9 resultados para Tools for assessment

em University of Queensland eSpace - Australia


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Physical activity (PA) is relevant to the prevention and management of many health conditions in family practice. There is a need for an efficient, reliable, and valid assessment tool to identify patients in need of PA interventions. Methods: Twenty-eight family physicians in three Australian cities assessed the PA of their adult patients during 2004 using either a two- (2Q) or three-question (3Q) assessment. This was administered again approximately 3 days later to evaluate test-retest reliability. Concurrent validity was evaluated by measuring agreement with the Active Australia Questionnaire, and criterion validity by comparison with 7-day Computer Science Applications, Inc. (CSA) accelerometer counts. Results: A total of 509 patients participated, with 428 (84%) completing a repeat assessment, and 415 (82%) accelerometer monitoring. The brief assessments had moderate test-retest reliability (2Q k = 58.0%, 95% confidence interval [CI] = 47.2-68.8%; 3Q k = 55.6%, 95% CI = 43.8-67.4%); fair to moderate concurrent validity (2Q k = 46.7%, 95% CI = 35.657.9%; 3Q k = 38.7%, 95% CI = 26.4-51.1%); and poor to fair criterion validity (2Q k = 18.2%, 95% CI = 3.9-32.6%; 3Q k = 24.3%, 95% CI = 11.6-36.9%) for identifying patients as sufficiently active. A four-level scale of PA derived from the PA assessments was significantly correlated with accelerometer minutes (2Q rho = 0.39, 95% CI = 0.28-0.49; 3Q rho = 0.31, 95% CI = 0.18-0.43). Physicians reported that the assessments took I to 2 minutes to complete. Conclusions: Both PA assessments were feasible to use in family practice, and were suitable for identifying the least active patients. The 2Q assessment was preferred by clinicians and may be most appropriate for dissemination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objective: Estimates of dietary folate intake are currently of considerable interest, but no rapid tools are available to assess dietary intake of folate that are well suited to everyday health promotion activities, We developed and tested the reliability and validity of two prototypes of a rapid dietary assessment tool (a folate intake tool, FIT) to determine dietary intake of folate. Study Design and Setting: Five hundred and sixty eight men and women aged 33-93 years from Perth, Western Australia. Completed one of the two prototypes of the tool and gave a fasting blood sample for measurement of serum folate. A subset (n - 277) of participants completed the same tool on a second occasion 3-6 weeks later. Results: The Pearson correlations (r) between folate score from the tool and serum folate were moderately high for both prototypes (FIT-A r = 0.54-, FIT-B r = 0.49). The folate scores for the two prototypes were similar on repeat testing and correlated strongly (FIT-A r = 0.75; FIT-B r = 0.68). Conclusions: The rapid dietary assessment tool described here, FIT, provides a valid and reliable measurement of dietary intake of folate for both men and women. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prediction of regulatory elements is a problem where computational methods offer great hope. Over the past few years, numerous tools have become available for this task. The purpose of the current assessment is twofold: to provide some guidance to users regarding the accuracy of currently available tools in various settings, and to provide a benchmark of data sets for assessing future tools.