five children received three consecutive assessments: first FTF by a consultant in the outpatient department, then by a second consultant who reviewed the patient via videoconference, and then by the second consultant in person. The second consultant also reviewed another 10 children twice. At each review, the following variables were measured: scar colour, scar thickening, contractures, range of motion, the patient's level of general activity, any breakdown of the graft site, and adequacy of the consultation. Agreement between the two consultants when seeing patients FTF was moderately high, with an overall concordance of 85%. When videoconferencing was used, the level of agreement was almost the same, at 84%. If one consultant reviewed patients FTF first and then via videoconference, the overall concordance was 98%; if the process was reversed, the overall concordance was 97%. This study confirms that the quality of information collected during a videoconference appointment is comparable to that collected during a traditional, FTF appointment for a follow-up burns consultation.
Resumo:
This study was designed to assess the effect of sequence mismatches between primers and their targets on viral quantitative PCR. Numerous primers were constructed incorporating various mismatches with a target sequence on the BKV T antigen gene. When using these primers in standard Taqman two-step cycling conditions, as few as two mismatches in a single primer increased cycle threshold values and significantly influenced the calculation of viral load. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
A meta-analysis of rapid (
Resumo:
Background. Myocardial viability (VM) assessment based on wall motion scoring (WMS) with dobutamine echo (DbE) is difficult and subjective. New quantitative techniques such as strain rate imaging (SRI) correspond with isotopic techniques but their ability to predict functional recovery (FR) after revascularization is unclear. Methods. Stable post-MI pts (n=43, age 63±9, EF 36±6%) underwent SRI during DbE. WMS evidence of VM was based on lowdose augmentation at DbE. SR, end-systolic strain (ESS), post-systolic strain (PSS) and timing were analyzed at rest and low dose in abnormal segts. Pts were followed for 9±12 months; FR was defined as segt improvement on post-revascularization images. Results: Of 180 segts with abnormal resting function, 83 showed FR and 97 did not. Resting parameters were not predictive of recovery; resting post-systolic shortening had a sensitivity and specificity