3 resultados para Tungsten

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tungsten oxide microtubules, arrayed in a radial flower-like structure, were synthesized by simply using W powders reacting with Ni(NO3)(2) center dot 6H(2)O at a elevated temperature. The formed microtubules, with lengths more than 100 pin and outer diameters of 1-5 mu m, have irregular open ends, showing clear grooves along the growth direction on the tubule surface. A novel aggregation mechanism based on chemical-vapor-deposit process was proposed to describe the growth process of the synthesized tubules, and the possible mechanism for the arrangement of the radial flower-like morphology was discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nano/micro grinding of tungsten carbide (WC) mould inserts was performed. A form accuracy of 〜200nm (in PV) and a surface roughness of 〜7nm were achieved. Nanoindentation revealed that small chipping or cracking occurred even at a penetration depth of 38nm, which could hinder the further improvement of surface quality during grinding. It was found that when grinding was conducted at nanometric scale, the microstructure of the work material and the morphology of the WC grains should be taken into account to enable a fully ductile removal. Copyright 2005 by the Japan Society of Mechanical Engineers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.