66 resultados para Test facilities

em University of Queensland eSpace - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of scramjet propulsion for alternative launch and payload delivery capabilities has been composed largely of ground experiments for the last 40 years. With the goal of validating the use of short duration ground test facilities, a ballistic reentry vehicle experiment called HyShot was devised to achieve supersonic combustion in flight above Mach 7.5. It consisted of a double wedge intake and two back-to-back constant area combustors; one supplied with hydrogen fuel at an equivalence ratio of 0.34 and the other unfueled. Of the two flights conducted, HyShot 1 failed to reach the desired altitude due to booster failure, whereas HyShot 2 successfully accomplished both the desired trajectory and satisfactory scramjet operation. Postflight data analysis of HyShot 2 confirmed the presence of supersonic combustion during the approximately 3 s test window at altitudes between 35 and 29 km. Reasonable correlation between flight and some preflight shock tunnel tests was observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The in situ real time measurement of the regression rate of a melting interface (RRMI) is performed by the ultrasonic measurement system reported here. The RRMI is the rate at which a solid/liquid interface (SLI) moves along a metallic rod while burning in an oxygen-enriched atmosphere and is an important flatnmability indicator. The ultrasonic transducer and associated equipment used to drive the transducer and record the echo signal is described, along with the process that transforms the acquired signals into a RRMI value. Test rods of various metals and geometric shapes were burned at several test conditions in different test facilities. The RRMI results with quantified errors are presented and reviewed. The effect of reduced gravity on burning metals is important to space-applications and RRMI results obtained in a reduced gravity environment are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A free-piston driver that employs entropy-raising shock processes with diaphragm rupture has been constructed, which promises significant theoretical advantages over isentropic compression. Results from a range of conditions with helium and argon driver gases are reported. Significant performance gains were achieved in some test cases. Heat losses are shown to have a strong effect on driver processes. Measurements compare well with predictions from a quasi-one-dimensional numerical code.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two force balance techniques for use in hypersonic impulse facilities are compared by measuring the drag force on a 30° semi-apex-angle blunt cone model in a hypersonic shock tunnel at a free stream Mach number of 5.75. An accelerometer-based balance and a stress-wave force balance were tested simultaneously on the same model to measure the drag force. It was found that drag force measurements could be made using both techniques in a flow with a 450-μ s test period. The measured drag forces compared well with the theoretical values estimated using Newtonian theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The calculation of quantum dynamics is currently a central issue in theoretical physics, with diverse applications ranging from ultracold atomic Bose-Einstein condensates to condensed matter, biology, and even astrophysics. Here we demonstrate a conceptually simple method of determining the regime of validity of stochastic simulations of unitary quantum dynamics by employing a time-reversal test. We apply this test to a simulation of the evolution of a quantum anharmonic oscillator with up to 6.022×1023 (Avogadro's number) of particles. This system is realizable as a Bose-Einstein condensate in an optical lattice, for which the time-reversal procedure could be implemented experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expansion tubes are impulse facilities capable of generating highly energetic hyper-sonic flows. This work surveys a broad range of flow conditions produced in the facility X1 with carbon dioxide test gas, for simulation of spacecraft entry into the Martian atmosphere. Conditions with nominal flow speeds of 7, 9, 11 and 13 km/s were tested. The freestream conditions were calibrated using static/Pitot pressure measurements and advanced optical diagnostics. An extensive set of holographic interferometry experiments was performed on flows over wedges for quantitative study of freestream and post-shock densities, and post-shock ionisation. A one-dimensional code with frozen and equilibrium chemistry capabilities was used to estimate the freestream conditions. An equilibrium chemistry model produced a good match to measured freestream quantities at the high enthalpy conditions which are a major aim of this facility's operation. The freestream in the lower enthalpy conditions was found to be heavily influenced by chemical non-equilibrium. Non-equilibrium in the final unsteady expansion process of flow generation was accounted for by switching from equilibrium to frozen chemistry at a predetermined point. Comparison between the freestream density results of holographic interferometry, pressure measurements and computations shows good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Force measurement in hypervelocity expansion tubes is not possible using conventional techniques. The stress wave force balance technique can be applied in expansion tubes to measure forces despite the short test times involved. This paper presents a new calibration technique for multiple-component stress wave force balances where an impulse response created using a load distribution is required and no orthogonal surfaces on the model exist.. This new technique relies on the tensorial superposition of single-component impulse responses analogous to the vectorial superposition of the calibration loads. The example presented here is that of a scale model of the Mars Pathfinder, but the technique is applicable to any geometry and may be useful for cases where orthogonal loads cannot be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although morphine-6-glucuronide (M6G) has been shown to be analgesically active, the relative involvement of spinal and supraspinal structures in mediating M6G's pain-relieving effects following central and systemic administration to rats is unclear. As the tail flick and hotplate latency tests are reported to quantify antinociception mediated primarily by spinal and supraspinal mechanisms respectively, these methods were used to determine the comparative apparent levels of antinociception (expressed as percentage maximum possible effect, % MPE) achieved after M6G or morphine administration. Following i.v. or i.p. M6G (1.9-5.4 mu mol) dosing or i.p. morphine (10 mu mol) dosing, high levels of antinociception (>50% MPE) were achieved using the tail flick test whereas base-line levels of antinociception were observed 30 sec later in the same rats using the hotplate test. By contrast, antinociception evoked by i.v. morphine (10 mu mol) exceeded 50% MPE using both the hotplate and tail flick tests although the apparent potency was approximately 2.5 times greater using the tail flick test. After i.c.v. dosing, M6G (0.22-3.3 nmol) was significantly (P < .05) more potent when assessed using the tail flick compared with the hotplate test. Taken together, these data strongly indicate that following central and systemic administration, M6G's antinociceptive effects are mediated primarily by spinal structures whereas both spinal and supraspinal mechanisms contribute to systemic morphine's antinociceptive effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To investigate the test-retest stability of a standardized version of Nelson's (1976) Modified Card Sorting Test (MCST) and its relationships with demographic variables in a sample of healthy older adults. Design. A standard card order and administration were devised for the MCST and administered to participants at an initial assessment, and again at a second session conducted a minimum of six months later in order to examine its test-retest stability. Participants were also administered the WAIS-R at initial assessment in order to provide a measure of psychometric intelligence. Methods. Thirty-six (24 female, 12 male) healthy older adults aged 52 to 77 years with mean education 12.42 years (SD = 3.53) completed the MCST on two occasions approximately 7.5 months (SD = 1.61) apart. Stability coefficients and test-retest differences were calculated for the range of scores. The effect of gender on MCST performance was examined. Correlations between MCST scores and age, education and WAIS-R IQs were also determined. Results. Stability coefficients ranged from .26 for the percent perseverative errors measure to .49 for the failure to maintain set measure. Several measures were significantly correlated with age, education and WAIS-R IQs, although no effect of gender on MCST performance was found. Conclusions. None of the stability coefficients reached the level required for clinical decision making. The results indicate that participants' age, education, and intelligence need to be considered when interpreting MCST performance. Normative studies of MCST performance as well as further studies with patients with executive dysfunction are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This note considers the value of surface response equations which can be used to calculate critical values for a range of unit root and cointegration tests popular in applied economic research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We find that prospect theory behavior is significantly more prevalent than utility theory behavior in experiments involving multiple, real items. In the experiments, subjects were endowed with three items and asked the minimum payments they required to be willing to return one, two, or three of them. Our key observation is that prospect theory implies concavity of compensation demanded, whereas utility theory implies convexity. We examine whether the compensation demanded is convex or concave in the number of items returned. (JEL C91).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of a positive genetic correlation between male and female components of mate recognition systems will result as a consequence of assortative mating and, in particular, is central to a number of theories of sexual selection. Although the existence of such genetic correlations has been investigated in a number of taxa, it has yet to be shown that such correlations evolve and whether they may evolve as rapidly as suggested by sexual selection models. In this study, I used a hybridization experiment to disrupt natural mate recognition systems and then observed the subsequent evolutionary dynamics of the genetic correlation between male and female components for 56 generations in hybrids between Drosophila serrata and Drosophila birchii. The genetic correlation between male and female components evolved from 0.388 at generation 5 to 1.017 at generation 37 and then declined to -0.040 after a further 19 generations. These results indicated that the genetic basis of the mate recognition system in the hybrid populations evolved rapidly. The initial rapid increase in the genetic correlation was consistent with the classic assumption that male and female components will coevolve under sexual selection. The subsequent decline in genetic correlation may be attributable to the fixation of major genes or, alternatively, may be a result of a cyclic evolutionary change in mate recognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on a sample of normal Australian elderly who were assessed for naming ability using the Boston Naming Test (BNT). The study aimed to examine and compare the changes in naming ability, using both longitudinal and cross-sectional analysis, and determine the relationships between naming ability and age, educational level, visual acuity and gender and cultural relevance. Contradictory findings were produced regarding age and were dependent on the research design. Longitudinal analysis showed no age-related change in naming ability in subjects over a four-period. In contrast, cross-sectional analysis showed a weak but significant correlation between age and naming ability. Educational level, visual acuity and gender were unrelated to changes in naming ability over time, and unrelated to naming ability across the cohort of elderly. The Australian elderly performed better on the modified Australian version of the BNT than on the original American version. Thus, clinicians need to be cautious when interpreting the results of the BNT for elderly and for populations outside North America. The results of this study also indicate a need for further longitudinal research of a greater duration to establish age-related decline in naming ability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine whether the Hopkins Verbal Learning Test (HVLT) could be used as a valid and reliable screening test for mild dementia in older people, and to compare its performance to that of the Mini-Mental State Examination (MMSE). Method. Using a cross-sectional design, we studied three groups of older subjects recruited from a district geriatric psychiatry service: (1) 26 patients with DSM-IV dementia and MMSE scores of 18 or better; (2) 15 patients with psychiatric diagnoses other than dementia; and (3) 15 normal controls. The relationship of each potential cutting point on the HVLT and the MMSE was examined against the independently ascertained DSM-IV diagnoses of dementia using a Receiver Operating Characteristic (ROC) analysis. Results. The subjects consisted of 21 (37.5%) males and 35 (62.5%) females with a mean age of 74.7 (SD 6.1) years and a mean of 8.5 (SD 1.8) years of formal education. ROC analysis indicated that the optimal cutting point for detecting mild dementia in this group of subjects using the HVLT was 18/19 (sensitivity = 0.96, specificity = 0.80) and using the MMSE was 25/26 (sensitivity = 0.88, specificity = 0.93). Conclusions. The HVLT can be recommended as a valid and reliable screening test for mild dementia and as an adjunct in the clinical assessment of older people. The HVLT had better sensitivity than the MMSE in detecting patients with mild dementia, whereas the MMSE had better specificity. Copyright (C) 2000 John Wiley & Sons, Ltd.