2 resultados para TOTAL COMPLETION-TIME
em University of Queensland eSpace - Australia
Resumo:
Objectives: To investigate the effectiveness of valerian for the management of chronic insomnia in general practice. Design: Valerian versus placebo in a series of n-of-1 trials, in Queensland, Australia. Results: Of 42 enrolled patients, 24 (57%) had sufficient data for inclusion into the n-of-1 analysis. Response to valerian was fair for 23 (96%) participants evaluating their 'energy level in the previous day' but poor or modest for all 24 (100%) participants' response to 'total sleep time' and for 23 (96%) participants' response to 'number of night awakenings' and 'morning refreshment'. As a group, the proportion of treatment successes ranged from 0.35 (95% CI 0.23, 0.47) to 0.55 (95% CI 0.43, 0.67) for the six elicited outcome sleep variables. There was no significant difference in the number (P = 0.06), distribution (P = 1.00) or severity (P = 0.46) of side effects between valerian and placebo treatments. Conclusions: Valerian was not shown to be appreciably better than placebo in promoting sleep or sleep-related factors for any individual patient or for all patients as a group. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.