13 resultados para VALVES
em University of Queensland eSpace - Australia
Resumo:
Background. Human aortic valve allografts elicit a cellular and humoral immune response. It is not clear whether this is important in promoting valve damage. We investigated the changes in morphology, cell populations, and major histocompatibility complex antigen distribution in the rat aortic valve allograft. Methods. Fresh heart valves from Lewis rats were transplanted into the abdominal aorta of DA rats. Valves from allografted, isografted, and presensitized recipient rats were examined serially with standard morphologic and immunohistochemical techniques. Results. In comparison with isografts, the allografts were infiltrated and thickened by increased numbers of CD4(+) and CD8(+) lymphocytes, macrophages, and fibroblasts. Thickening of the valve wall and leaflet and the density of the cellular infiltrate was particularly evident after presensitization. Endothelial cells were frequently absent in presensitized allografts whereas isografts had intact endothelium. Cellular major histocompatibility complex class I and II antigens in the allograft were substantially increased. A long-term allograft showed dense fibrosis and disruption of the media with scattered persisting donor cells. Conclusions. The changes in these aortic valve allograft experiments are consistent with an allograft immune response and confirm that the response can damage aortic valve allograft tissue. (C) 1998 by The Society of Thoracic Surgeons.
Resumo:
Background and aim of the study: Results of valve re-replacement (reoperation) in 898 patients undergoing aortic valve replacement with cryopreserved homograft valves between 1975 and 1998 are reported. The study aim was to provide estimates of unconditional probability of valve reoperation and cumulative incidence function (actual risk) of reoperation. Methods: Valves were implanted by subcoronary insertion (n = 500), inclusion cylinder (n = 46), and aortic root replacement (n = 352). Probability of reoperation was estimated by adopting a mixture model framework within which estimates were adjusted for two risk factors: patient age at initial replacement, and implantation technique. Results: For a patient aged 50 years, the probability of reoperation in his/her lifetime was estimated as 44% and 56% for non-root and root replacement techniques, respectively. For a patient aged 70 years, estimated probability of reoperation was 16% and 25%, respectively. Given that a reoperation is required, patients with non-root replacement have a higher hazard rate than those with root replacement (hazards ratio = 1.4), indicating that non-root replacement patients tend to undergo reoperation earlier before death than root replacement patients. Conclusion: Younger patient age and root versus non-root replacement are risk factors for reoperation. Valve durability is much less in younger patients, while root replacement patients appear more likely to live longer and hence are more likely to require reoperation.
Resumo:
Objectives and Methods: Reoperations are an integral part of a cardiac surgeon's practice. We share our experience of 546 reoperations over the last 21 years to January 2000, with the focus directed towards the timing of reoperation, reducing the mortality and morbidity of reoperation and rereplacement aortic valve surgery, and understanding the important risk factors. In addition, the precise technical steps that facilitate careful successful explantation of various devices (allograft, stented and stentless xenografts, and mechanical valves) are detailed. Results: Optimal planned reoperation before deterioration to New York Heart Association Class III/IV levels and before unfavorable cardiac and comorbidity general system failure occurs has produced low mortality and morbidity as compared with first operation results. However, unfavorable delays and late rereferral result in mortality rates of up to 22% for emergency redo AVR for degenerated bioprostheses. Conclusion: Cardiac surgical units have the opportunity to establish a closer patient-surgeon relationship, which favors, when necessary, the optimal timing of reoperation. Knowledge of the more important risk factors and adherence to specific technical steps at explantation of various devices enhances satisfactory reoperation outcomes.
Resumo:
Biologic valve re-replacement was examined in a series of 1343 patients who underwent aortic valve replacement at The Prince Charles Hospital, Brisbane, with a cryopreserved or 4 degrees C stored allograft valve or a xenograft valve, A parametric model approach was used to simultaneously model the competing risks of death without re-replacement and re-replacement before death, One hundred eleven patients underwent a first re-replacement for a variety of reasons (69 patients with xenograft valves, 28 patients with 4 degrees C stored allograft valves, and 14 patients with cryopreserved allograft valves), By multivariable analysis younger age at operation was associated with xenograft, 4 degrees C stored allograft, and cryopreserved allograft valve re-replacement, However, this effect was examined in the context of longer survival of younger patients, which increases their exposure to the risk of re-replacement as compared with that in older patients whose decreased survival reduced their probability of requiring valve re-replacement, In patients older than 60 years at the time of aortic valve replacement, the probability of re-replacement (for any reason) before death was similar for xenografts and cryopreserved allograft valves but higher for 4 degrees C stored valves, However, in patients younger than 60 years, the probability of re-replacement at any time during the remainder of the life of the patient was lower with the cryopreserved allograft valve compared with the xenograft valve and 4 degrees C stored allografts.
Resumo:
Complete fetal bladder outlet obstruction was first diagnosed in a fetus at 13.5 weeks. After sequential vesico-centesis had shown good renal function, a vesico-amniotic shunt was inserted at 17 weeks with a Rodeck catheter. The procedure was successful and amniotic fluid volume re-accumulated to normal levels. A detailed scan at 20 weeks showed that the distal free end of the catheter was wound round the left fetal thigh. As the fetus grew, there was progressive constriction of the fetal thigh by the catheter. By 29 weeks, Doppler blood flow changes to the left leg were apparent. Fetoscopic surgery was performed at 30 weeks to release the constriction. The catheter was divided successfully, but the divided end of the shunt subsequently retracted into the fetal abdomen, producing urinary ascites, bilateral hydroureter and hydronephrosis. The baby was delivered at 31.5 weeks in good condition. Endoscopic resection of anterior and posterior urethral valves was performed at 6 months of age. At 2 years, the child has normal renal function, growth parameters and developmental milestones. Mild indentation of the left thigh was still apparent, although there was no functional impairment. Copyright (C) 2002 S. Karger AG, Basel.
Resumo:
Objective: Cardiac impairment is frequently found in babies of diabetic mothers. It is still controversial whether this is due to poor glucose control. The aim of this study is to compare the cardiac function in fetuses of well- and poorly-controlled pre-gestational diabetic pregnancy in third trimester. Methods:Women with type 1 pre-gestational diabetes were enrolled at 30-32 weeks. Cardiac size and interventricular septal wall thickness were measured by M-mode at end-diastolic phase. The right and left ventricular ejection fractions were calculated. At the mitral and tricuspid valves inflow, the ratio between early ventricular filling and active atrial filling (E/A) at both atrioventricular valves were measured by Doppler echocardiography. Peak velocities of ascending aorta and pulmonary artery were assessed. The angle of isonation was kept at 6.5%) were compared with those with satisfactorily controlled diabetes (HbA1c less than or equal to 6.5%). Results: A total of 21 women with pre-gestational diabetes were recruited for this study. Eight women with well-controlled diabetes were compared with 9 women who had poorly-controlled diabetes. HbA1c in the poorly-controlled group was 7.3% and in the well-controlled group it was 5.4% (p < 0.001). There was no difference between the two groups in cardiac size, interventricular septal wall thickness, ejection fraction, aorta and pulmonary artery peak flow velocities. The right atrioventricular E/A ratio was significantly lower among the poorly-controlled diabetic pregnancies (0.71 vs. 0.54; p < 0.05). Conclusion: Fetuses of poorly-controlled diabetic mothers had a lower right atrioventricular E/A ratio. This may be due to metabolic acidosis, non-hypertrophic cardiac dysfunction or fetal polycythemia. Copyright (C) 2003 S. Karger AG, Basel.
Resumo:
Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.
Resumo:
Objective To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. Design Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. Procedure All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. Results These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the maximising method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific normal left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. Conclusion These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.
Resumo:
Stem cells, either from embryonic or adult sources, have demonstrated the potential to differentiate into a wide range of tissues depending on culture conditions. This makes them prime candidates for use in tissue engineering applications. Current technology allows us to process biocompatible and biodegradable polymers into three-dimensional (3D) configurations, either as solid porous scaffolds or hydrogels, with controlled macro and/or micro spatial geometry and surface chemistry. Such control provides us with the ability to present highly controlled microenvironments to a chosen cell type. However, the precise microenvironments required for optimal expansion and/or differentiation of stem cells are only now being elucidated, and hence the controlled use of stem cells in tissue engineering remains a very young field. We present here a brief review of the current literature detailing interactions between stem cells and 3D scaffolds of varying morphology and chemical properties, concluding with remaining challenges for those interested in tissue engineering using tailored scaffolds and stem cells.
Resumo:
We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.
Resumo:
Kudoa monodactyli n. sp. is described from the somatic musculature of Monodactylus argenteus from several localities in southern Queensland, Australia. This is the first record of a myxozoan parasite from the family Monodactylidae. The spores typically have five polar capsules, making this species similar to the four other five-valved Kudoa species (K. neurophila, K. muscularis, K. shulmani, K. cutanea) that have been described to date. However, morphometric measurements particularly of spore length and width make the species from M. argenteus distinct from the other species. Comparison of the small subunit ribosomal DNA sequence of this species with its congeners for which sequence data are available, provides further evidence of novelty. Kudoa monodactyli n. sp. displays 38 (of 1,554) nucleotide differences compared with rDNA sequence of Kudoa neurophila, which on phylogenetic analysis places these species in clades exclusive of each other. Phylogenetic analyses also provide evidence that the number of valves per spore in this genus is an imperfect indicator of relatedness.
Resumo:
A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.