Resumo:
Aims Topical sunscreens are routinely applied to the skin by a large percentage of the population. This study assessed the extent of absorption of a number of common chemical sunscreen agents into and through human skin following application of commercially available products. Methods Sunscreen products were applied to excised human epidermis in Franz diffusion cells with the amount penetrating into and across the epidermis assessed by h.p.l.c. for 8 h following application. Results All sunscreen agents investigated penetrated into the skin (0.25 g m(-2) or 14% of applied dose), but only benzophenone-3 passed through the skin in significant amounts (0.08 g m(-2) or 10% of the applied dose). With one exception, suncreen agents in corresponding products marketed for adults and children had similar skin penetration profiles. Conclusions Whilst limited absorption across the skin was observed for the majority of the sunscreens tested, benzophenone-3 demonstrated sufficiently high penetration to warrant further investigation of its continued application.
Resumo:
This study provides an investigation of the availability of octyl salicylate (OS), a common sunscreen agent, from liquid paraffin and the effect of OS on skin permeability. A model membrane system to isolate the vehicle effect from membrane permeability has been developed. Partitioning of OS between liquid paraffin and aqueous receptor phases was conducted. Partition coefficients increased with increase in OS concentration. A range of OS concentrations in liquid paraffin was diffused across human epidermis and synthetic membranes into 4% bovine serum albumin in phosphate-buffered saline and 50% ethanol. Absorption profiles of OS obtained from silicone and low-density polyethylene (LDPE) membranes were similar to each other but higher than for the high-density polyethylene [HDPE (3 times)] membrane and human epidermis (15 times). The steady state fluxes and apparent permeability coefficients (K-p') obtained from the diffusion studies showed the same trends with all membranes, except for the HDPE membrane which showed greater increase in flux and K-p' at concentrations above 30%. IR spectra showed that several bands of OS were shifted with concentrations, and the molecular models further suggested that the main contribution to the self-association is from non-1,4 van der Waals interactions.
Resumo:
The present paper addresses two major concerns that were identified when developing neural network based prediction models and which can limit their wider applicability in the industry. The first problem is that it appears neural network models are not readily available to a corrosion engineer. Therefore the first part of this paper describes a neural network model of CO2 corrosion which was created using a standard commercial software package and simple modelling strategies. It was found that such a model was able to capture practically all of the trends noticed in the experimental data with acceptable accuracy. This exercise has proven that a corrosion engineer could readily develop a neural network model such as the one described below for any problem at hand, given that sufficient experimental data exist. This applies even in the cases when the understanding of the underlying processes is poor. The second problem arises from cases when all the required inputs for a model are not known or can be estimated with a limited degree of accuracy. It seems advantageous to have models that can take as input a range rather than a single value. One such model, based on the so-called Monte Carlo approach, is presented. A number of comparisons are shown which have illustrated how a corrosion engineer might use this approach to rapidly test the sensitivity of a model to the uncertainities associated with the input parameters. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
The development of solutions that prevent dehydration or promote adequate re-hydration play a vital role in preventing fatigue during exercise, however, the methods commonly used to assess the hydration ability of such solutions are invasive and often assess the components of absorption separately. This paper describes using a non-invasive deuterium tracer technique that assesses gastric emptying and intestinal absorption simultaneously to evaluate the uptake of water during rest and exercise. The kinetics of absorption are further examined by mathematical modelling of the data generated. For the rest group, 0.05 g/kg of body weight of deuterium, contained in gelatine capsules, was ingested with ordinary tap water and saliva samples were collected every 5 min for one hour while the subject remained seated. The deuterium was administered as above for the exercise group but sample collection was during one hour of exercise on a treadmill at 55% of the subject's maximum heart rate. The enrichment data for each subject were mathematically modelled and the parameters obtained were compared across groups using an independent samples t-test. Compared with the rest condition, the exercise group showed delayed absorption of water as indicated by significant differences for the modelling parameters t(2), t(1/2), maximum absorption rate and solution absorption amount at t(1). Labelling with a deuterium tracer is a good measure of the relative rate ingested fluids are absorbed by the body. Mathematical modelling of the data generates rates of maximum absorption and allows calculation of the percentage of the solution that is absorbed at any given time during the testing period. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Objective-To investigate in vitro transdermal absorption of fentanyl from patches through skin samples obtained from various anatomic regions of dogs. Sample Population-Skin samples from 5 Greyhounds. Procedure-Skin samples from the dogs' thoracic, neck, and groin regions were collected postmortem and frozen. After samples were thawed, circular sections were cut and placed in Franz-type diffusion cells in a water bath (32degreesC). A commercial fentanyl patch, attached to an acetate strip with a circular hole, was applied to each skin sample. Cellulose strips were used as control membranes. Samples of receptor fluid in the diffusion cells were collected at intervals for 48 hours, and fentanyl concentrations were analyzed by use of high-performance liquid chromatography. Results-Mean +/- SD release rate of fentanyl from the patch, defined by its absorption rate through the non-rate-limiting cellulose membrane, was linear during the first 8 hours (2.01 +/- 0.05 pg/cm(2) of cellulose membrane/h) and then decreased. Fentanyl passed through skin from the groin region at a faster rate and with a significantly shorter lag time, compared with findings in neck or thoracic skin samples. Conclusions and Clinical Relevance-In vitro, fentanyl from a patch was absorbed more quickly and to a greater extent through skin collected from the groin region of dogs, compared with skin samples from the thoracic and neck regions. Placement of fentanyl patches in the groin region of dogs may decrease the lag time to achieve analgesia perioperatively; however, in vivo studies are necessary to confirm these findings.
Resumo:
The effect of region of application on the percutaneous penetration of solutes with differing lipophilicity was investigated in canine skin. Skin from the thorax, neck, back, groin, and axilla regions was harvested from Greyhound dogs and placed in Franz-type diffusion cells. Radiolabelled (C-14) ethanol (Log P 0.19) or hexanol (Log P 1.94) was applied to each skin section for a total of 5 h. The permeability coefficient (k(P), cm h(-1)) and residue of alcohol remaining in the skin were significantly (P = 0.001) higher for hexanol compared to ethanol. In contrast, ethanol had a far greater maximum flux (J(max), mol (cm(2))(-1) h(-1)) than hexanol (P = 0.001). A comparison of regional differences shows the k(P) and Jmax for ethanol in the groin was significantly lower (P = 0.035) than the back. The k(P) and Jmax for hexanol were significantly higher (P = 0.001) in the axilla than the other four skin sites. An understanding of factors influencing percutaneous drug movement is important when formulating topical preparations for the dog. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
We present new simulation results for the packing of single-center and three-center models of carbon dioxide at high pressure in carbon slit pores. The former shows a series of packing transitions that are well described by our density functional theory model developed earlier. In contrast, these transitions are absent for the three-center model. Analysis of the simulation results shows that alternations of flat-lying molecules and rotated molecules can occur as the pore width is increased. The presence or absence of quadrupoles has negligible effect on these high-density structures.
Resumo:
A review with 93 references. Heparins are high molecular weight, hydrophilic polyanions, which are unstable under acidic conditions; and therefore they exhibit poor oral bioavailability. Consequently they must be administered via the parenteral route which is expensive, inconvenient, and limits use by outpatients. The development of an oral form of heparin is warranted. This review examined the literature, mostly published between January 2000 and January 2005, pertaining to the gastrointestinal absorption of heparin by lipidization or coadministration with penetration enhancers. A lipidization strategy that was examined involved conjugation of low molecular weight heparin with deoxycholic acid. The majority of studies examined the ability of different formulations, typically utilizing penetration enhancers, to improve heparin bioavailability. The penetration enhancers used included fatty acids, Labrasol™, Gelucire 44/14™, polycationic lipophilic-core dendrons, saponins, mono-N-carboxymethyl chitosan, Carbopol® 934P, a combination of thiolated polycarbophil and glutathione, polymeric nanoparticles, polymeric microparticles, sodium N-[8-(2-hydroxybenzoyl) amino]caprylate (SNAC), and sodium N-[10-(2-hydroxybenzoyl)amino]decanoate (SNAD). The variety of models used and doses of heparin/penetration enhancers applied, however, made it difficult to compare the results between studies. Nevertheless, all of the reviewed drug delivery systems showed therapeutic value and confirmation of the promising results obtained from animal studies, by progression to clinical trials, is necessary. Overall, progress has been made in the quest for an oral heparin formulation.
Resumo:
Objective-To determine the effects of various vehicles on the penetration and retention of hydrocortisone applied to canine skin. Sample Population-20 canine skin samples obtained from the thorax, neck, and groin regions of 5 Greyhounds. Procedure-Skin was harvested from dogs after euthanasia and stored at -20 degrees C until required. The skin was then defrosted and placed into diffusion cells, which were maintained at approximately 32 degrees C by a water bath. Saturated solutions of hydrocortisone that contained trace amounts of radiolabelled [C-14]-hydrocortisone in each vehicle (ie, PBS solution [PBSS] alone, 50% ethanol [EtOH] in PBSS [wt/wt], and 50% propylene glycol in PBSS [wt/wt]) were applied to the outer (stratum corneum) surface of each skin sample, and aliquots of receptor fluid were collected for 24 hours and analyzed for hydrocortisone. Results-The maximum flux of hydrocortisone was significantly higher for all sites when dissolved in a vehicle containing 50% EtOH, compared with PBSS alone or 50% propylene glycol, with differences more prominent in skin from the neck region. In contrast, higher residues of hydrocortisone were found remaining within the skin when PBSS alone was used as a vehicle, particularly in skin from the thorax and neck. Conclusions and Clinical Relevance-Penetration of topically applied hydrocortisone is enhanced when EtOH is used in vehicle formulation. Significant regional differences (ie, among the thorax, neck, and groin areas) are also found in the transdermal penetration and skin retention of hydrocortisone. Variability in clinical response to hydrocortisone can be expected in relation to formulation design and site of application.
Resumo:
The skin localization of steroids following topical application is largely unknown. We determined the distribution of five steroids in human skin using excised epidermal, dermal, and full-thickness membranes in vitro. There was no significant difference in steroid maximum flux through epidermal and full-thickness membranes, other than significantly lower fluxes for the most polar steroid, aldosterone. Hydrocortisone had the highest dermal diffusivity and dermal penetration, and the accumulation of hydrocortisone and corticosterone was higher than that of the other steroids. Slower penetration and higher accumulation in the viable epidermis of progesterone in full-thickness skin were consistent with dermal penetration limitation effects associated with high lipophilicity. Copyright (c) 2006 S. Karger AG, Basel