54 resultados para Ventilation radiator

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to determine whether antenatal corticosteroids improve perinatal adaptation of the pulmonary circulation in lambs with lung hypoplasia (LH). LH was induced in 12 ovine fetuses between 105 and 140 days gestation (term similar to 147 days); in 6 of these the ewe was given a single dose of betamethasone (11.4 mg im) 24 hr before delivery (LH + B). All lambs, including a control group (n = 6), were delivered at similar to 140 days and ventilated for 2 hr during which arterial pressures, pulmonary blood flow (PBF), and ventilating pressure and flow were recorded. During ventilation, respiratory system compliance was lower in both LH + B and LH groups than in controls. Pulmonary vascular resistance (PVR) was lower in LH + B lambs than in LH lambs and similar to controls; PBF was reduced in LH lambs but was restored to control levels by betamethasone. The mean density of small arteries of LH + B lambs was similar to that of LH lambs (P = 0.06) and lower than in controls; the thickness of the media of small pulmonary arteries from LH + B lambs was similar to that in LH lambs and thicker than in controls. VEGF mRNA levels were not different between groups. PDGF mRNA levels in LH + B lambs were higher than in LH lambs; a similar trend (P = 0.06) was seen for PECAM-1. SP-C mRNA levels were greater in both LH and LH + B lambs than in controls. Effects of betamethasone were greater on indices of pulmonary circulation than ventilation. We conclude that a single dose of maternal betamethasone 24 hr prior to birth has significant favorable effects on the postnatal adaptation of the pulmonary circulation in lambs with LH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Survival of bone marrow transplant recipients requiting mechanical ventilation is poor but improving. This study reports a retrospective audit of all haematopoietic stem cell transplant (HSCT) recipients requiring mechanical ventilation at an Australian institution over a period spanning 11 years from 1988 to 1998. Recipients of autologous transplants are significantly less likely to require mechanical ventilation than recipients of allogeneic transplants. Of 50 patients requiring mechanical ventilation, 28% survived to discharge from the intensive care unit, 20% to 30 days post-ventilation, 18% to discharge from hospital and 12% to six months post-ventilation. Risk factors for mortality in the HSCT recipient requiting mechanical ventilation include renal, hepatic and cardiovascular insufficiency and greater severity of illness. Mechanical ventilation of HSCT recipients should not be regarded as futile therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effect of standing with assistance of the tilt table on ventilatory parameters and arterial blood gases in intensive care patients. Design: Consecutive sample. Setting: Tertiary referral hospital. Participants: Fifteen adult patients who had been intubated and mechanically ventilated for more than 5 days (3 subjects successfully weaned, 12 subjects being weaned). Intervention: Passive tilting to 70degrees from the horizontal for 5 minutes using a tilt table. Main Outcome Measures: Minute ventilation (VE), tidal volume (VT), respiratory rate, and arterial partial pressure of oxygen (Pao(2)) and carbon dioxide (Paco(2)). Results: Standing in the tilted position for 5 minutes produced significant increases in VE (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the behavioural responses of two gobiid fish species to temperature to determine if differences in behaviour and ventilation rate might explain any apparent vertical zonation. A survey of the shore at Manly, Moreton Bay revealed Favonigobius exquisitus to dominate the lower shore and Pseudogobius sp. 4 the upper shore. These species were exposed to a range of temperatures (15-40 degreesC) in aquaria for up to 6 h. At 20 degreesC F. exquisitus exhibited a mean gill ventilation rate of 26 +/- 1.4 bpm (beats per minute) differing significantly from Pseudogobius, which ventilated at a fivefold greater rate of 143 +/- 6 bpm. The ventilation rate in F. exquisitus underwent a fivefold increase from normal local water temperature (20 degreesC) to high temperature (35 degreesC) conditions, whereas that of Pseudogobius did not even double, suggesting that Pseudogobius sp. is a better thermal regulator than F. exquisitus. While both species emerged from the water at high temperatures (>30 degreesC) the behaviours they exhibited while immersed at high temperature were quite different. F. exquisitus undertook vertical displacement movements we interpret as an avoidance response, whereas Pseudogobius sp. appeared to use a coping strategy involving movements that might renew the water mass adjacent to its body. The thermal tolerances and behaviours of F. exquisitus and Pseudogobius sp. are in broad agreement with their vertical distribution on the shore.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study objectives: Respiratory muscle weakness and decreased endurance have been demonstrated following mechanical ventilation. However, its relationship to the duration of mechanical ventilation is not known. The aim of this study was to assess respiratory muscle endurance and its relationship to the duration of mechanical ventilation. Design: Prospective study. Setting: Tertiary teaching hospital ICU. Patients: Twenty subjects were recruited for the study who had received mechanical ventilation for a 48 h and had been discharged from the ICU. Measurements: FEV1 FVC, and maximal inspiratory pressure (Pimax) at functional residual capacity were recorded. The Pimax attained following resisted inspiration at 30% of the initial Pimax for 2 min was recorded, and the fatigue resistance index (FRI) [Pimax final/Pimax initial] was calculated. The duration of ICU length of stay (ICULOS), duration of mechanical ventilation (MVD), duration of weaning (WD), and Charlson comorbidities score (CCS) were also recorded. Relationships between fatigue and other parameters were analyzed using the Spearman correlations (p). Results: Subjects were admitted to the ICU for a mean duration of 7.7 days (SD, 3.7 days) and required mechanical ventilation for a mean duration of 4.6 days (SD, 2.5 days). The mean FRI was 0.88 (SD, 0.13), indicating a 12% fall in Pimax, and was negatively correlated with MVD (r = -0.65; p = 0.007). No correlations were found between the FRI and FEV1, FVC, ICULOS, WD, or CCS. Conclusions: Patients who had received mechanical ventilation for > 48 h have reduced inspiratory muscle endurance that worsens with the duration of mechanical ventilation and is present following successful weaning. These data suggest that patients needing prolonged mechanical ventilation are at risk of respiratory muscle fatigue and may benefit from respiratory muscle training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study of ventilated patients investigated current clinical practice in 476 episodes of pneumonia (48% community-acquired pneumonia, 24% hospital-acquired pneumonia, 28% ventilator-associated pneumonia) using a prospective survey in 14 intensive care units (ICUs) within Australia and New Zealand. Diagnostic methods and confidence, disease severity, microbiology and antibiotic use were assessed. All pneumonia types had similar mortality (community-acquired pneumonia 33%, hospital-acquired pneumonia 37% and ventilator-associated pneumonia 24%, P = 0.15) with no inter-hospital differences (P = 0.08-0.91). Bronchoscopy was performed in 26%, its use predicted by admission hospital (one tertiary: OR 9.98, CI 95% 5.11-19.49, P < 0.001; one regional: OR 629, CI 95% 3.24-12.20, P < 0.001), clinical signs of consolidation (OR 3.72, CI 95% 2.09-662, P < 0.001) and diagnostic confidence (OR 2.19, CI 95% 1.29-3.72, P = 0.004). Bronchoscopy did not predict outcome (P = 0.11) or appropriate antibiotic selection (P = 0.69). Inappropriate antibiotic prescription was similar for all pneumonia types (11-13%, P = 0.12) and hospitals (0-16%, P = 0.25). Blood cultures were taken in 51% of cases. For community-acquired pneumonia, 70% received a third generation cephalosporin and 65% a macrolide. Third generation cephalosporins were less frequently used for mild infections (OR 0.38, CI 95% 0.16-0.90, P = 0.03), hospital-acquired pneumonia (OR 0.40, CI 95% 0.23-0.72, P < 0.01), ventilator-associated pneumonia (OR 0.04, CI 95% 0.02-0.13, P < 0.001), suspected aspiration (OR 0.20, CI 95% 0.04-0.92, P = 0.04), in one regional (OR 0.26, CI 95% 0.07-0.97, P = 0.05) and one tertiary hospital (OR 0.14, CI 95% 0.03-0.73, P = 0.02) but were more commonly used in older patients (OR 1.02, CI 95% 1.01-1.03, P = 0.01). There is practice variability in bronchoscopy and antibiotic use for pneumonia in Australian and New Zealand ICUs without significant impact on patient outcome, as the prevalence of inappropriate antibiotic prescription is low. There are opportunities for improving microbiological diagnostic work-up for isolation of aetiological pathogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smoke inhalation injuries are the leading cause of mortality from burn injury. Airway obstruction due to mucus plugging and bronchoconstriction can cause severe ventilation inhomogeneity and worsen hypoxia. Studies describing changes of viscoelastic characteristics of the lung after smoke inhalation are missing. We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen female Merino ewes were anesthetized and intubated. Baseline data using electrical impedance tomography and multiple-breath inert-gas washout were obtained by measuring ventilation distribution, functional residual capacity, lung clearance index, dynamic compliance, and stress index. Ten sheep were exposed to standardized cotton smoke insufflations and five sheep to sham smoke insufflations. Measured carboxyhemoglobin before inhalation was 3.87 +/- 0.28% and 5 min after smoke was 61.5 +/- 2.1%, range 50-69.4% ( P < 0.001). Two hours after smoke functional residual capacity decreased from 1,773 +/- 226 to 1,006 +/- 129 ml and lung clearance index increased from 10.4 +/- 0.4 to 14.2 +/- 0.9. Dynamic compliance decreased from 56.6 +/- 5.5 to 32.8 +/- 3.2 ml/ cmH(2)O. Stress index increased from 0.994 +/- 0.009 to 1.081 +/- 0.011 ( P < 0.01) ( all means +/- SE, P < 0.05). Electrical impedance tomography showed a shift of ventilation from the dependent to the independent lung after smoke exposure. No significant change was seen in the sham group. Smoke inhalation caused immediate onset in pulmonary dysfunction and significant ventilation inhomogeneity. The smoke inhalation device as presented may be useful for interventional studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in heart rate (f(H)) and cloacal ventilation frequency (f(C)) were investigated in the Fitzroy turtle, Rheodytes leukops, under normoxic (17.85 kPa) and hypoxic (3.79 kPa) conditions at 25 degrees C. Given R. leukops' high reliance on aquatic respiration via the cloacal bursae, the objective Of this Study was to examine the effect of varying aquatic PO2 levels upon the expression of a bradycardia in a freely diving, bimodally respiring turtle. In normoxia, mean diving f(H) and f(C) for R. leukops remained constant with increasing submergence length, indicating that a bradycardia failed to develop during extended dives of up to 3 days. Alternatively, exposure to aquatic hypoxia resulted in the expression of a bradycardia as recorded by a decreasing mean diving f(H) with increasing dive duration. The observed bradycardia is attributed to a hypoxic-induced metabolic depression, possibly facilitated by a concurrent decrease in f(C). Results suggest that R. leukops alters its strategy from aquatic O-2 extraction via cloacal respiration in normoxia to O-2 conservation when exposed to aquatic hypoxia for the purpose of extending dive duration. Upon surfacing, a significant tachycardia was observed for R. leukops regardless of aquatic PO2, presumably functioning to rapidly equilibrate blood and tissue gas tensions with alveolar gas to reduce surfacing duration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.